My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13-15 - Local Amendments to the Building Code, Fire Code and Plumbing Code
City-of-Paris
>
City Council
>
Agenda Packets
>
2011-2020
>
2020
>
10 - OCTOBER
>
October 12
>
13-15 - Local Amendments to the Building Code, Fire Code and Plumbing Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2020 3:57:31 PM
Creation date
10/8/2020 3:54:49 PM
Metadata
Fields
Template:
AGENDA
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"503.4 Obstruction of Fire Apparatus Access Roads. Fire apparatus <br />access roads shall not be obstructed in any manner, including the parking of <br />vehicles. The minimum widths and clearances established in Section 503.2.1 <br />and any area marked as a fire lane as described in Section 503.3 shall be <br />maintained at all times." <br />Section 505.1, Address identification, shall be amended to read as follows: <br />"505.1 Address Identification. New and existing buildings shall be <br />provided with approved address identification. The address identification <br />shall be legible and placed at the top corner of the building in a position that is <br />visible from the street or road fronting the property. Address identification <br />characters shall contrast with their background. Addresses numbers shall be <br />Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each <br />character shall be not less than 6 12 inches (192.4 304.8 mm) high with a <br />minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code <br />official, address numbers shall be provided in additional approved locations <br />to facilitate emergency response. Within a shopping center the ...addre_ss <br />identification of leased space or suite with its own address shall be in <br />characters that are .minimum of..6 inches.1.52..4.umm...with._a minimum stroke <br />widthw of/ inch , 12.7 mm and shall be located above or on the suite door. <br />Each character in a suite number shall be a minimum of 4 inches ('101.6 mm;) <br />hi )h with a minimum stroke width of � inch 12.7 mm and shall be located <br />above or on the _suite _door. _µWhere access is by means of a private road, <br />buildings do not immediately front a street, and/or the building cannot be <br />viewed from the public way, a monument, pole or other sign with approved 6 <br />12 inch (152:4 304.8 mm) height building numerals or addresses and 4 inch <br />(101.6 mm) height suite/apartment numerals of a color contrasting with the <br />background of the building or other approved means shall be used to identify <br />the structure. Numerals or addresses shall be posted on a minimum 20 inch <br />(508 mm) by 30 inch (762 mm) background on border. Address identification <br />shall be maintained. <br />"Exception: R-3 Single Family occupancies shall have approved <br />numerals of a minimum 3 Ih inches (88.9 mm) in height and a color <br />contrasting with the background clearly visible and legible from the <br />street fronting the property and rear alleyway where such alleyway <br />exists." <br />Section 506.1, Where required, shall be amended to add section 506.1.3, to read <br />as follows: <br />"506.1.3. An approved key box shall be provided on each <br />nonresidential occupancy with a fire alarm system or fire sprinkler system. <br />The key box shall contain keys for each locked doorway within the buildings <br />14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.