My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-026 - Amending Section 7-16 and 7-18 of Article II Building Code, Chapter 7, Buildings and Building Regulations ....
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2017
>
2017-026 - Amending Section 7-16 and 7-18 of Article II Building Code, Chapter 7, Buildings and Building Regulations ....
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2017 11:13:17 AM
Creation date
7/12/2017 11:08:59 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - Date
7/10/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3005.7.2.1 Prohibited locations. Automatic sprinklers shall not be installed in machine rooms, <br />elevator machinery spaces, control rooms, control spaces and elevator hoist -ways. <br />3005.7.2.2 Sprinkler system monitoring. The sprinkler system shall have a sprinkler control <br />valve supervisory switch and water -flow initiating device provided for each floor that is monitored <br />by the building's fire alarm system. <br />3005.7.3 Water protection. An approved method to prevent water from infiltrating into the <br />hoistway enclosure from the operation of the automatic sprinkler system outside the elevator <br />lobby shall be provided. <br />3005.7.4 Shunt trip. Means for elevator shutdown in accordance with Section 3005.5 shall not be <br />installed. <br />Section 3005, MACHINE ROOMS, shall be amended by adding Section 3005.8, Storage, to read as <br />follows: <br />3005.8 Storage. Storage shall not be allowed within the elevator machine room, control room, machinery <br />spaces and or control spaces. Provide approved signage at each entry to the above listed locations <br />stating: "No Storage Allowed. <br />Section 3006.2, Hoistway opening protection required, shall be amended by amending subparagraph 5. <br />to read as follows: <br />3006.2 Hoistway opening protection required. .. . <br />5. The building is a high rise and the elevator hoistway is more than 76 feet (22 860 FnFn4 55 feet (16 764 <br />mm ) in height. The height of the hoistway shall be measured from the lowest floor at or above grade to <br />the highest floors served by the hoistway. <br />Section 3109. 1, General, shall be amended to read as follows: <br />3109.1 General. Swimming pools shall comply with the requirements of sections 3109.2 through 3109.5 <br />and other applicable sections of this code and complying with applicable state laws. <br />16 2015 IBC Amendments <br />