My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-051 - Amendments to Section 7-18 of Article II Building Code Chapter 7 - Buildings and Building Regulations - Revise the Local Amendment sot the 2015 International Building Code and the 2015 International Residential Code
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2020
>
2020-051 - Amendments to Section 7-18 of Article II Building Code Chapter 7 - Buildings and Building Regulations - Revise the Local Amendment sot the 2015 International Building Code and the 2015 International Residential Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2020 12:27:37 PM
Creation date
10/13/2020 12:23:55 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
In other than E wOgq�ancies the minimum number of fixtures in Table 2902.1 ma be lowered if <br />requestedwwi_nw_writin b, thea Iicant statin reasons for a reduced number and a rovedmITb the Building <br />Official. <br />Table 2902. 1, Minimum Number of Required Plumbing Fixtures, shall be amended to add footnote <br />f to read as follows: <br />f. Drinking fountains are not recuired in M Occu ancies with an occupant load of 100 or less, B <br />Occupancies with an occupant_load of or less, and for dining and/or drinking, establishments., <br />Section 2902. 1, Minimum number of fixtures, shall be amended by adding new Sections 2902.1.3, <br />Additional fixtures; 2902.1.3.1, Hand washing lavatory; and 2092.1.3.2, Service sink; to read as <br />follows: <br />2902.1.3 Additional fixtures for food preparation facilities. In addition to the fixtures required in this <br />Chapter, all food service facilities shall be provided with additional fixtures set out in this section. <br />2902.1.3.1 Hand washing lavatory. At least one hand washing lavatory shall be provided for use <br />by employees that is accessible from food preparation, food dispensing and ware washing areas. <br />Additional hand washing lavatories may be required based on convenience of use by employees. <br />2902.1.3.2 Service sink. In new or remodeled food service establishments, at least one service <br />sink or one floor sink shall be provided so that it is conveniently located for the cleaning of mops <br />or similar wet floor cleaning tool and for the disposal of mop water and similar liquid waste. The <br />location of the service sink(s) and/or mop sink(s) shall be approved by the <Jurisdiction's> <br />health department. <br />Section 3002. 1, Hoistway enclosure protection, shall be amended to add the following Exceptions <br />to read as follows: <br />3002.1 Hoistway enclosure protection. . . <br />Exceptions: <br />1. Elevators wholely located within atriums complying with Section 404 shall not require b( is wad <br />enclosure protection. <br />2.W Elevators in o en or enclosed oarkina aaraaes that serve only the Arkin _gfggp�, and com i irn,w <br />with Sections 406.5 and 406.6 resoectively, shall not require hoistway enclosure roo te_ction. <br />Section 3005.4 Machine rooms, control rooms, machinery spaces and control spaces, shall be <br />amended to read as follows: <br />3005.4 Machine rooms, control rooms, machinery spaces and control spaces. Elevator machine <br />rooms control rooms control spaces and machinery spaces shall be enclosed with fire barriers <br />constructed in accordance with Section 707 or horizontal assemblies constructed in accordance <br />with Section 711. or both. The fire -resistance rating shall not be less than the required rating of the <br />hoistway enclosure served by the machinery. Openings in the fire barriers shall be protected with <br />assemblies having a fire protection rating not less than that required for the hoistway enclosure doors. <br />{The Exceptions remain unchanged.} <br />Section 3005, MACHINE ROOMS, shall be amended by adding Section 3005.7, Fire protection in <br />machine rooms, control rooms, machinery spaces and control spaces, to read as follows: <br />3005.7 Fire Protection in machine rooms control rooms machinery spaces and control spaces. <br />3005.7.1 Automatic sprinkler system. The buildirn shall bee ui ped throughout with an <br />autowmaticw_sorinkle_ r system in accordance with Section 903.3.1.1 exce t as otherwwise permitted <br />y 9031.1 and asaprohibited by Section 3005.7.2.1. <br />b _ITSection 903.3.1., <br />15 2015 IBC <br />Amendments <br />
The URL can be used to link to this page
Your browser does not support the video tag.