My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2020
>
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2020 12:30:14 PM
Creation date
10/13/2020 12:22:02 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
be provided in temporary air -supported and air -inflated membrane <br />structures in accordance with section 3103.10.4." <br />There are no changes to Sec. 604.2.14. <br />"604.2.15 Smoke Control Systems. Standby power shall be <br />provided for smoke control systems in the following occupancies, or as <br />specified elsewhere in this code, as required in Section 909.11: <br />Covered Mall Building, International Building Code, Section 402.7 <br />Atriums, International Building Code, Section 404.7 <br />Underground Buildings, International Building Code, Section 405.8 <br />Group I-3, International Building Code, Section 408.4.2 <br />Stages, International Building Code, Section 410.3.7.2 <br />Special Amusement Buildings (as applicable to Group A's), <br />International Building Code, Section 411.1 <br />Smoke Protected Seating, Section 1029.6.2.1 <br />"604.1.16 Underground Buildings. Emergency and standby <br />power shall be provided in underground buildings as required in <br />Section 405 of the International Building Code and shall be in <br />accordance with Section 604. <br />"604.2.17 Covered and Open Mall Buildings. Emergency <br />power shall be provided in accordance with Section 907.2.20 and <br />914.2.3. <br />"604.2.18 Airport Traffic Control Towers. A standby power <br />system shall be provided in airport traffic control towers more than 65 <br />ft. in height. Power shall be provided to the following equipment: <br />"1. Pressurization equipment, mechanical equipment and lighting. <br />"2. Elevator operating equipment. <br />"3. Fire alarm and smoke detection systems. <br />"604.2.19 Smokeproof Enclosures and Stair Pressurization <br />Alternative. Standby power shall be provided for smokeproof <br />enclosures, stair pressurization alternative and associated automatic <br />fire detection systems as required by the International Building Code, <br />Section 909.20.6.2. <br />"604.2.20 Elevator Pressurization. Standby power shall be <br />provided for elevator pressurization system as required by the <br />19 <br />