open -sided walking surfaces, including <br />mezzanines, equipment platforms, aisles, stairs, ramps and landings that are and is not provided with <br />guards, or those in which the existing guards are judged to be in danger of collapsing, shall be provided <br />with guards. <br />Section 804. 1, Scope, shall be amended to read as follows: <br />804.1 Scope. The requirements of this section shall be limited to work areas in which Level 2 alterations <br />are being performed, and where specified they shall apply throughout the floor on which the work areas are <br />located or otherwise beyond the work area. For the purpose of fire sprinkler protection and fire alarm <br />requirements included in this section, the work area shall be extended to include at least the entire tenant <br />space or spaces bounded by walls capable of resisting the passage of smoke containing the subject work <br />area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or <br />other exit access shall be protected in its entirety on that particular floor level. <br />Section 804.2.2, Groups A, B, E, F -1, H,1, M, R -1, R -2, R-4, S -1 and S -2, shall be amended to change the <br />Exception to Item 2. to read as follows: <br />804.2.2 Groups A, B, E, F -1, H, I, M, R -1, R -2, R-4, S -1 and S -2. .. . <br />2. ... <br />Exception: 4f-Where the building does not have sufficient municipal water supply for design of a <br />fire sprinkler system available to the floor without installation of a new fire pump, fire sprinkler <br />protection shall not be required <br />system thMugheut all GGGUPiable spaGes other than sleepiRg units 9F individual dwelling units that <br />aGthyates the ersrupan R9tifiGatiOR system on aeGerdaRGe with Se6tions 907.4, 907.5 and 907.6 of <br />the IntemationalBuWin Code. <br />Section 804.2.5, Supervision, shall be amended to change the Exception to read as follows: <br />804.2.5 Supervision. .. . <br />Exception: Supervision is not required where the Fire Code does not require such for new <br />construction. fer the #ellewig <br />1 - UndeFgreund gate valve With roadway boxes. <br />7 Halogenated extinguishing systems <br />3 Garhon dioxide extinguishing c. stem <br />A P1n, and wet ehemieal extinguishing systems. <br />main is used to supply both demeStiG and autwnatiG 6PF!RkleF systeMS and a sepaFate ShUteff <br />Section 804.3, Standpipes, shall be amended to read as follows: <br />804.3 Standpipes. Refer to Section 1103.6 of the Fire Code for retroactive standpipe reauirements. <br />(Delete remainder of Section 804.3, including Exceptions) <br />Section 805.2, General, shall be amended to delete Exception V. <br />805.2 General. .. . <br />Exceptions: <br />1. he a the a erL a and them of egress seFViRg it GOMplies with NFRA40 <br />2. (Exception 2 remains unchanged.} <br />Section 805.3.1.1, Single -exit buildings, shall be amended to delete Item 4.: <br />805.3.1.1. Single -exit buildings. {Paragraph remains unchanged.} ... <br />3 2015 IEBC Amendments <br />