My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13-15 - Local Amendments to the Building Code, Fire Code and Plumbing Code
City-of-Paris
>
City Council
>
Agenda Packets
>
2011-2020
>
2020
>
10 - OCTOBER
>
October 12
>
13-15 - Local Amendments to the Building Code, Fire Code and Plumbing Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2020 3:57:31 PM
Creation date
10/8/2020 3:54:49 PM
Metadata
Fields
Template:
AGENDA
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"7. When required by this Chapter, standpipe connections shall be <br />placed adjacent to all required exits to the structure and at two <br />hundred feet (200') intervals along major corridors thereafter, or <br />as otherwise approved by the fire code official." <br />Section 905.9, Valve supervision, shall be amended to add a second paragraph <br />after the exceptions to read as follows: <br />"Sprinkler and standpipe system water -flow detectors shall be <br />provided for each floor tap to the sprinkler system and shall cause an alarm <br />upon detection of water flow for more than 45 seconds. All control valves in <br />the sprinkler and standpipe systems except for fire department hose <br />connection valves shall be electrically supervised to initiate a supervisory <br />signal at the central station upon tampering." <br />Section 907.1, General, shall be amended to add Section 907.1.4, Design <br />standards, to read as follows: <br />"907.1.4 Design Standards. Where a new fire alarm system is <br />installed, the devices shall be addressable. Fire alarm systems utilizing more <br />than 20 smoke detectors shall have analog initiating devices." <br />Section 907.2.1, Group A, shall be amended to read as follows: <br />"907.2.1 Group A. A manual fire alarm system that activates the <br />occupant notification system in accordance with Section 907.5 shall be <br />installed in Group A occupancies having an occupant load of 300 or more <br />persons or more than 100 persons above or below the lowest level of exit <br />discharge. Group A occupancies not separated from one another in <br />accordance with Section 707.3.-10 of the International Building Code shall be <br />considered as a single occupancy for the purposes of applying this section. <br />Portions of Group E occupancies occupied for assembly purposes shall be <br />provided with a fire alarm system as required for the Group E occupancy. <br />"Exception. Manual fire alarm boxes are not required where the <br />building is equipped throughout with an automatic sprinkler system <br />installed in accordance with Section 903.3.1.1 and the occupant <br />notification appliances will activate throughout the notifications upon <br />sprinkler water flow. <br />"Activation of fire alarm notification appliances shall: <br />"1. Cause illumination of the means of egress with light of not less than <br />1 foot-candle (11 lux) at the walking surface level, and <br />"2. Stop any conflicting or confusing sounds and visual distractions." <br />29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.