My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2020
>
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2020 12:30:14 PM
Creation date
10/13/2020 12:22:02 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"[F] Section 903.3.1.2.3 Attics and Attached Garages. Sprinkler <br />protection is required in attic spaces of such buildings two or more stories in <br />height, in accordance with NFPA 13 and or NFPA 13R requirements, and <br />attached garages." <br />Section 903.3.1.3, NFPA 13D sprinkler systems, shall be amended to read as <br />follows: <br />"903.3.1.3 NFPA 13D Sprinkler Systems. Automatic sprinkler <br />systems installed in one- and two-family dwellings; Group R-3; Group R-4 <br />Condition 1 and townhouses shall be permitted to be installed throughout in <br />accordance with NFPA 13D or in accordance with state law." <br />Section 903.3., Installation requirements, shall be amended to add Sec. <br />903.3.1.4, Freeze protection, to read as follows: <br />"903.3.1.4 Freeze protection. Freeze protection systems for <br />automatic fire sprinkler systems shall be in accordance with the requirements <br />of the applicable referenced NFPA standard and this section. <br />"903.3.1.4.1 Attics. Only dry -pipe, preaction, or listed <br />antifreeze automatic fire sprinkler systems shall be allowed to protect <br />attic spaces. <br />`Exception: Wet -pipe fire sprinkler systems shall be allowed to <br />protect non -ventilated attic spaces where: <br />"1. The attic sprinklers are supplied by a separate floor control <br />valve assembly to allow ease of draining the attic system <br />without impairing sprinklers throughout the rest of the <br />building, and <br />"2. Adequate heat shall be provided for freeze protection as per the <br />applicable referenced NFPA standard, and <br />"3. The attic space is a part of the building's thermal, or heat, <br />envelope, such that insulation is provided at the roof deck, <br />rather than at the ceiling level. <br />"903.3.1.4.2 Heat trace/insulation. Heat trace/insulation <br />shall only be allowed where approved by the fire code official for small <br />sections of large diameter water -filled pipe." <br />27 <br />