My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2020
>
2020-052 - Amendments to Chapter 12 Article III, "Fire Code," Section 12-53
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2020 12:30:14 PM
Creation date
10/13/2020 12:22:02 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the building. When cumulative building, or fire alarm system, remodel <br />or expansion initiated after the date of original fire alarm panel <br />installation exceeds 50% of the building, or fire alarm system, the fire <br />alarm system must comply within 18 months of permit application. <br />"1103.7.8.1 Communication requirements. Refer to Section 907.6.6 <br />for applicable requirements." <br />Section 2304.1, Supervision of dispensing, shall be amended to read as follows: <br />"2304.1 Supervision of Dispensing. The dispensing of fuel at motor <br />fuel -dispensing facilities shall be in accordance with the following: <br />"1. Conducted by a qualified attendant; and/or, <br />"2. Shall be under the supervision of a qualified attendant; and/or <br />"3. Shall be an unattended self-service facility in accordance with <br />Section 2304.3. <br />"At any time the qualified attendant of item Number 1 or 2 above is not <br />present, such operations shall be considered as an unattended self-service <br />facility and shall also comply with Section 2304.3." <br />Section 2401.2, Non applicability, shall be deleted in its entirety. <br />Table 3206.2, General Fire Protection and Life Safety Requirements, shall be <br />amended to amend footnote j to read as follows: <br />"j. Where storage areas are protected by either early suppression fast <br />response (ESFR) sprinkler systems or control mode special application <br />sprinklers with a response time index of 50 (m • s) 1/2 or less that are <br />listed to control a fire in the stored commodities with 12 or fewer <br />sprinklers, installed in accordance with NFPA 13, manual smoke and <br />heat vents or manually activated engineered mechanical smoke <br />exhaust systems shall be required within these areas." <br />Section 3310.1, Required access, shall be amended to read as follows: <br />"3310.1 Required access. Approved vehicle access for fire fighting <br />shall be provided to all construction or demolition sites. Vehicle access shall <br />be provided to within 100 feet (30 480 mm) of temporary or permanent fire <br />department connections. Vehicle access shall be provided by either temporary <br />M <br />
The URL can be used to link to this page
Your browser does not support the video tag.