Laserfiche WebLink
5. Discharge to the floor, to an ITindirect waste receptor or to the outdoors. <br />6. Discharge in a manner that does not cause personal injury or structural damage. <br />7. Discharge to a termination point that is readily observable by the building occupants. <br />8. Not be trapped. <br />9. Be installed so as to flow by gravity. <br />10. Terminate not more than 6 inches above and not less than two times the discharge pipe diameter <br />above the floor or flood level rim of the waste receptor. <br />11. Not have a threaded connection at the end of such piping. <br />12. Not have valves or tee fittings. <br />13. Be constructed of those materials listed in Section 605.4 or materials tested, rated and approved <br />for such use in accordance with ASME Al 12.4.1. <br />Section 504.7.9, Pan size and drain, shall be amended to read as follows: <br />Section 504.7.1 Pan size and drain. The pan shall be not less than 11/2 inches (38 mm) in depth and <br />shall be of sufficient size and shape to receive all dripping or condensate from the tank or water heater. <br />The pan shall be drained by an indirect waste pipe having a diameter of not less than 3/4 inch (19 mm). <br />Piping for safety pan drains shall be of those materials listed in Table 605.4. Multi a pan drainsmma; <br />terminate tom_amITsinlemITdischargewaping sw/stem when approved b the administrative authority and <br />permitted by the manufactures installation instructions and installed with those instructions,., <br />Section 604.4, Maximum flow and water consumption, shall be amended by adding Section <br />604.4.9, State maximum flow rate, to read as follows: <br />604.4.1 State maximum flow rate. Where the State mandated maximum flow rate is more restrictive <br />than those of this section, the State flow rate shalltakeprecedence. <br />Se,r #5 in their <br />Section 606.2, Location of shutoff valves, shall be amended to read as follows: <br />606.2 Location of shutoff valves. Shutoff valves shall be installed in the following locations: <br />1. On the fixture supply to each plumbing fixture other than bathtubs and showers in one- and two <br />family residential occupancies, and other than in individual sleeping units that are provided with <br />unit shutoff valves in hotels, motels, boarding houses and similar occupancies. <br />3. On the water supply pipe to each appliance or mechanical equipment. <br />4 Amendments to 2015 IPC <br />