Laserfiche WebLink
`1. Final construction plans, with detailed drainage plan, with minimum finished floor <br />elevations for each lot in the subdivision, with a title sheet affixed thereto, <br />containing the name of the subdivision, the developer and the registered <br />professional engineer preparing the plans, with his seal affixed, and a vicinity map <br />showing the location of the subdivision. <br />`2. Plan -profile sheets of all proposed streets. These sheets are to be 22" x 36" in size <br />and plotted to scale of one inch to one hundred (100) feet horizontal and one inch <br />to five (5) feet vertical. These plan -profiles shall show the right-of-way of the <br />street, portions of the right-of-way of intersecting streets, location of curb and <br />gutter with respect to monuments, curb return radii, dips or valleys, soil type, <br />liquid limit and plasticity index for each major soil type encountered at the <br />subgrade level, test locations and estimated boundaries between soil types in the <br />plan portion. Accompanying the plan portion must be the certified test results <br />performed by an independent testing laboratory approved by the City of Paris <br />which verifies the information required and furnished. The profile shall show the <br />existing ground on each side of the street at the right-of-way line, the proposed <br />grade of the top of the curb for each side of the street, and the reference bench <br />mark with its elevation. These plan -profiles shall show or be accompanied by a <br />typical cross section of the proposed street or streets to be constructed, <br />"3. All utility plans (sanitary sewer, water, storm sewer, culverts and bridges) shall be <br />on sheets 22" x 36" and shall show all information necessary for their <br />construction. These plans shall be accompanied by the Engineer's criteria and <br />calculations for their design. All designs must meet all aforesaid City, State and <br />Federal minimum specifications. <br />"4. Prior to the construction of any proposed improvements, i.e. streets, drainage, <br />utilities, etc., the subdivider shall furnish complete plans and specifications of said <br />construction to the City Engineer, If any part of the proposed construction is <br />considered unsatisfactory by him and below the standards required under the <br />circumstances, construction operations shall not be started on the affected portion <br />until alterations are made such that the completed work shall conform to the <br />standards required by the City of Paris. The City Engineer shall be notified prior to <br />beginning construction so that he or his duly authorized representative may <br />inspect said work on the behalf of the City during the construction. <br />"5. Upon the completion ®f construction of any such improvements, the subdivider <br />shall furnish a final set of plans in detail to the City Engineer. These plans shall be <br />certified by the Engineer preparing the to be complete and correct "as built" <br />plans of the improvements and where applicable shall bear the statement "Built <br />under my supervision" and signed by the Engineer." <br />Section 3. That all provisions of the ordinances of the City of Paris, Texas in conflict <br />with the provisions of this ordinance are hereby repealed, and all other provisions of the <br />ordinances of the City of Paris not in conflict with the provisions of this ordinance shall <br />remain in full force and effect. <br />