My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-051 - Amendments to Section 7-18 of Article II Building Code Chapter 7 - Buildings and Building Regulations - Revise the Local Amendment sot the 2015 International Building Code and the 2015 International Residential Code
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2020
>
2020-051 - Amendments to Section 7-18 of Article II Building Code Chapter 7 - Buildings and Building Regulations - Revise the Local Amendment sot the 2015 International Building Code and the 2015 International Residential Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2020 12:27:37 PM
Creation date
10/13/2020 12:23:55 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. In every exit passageway, at the entrance from the exit passageway to other areas of a building. <br />Exception: Where floor areas adjacent to an exit passageway are reachable from an +eteKiGf exit <br />stairway hose connection by a a 30 -foot (9144 mm) hose stream from a nozzle attached to 100 <br />feet (30 480 mm) of hose, a hose connection shall not be required at the entrance from the exit <br />passageway to other areas of the building. <br />4. In covered mall buildings, adjacent to each exterior public entrance to the mall and adjacent to each <br />entrance from an exit passageway or exit corridor to the mall. In open mall buildings, adjacent to <br />each public entrance to the mall at the perimeter line and adjacent to each entrance from an exit <br />passageway or exit corridor to the mall. <br />5. Where the roof has a slope less than four units vertical in 12 units horizontal (33.3 -percent slope), <br />each standpipe shall bq..provided with a two-way a -hose connection Ghall be located to serve the <br />roof or at the highest landing of an interie exit stairway with stair access to the roof provided in <br />accordance with Section 1011.12. <br />6. Where the most remote portion of a non-sprinklered flor or story is more than 150 feet (45 720 <br />mm) from a hose connection or the most remote portion of a sprinklered floor or story is more than <br />200 feet (60 960 mm) from a hose connection, the fire code official is authorized to require that <br />additional hose connections be provided in approved locations. <br />7. When_re uiq red by this Chapter standpipe connections shall ,bewplaced ad'acenL t to all required exits <br />to the structure and at two hundred feet'2i 00) intervalsµ alon � ma'or corridors thereafter, or as <br />otherwise a roved bv the fire code official. <br />Section 905.9, Valve supervision, shall be amended to add a second paragraph after the Exceptions <br />to read as follows: <br />[F] Sprinkler and standpipes stem water -flow detectors shall_ be orovided for each floor tac to the s rinkler <br />s sty em and shall_cause an alarm upon detection of water flow for more than 45 seconds. All control valves <br />in the sprinkler and standpipe systems ,except for fire de artment µwhose connection valves shall be <br />electncallysupervised to initiate a supITerviso sional at the central IT,station wwuoon tampering. <br />Section 907.1, General, shall be amended to add Section 907.1.4, Design standards, to read as <br />follows: <br />[F] 907.1.4 Desi n standards. Where a new fire alarm s stem is installed the devices shall be <br />addressable.mm Fire alarm systems utilizing,.M a than 20 smoke detectors µshall have analog initiatim <br />devices. <br />Section 907.2.1, Group A, shall be amended to read as follows: <br />[F] 907.2.1 Group A. A manual fire alarm system that activates the occupant notification system in <br />accordance with Section 907.5 shall be installed in Group A occupancies ,.Fe the having an occupant <br />load due to the assembly „,,,,.y ,s of 300 or more mm_µµ �_ <br />_ ar�ersons or more than 100 persons above or below <br />the lowest level of exit discharge. Group A occupancies not separated from one another in accordance <br />with Section 707.3.10 of the International Building Code shall be considered as a single occupancy for the <br />purposes of applying this section. Portions of Group E occupancies occupied for assembly purposes shall <br />be provided with a fire alarm system as required for the Group E occupancy. <br />Exception: Manual fire alarm boxes are not required where the building is equipped throughout <br />with an automatic sprinkler system installed in accordance Section 903.3.1.1 and the occupant <br />notification appliances will activate throughout the notification zones upon sprinkler water flow. <br />Activation of fire alarm notification a pliances shall: <br />1. Cause illumination of the means_of ecress with light of not lessthan1 foot-candle 111 luK pt the <br />walking surface level,, and <br />2. -Sto conflicting or confusing„sounds and visual distractions„. <br />Section 907.2.3, Group E, shall be amended to read as follows: <br />[F] 907.2.3 Group E. A manual fire alarm system that initiates the occupant notification signal utilizing an <br />emergency voice/alarm communication system meeting the requirements of Section 907.5.2.2 and installed <br />in accordance with Section 907.6 shall be installed in Group E educational occupancies. When automatic <br />............. .......... ................. ----.. _.... ................ — - -........ ...................... --- ........ <br />8 2015 IBC <br />Amendments <br />
The URL can be used to link to this page
Your browser does not support the video tag.