My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2020
>
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2020 12:30:14 PM
Creation date
10/13/2020 12:22:02 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"905.2 Installation Standard. Standpipe systems shall be installed in <br />accordance with this section and NFPA 14. Manual dry standpipe systems <br />shall be supervised with a minimum of 10 psig and a maximum of 40 psig air <br />pressure with a high/low alarm." <br />Section 905.3, Required Installations, shall be amended to add Section 905.3.9, <br />Buildings exceeding 10,000 sq. ft., and exception to read as follows: <br />"905.3.9 Buildings Exceeding 10,000 sq. ft. In buildings exceeding <br />10,000 square feet in area per story and where any portion of the building's <br />interior area is more than 200 feet (60960 mm) of travel, vertically and <br />horizontally, from the nearest point of fire department vehicle access, Class I <br />automatic wet or manual wet standpipes shall be provided. <br />"Exceptions: <br />"1. Automatic dry and semi-automatic dry standpipes are allowed as <br />provided for in NFPA 14. <br />"2. R-2 occupancies of four stories or less in height having no interior <br />corridors.' <br />Section 905.4, Location of Class 1 standpipe hose connections, shall be amended <br />to read as follows: <br />"905.4 Location of Class I standpipe hose connections. Class I <br />standpipe hose connections shall be provided in all of the following locations: <br />"1. In every required exit stairway, a hose connection shall be provided <br />for each story above and below grade plane. Hose connections shall <br />be located at an intermediate landing between stories, unless <br />otherwise approved by the fire code official. <br />"2. On each side of the wall adjacent to the exit opening of a horizontal <br />exit. <br />"Exception: Where floor areas adjacent to a horizontal exit are <br />reachable from an interior exit stairway hose connection by a 30 - <br />foot (9244 mm) hose stream nozzle attached to 100 feet (30 480 <br />mm) of hose, a hose connection shall not be required at the <br />horizontal exit. <br />"3. In every exit passageway, at the entrance from the exit passageway <br />to other areas of a building. <br />29 <br />