1020.1 Construction. <br />Exceptions: <br />6. In e rrouc_Bm_occucancies, corridor walls and ceilings need notbeof fire -resistive construction <br />within a single tenantITsp ge when the s ace is a ui , ed with a roved automatic smoke - <br />detection within the corridor. The actuation of any detector shall activatemmself-annunciating <br />alarms audible in all areas within the corridor. Smoke detectors shall be connected to an <br />aproyedITautomaticwfire alarms stem where such system 1§ ed <br />Section 9029.1.1.1, Spaces under grandstands and bleachers shall be deleted in its entirety. <br />Section 1101.1 Scope, shall be amended by adding the following exception to read as follows: <br />follows: <br />1101.1 Scope: .. . <br />Exception,, CoMppnents of ro�ects regulated by and re istered with Architectural Barriers <br />Division of Texas De garment of Licensin and Re ulation shall be deem,edm to bewwiwncomoliance <br />with the re uirements of this chapter... <br />Section 1203. 1, General, shall be amended to read as follows: <br />1203.1 General. Buildings shall be provided with natural ventilation in accordance with Section 1203.4, <br />or mechanical ventilation in accordance with the International Mechanical Code. <br />Where air infiltration rate in a dwelling unit is less than 5 air changes or less per hour when tested <br />with a blower door at a pressure 0.2 inch w.c. (50 Pa) in accordance with Section 402.4.1.2 of the <br />International Energy Conservation Code, the dwelling unit shall be ventilated by mechanical means in <br />accordance with Section 403 of the International Mechanical Code. <br />Table 1505. 1, Minimum Roof Covering Classification For Types of Construction shall be amended <br />to delete footnote c in its entirety and to replace footnote b to read as follows: <br />b. Non -classified roof coverings shall be permitted on buildings of U occupancies having not more than <br />120 sq. ft. of protected roof area. When exceeding 120 sq. ft. of protected roof area, buildings of U <br />occupancies may use non -rated non-combustible roof coverings. <br />G. [delete] <br />Section 1505.7, Special purpose roofs, shall be deleted in its entirety. <br />Section 1511. 1, General, shall be amended to read as follows, with the text of the Exception to <br />remain unchanged: <br />1511.1 General. Materials and methods of applications used for recovering or replacing an existing roof <br />covering shall comply with the requirements of Chapter 15. All individual replacement shingles or shakes <br />shall be in cornmance with the rating recuired by Table 1505. 1, <br />{Text of the Exceptions remain unchanged.} <br />Section 1704.2, Special inspections and tests, is amended to read as follows: <br />1704.2 Special inspections and tests. Where application is made to the Building Official for construction <br />as specified in Section 105, the owner or the owner's authorized agent_or the registered des_in <br />gofessional in responsible chargee, other than the contractor, shall employ one or more approved <br />agencies to provide special inspections and tests during construction on the types of work listed under <br />Section 1705 and identify the approved agencies to the Building Official. Thespecial inspector shall not <br />13 2015 IBC <br />Amendments <br />