My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2020
>
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2020 12:30:14 PM
Creation date
10/13/2020 12:22:02 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
immediately discernible. The fire department shall not be deterred or <br />hindered from gaining immediate access to fire protection equipment or fire <br />hydrants." <br />Section 509.1, Identification, shall be amended to add Section 509.1.2, Sign <br />Requirements, as follows: <br />"509.1.2 Sign Requirements. Unless more stringent requirements <br />apply, lettering for signs required by this section shall have a minimum height <br />of 2 inches (50.8 mm) when located inside a building and 4 inches (101.6 mm) <br />when located outside, or as approved by the fire code official. The letters shall <br />be of a color that contrasts with the background." <br />In Section 603.3.2.1, Quantity Limits, the Exception shall be amended to read as <br />follows: <br />"Exception: The aggregate capacity limit shall be permitted to be <br />increased to 3,000 gallons (11,356 L) in accordance with all requirements of <br />Chapter 57." <br />Section 603.3.2.2, Restricted use and connection, shall be amended to read as <br />follows: <br />"603.3.2.2 Restricted Use and Connection. Tanks installed in <br />accordance with Section 603.3.2 shall be used only to supply fuel oil to fuel - <br />burning equipment installed in accordance with Section 603.3.2.4. <br />Connections between tanks and equipment supplied by such tanks shall be <br />made using closed piping systems." <br />Section 604, EMERGENCYAND STANDBYPOWER SYSTEMS, shall be amended <br />to read as follows: <br />"604.1 General. Emergency power systems and standby power <br />systems required by this code or the International Building Code shall comply <br />with Sections 604.1.1 through 604.1.8. <br />"604.1.1 Stationary Generators. Stationary emergency and <br />standby power generators required by this code shall be listed in <br />accordance with UL 2200. <br />"604.1.2 Installation. Emergency power systems and standby <br />power systems shall be installed in accordance with the International <br />Building Code, NFPA 70, NFPA 110 and NFPA 111. Existing installations <br />17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.