TEXAS STATE FIRE MARSHAL'S OFFICE <br />FIRE SAFETY INSPECTION REPORT <br />The fire extinguishers did not have the required annual inspection, the last inspection dates <br />were 2010 and 2004. <br />NFPA 1, Fire Code, Chapter 4.5.8.1 <br />VIOLATION 13 <br />The stairwell lacks stairwell signage. <br />The lack of approved stairway signage could cause occupant confusion in an emergency <br />evacuation. <br />(NORTH STAIN <br />L_--.I <br />9 <br />SUB - BASEMENT TO 29TH FLOOR <br />NO ROOF ACCESS <br />DOWN TO FIRST FLOOR <br />FOR EXIT DISCHARGE <br />Recommended stair sign <br />Existing enclosed stairs serving five or more stories shall comply with the following criteria: <br />A. The stairs shall be provided with special signage within the enclosure at each floor <br />landing. <br />B. The signage shall indicate the floor level. <br />C. The signage shall indicate the terminus of the top and bottom of the stair enclosure. <br />D. The signage shall indicate the identification of the stair enclosure. <br />E. The signage shall indicate the floor level of, and the direction to, exit discharge. <br />F. The signage shall be located inside the enclosure approximately 60 in. (1525 mm) above <br />the floor landing in a position that is visible when the door is in the open or closed <br />position. <br />G. The signage shall comply with 14.14.8.1 and 14.14.8.2 of this Code. <br />H. The floor level designation shall also be tactile in accordance with ICC /ANSI Al 17.1, <br />American National Standard for Accessible and Usable Buildings and Facilities. <br />I. The signage shall be painted or stenciled on the wall or on a separate sign securely <br />attached to the wall. <br />Inspection Number RROI 5800A Page 4 of 5 <br />Revised 12/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.