potable water supply through cross - connections or any other piping connections to the system. Backflow <br />preventer applications shall conform to applicable local regulations. Table 608.1, except and as <br />specifically stated in Sections 608.2 through 608.16.10. <br />Section 608.16.5, Connections to lawn irrigation systems, shall be amended to read as follows: <br />608.16.5 Connections to lawn irrigation systems. <br />The potable water supply to lawn irrigation systems shall be protected against backflow by an <br />atmospheric -type vacuum breaker, a pressure -type vacuum breaker, a double -check assembly or a <br />reduced pressure principle backflow preventer. A valve shall not be installed downstream from an <br />atmospheric vacuum breaker. Where chemicals are introduced into the system, the potable water supply <br />shall be protected against backflow by a reduced pressure principle backflow preventer. <br />Section 608.17, Protection of individual water supplies, shall be amended to read as follows: <br />608.17 Protection of individual water supplies. An individual water supply shall be located and <br />constructed so as to be safeguarded against contamination in accordance with applicable local <br />regulations. Installation shall be in accordance with Sections 608.17.1 through 608.17.8. <br />Section 610. 1, General, shall be amended to read as follows: <br />610.1 General. New or repaired potable water systems shall be purged of deleterious matter and <br />disinfected prior to utilization. The method to be followed shall be that prescribed by the health authority <br />or water purveyor having jurisdiction or, in the absence of a prescribed method, the procedure described <br />in either AWWA C651 or AWWA C652, or as described in this section. This requirement shall apply to <br />"on- site" or "in- plant' fabrication of a system or to a modular portion of a system. <br />1. The pipe system shall be flushed with clean, potable water until dirty water does not appear at the <br />points of outlet. <br />2. The system or part thereof shall be filled with a water /chlorine solution containing at least 50 parts <br />per million (50 mg /L) of chlorine, and the system or part thereof shall be valved off and allowed to <br />stand for 24 hours; or the system or part thereof shall be filled with a water /chlorine solution <br />containing at least 200 parts per million (200 mg /L) of chlorine and allowed to stand for 3 hours. <br />3. Following the required standing time, the system shall be flushed with clean potable water until <br />the chlorine is purged from the system. <br />4. The procedure shall be repeated where shown by a bacteriological examination that <br />contamination remains present in the system. <br />Exception: With prior approval the Code Official may wave this requirement when deemed <br />un- necessary. <br />Section 703.6, Combined sanitary and storm public sewer, shall be deleted in its entirety. <br />Section 704, DRAINAGE PIPING INSTALLATION, shall be amended by adding Section 704.5, <br />Single stack fittings, to read as follows: <br />704.5 Single stack fittings. Single stack fittings with internal baffle PVC schedule 40 or cast iron single <br />stack shall be designed by a registered engineer and comply to a national recognized standard <br />Section 705.11.2, Solvent cementing, shall be amended to read as follows: <br />5 Amendments to 2015 IPC <br />