Laserfiche WebLink
(7.5 psi), the test pressure shall be not less than one and one -half times the proposed maximum working <br />pressure. <br />Diaphragm gauges used for testing must display a current calibration and be in good working condition. <br />The appropriate test must be applied to the diaphragm gauqe used for testing <br />Section G2417.4.2 (406.4.2), Test duration, shall be amended to read as follows: <br />G2417.4.2 (406.4.2) Test duration. The test duration shall be held for a length of time satisfactory to the <br />Building Official, but in no case for be flet less than 44D-fifteen (15) minutes. For welded piping, and for <br />piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa ), the <br />test duration shall be held for a length of time satisfactory to the Building Official, but in no case for less <br />than thirty (30) minutes. <br />Section G2420.1 (409. 1), General, shall be amended by adding Section G2420.1.4, Valves in CSST <br />installations, to read as follows: <br />G2420.1.4 Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST) <br />piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for <br />the size of the valves, of adequate strength and guality, and located at intervals so as to prevent or damp <br />out excessive vibration but in no case greater than 12- inches from the center of the valve. Supports shall <br />be installed so as not to interfere with the free expansion and contraction of the system's piping fittings <br />and valves between anchors. All valves and supports shall be designed and installed so they will not be <br />disengaged by movement of the supporting piping <br />Section G2420.5.1 (409.5.1), Located within the same room, shall be amended to read as follows: <br />G2420.5.1 (409.5.1) Located within the same room. The shutoff valve shall be located in the same <br />room as the appliance. The shutoff valve shall be within 6 feet (1829 mm) of the appliance, and shall be <br />installed upstream of the union, connector or quick disconnect device it serves. Such shutoff valves shall <br />be provided with access. Appliance shutoff valves located in the firebox of a fireplace shall be installed in <br />accordance with the appliance manufacturer's instructions. A secondary shutoff valve must be installed <br />within 3 feet (914 mm) of the firebox if appliance shutoff is located in the firebox. <br />Section G2421.1(410.1); Pressure regulators, shall be amended to read as follows: <br />G2421.1 (410.1) Pressure regulators. A line pressure regulator shall be installed where the appliance is <br />designed to operate at a lower pressure than the supply pressure. Line gas pressure regulators shall be <br />listed as complying with ANSI Z21.80. Access shall be provided to pressure regulators. Pressure <br />regulators shall be protected from physical damage. Regulators installed on the exterior of the building <br />shall be approved for outdoor installation. Access to regulators shall comply with the requirements for <br />access to appliances as specified in Section M1305. <br />Exception: A passageway or level service space is not required when the regulator is capable of <br />being serviced and removed through the required attic opening. <br />Section G2422.1.2.3 (411.1.3.3), Prohibited locations and penetrations, shall be amended to delete <br />Exceptions 1 and 4 in their entirety. <br />Section G2445.2 (621.2), Prohibited use, shall be amended to read as follows: <br />G2445.2 (621.2) Prohibited use. One or more unvented room heaters shall not be used as the sole <br />source of comfort heating in a dwelling unit. <br />Exception: Existing approved unvented room heaters may continue to be used in dwelling units in <br />accordance with the code provisions in effect when installed when approved by the Building Official <br />unless an unsafe condition is determined to exist as described in International Fuel Gas Code Section <br />108.7 of the Fuel Gas Code. <br />Section G2448.1.1 (624.1.1), Installation requirements, shall be amended to read as follows: <br />2015 IRC Amendments <br />