Exceptions: <br />1. {Existing text unchanged} <br />2. Except as permitted in Sections 308 and 6104.3.3, LP -gas containers are not permitted <br />in residential areas. <br />Please note that current State Law does not allow for the enforcement of any rules more stringent <br />than that adopted by the State, so this amendment is only applicable as to the extent allowed by <br />that State Law. <br />Add Section 6104.3.3, Spas, pool heaters, and other listed devices, to read as follows: <br />6104.3.3 Spas, pool heaters, and other listed devices. Where natural gas service is not available, <br />an LP -gas container is allowed to be used to supply spa and pool heaters or other listed devices. <br />Such container shall not exceed 250 -gallon water capacity per lot. See Table 6104.3 for location of <br />containers. <br />Exception: Lots where LP -gas can be off-loaded wholly on the property where the tank is located <br />may install up to 500 gallon above ground or 1,000 gallon underground approved containers. <br />Amend Section 6107.4, Protecting containers from vehicles, to read as follows: <br />6107.4 Protecting containers from vehicles. Where exposed to vehicular damage due to <br />proximity to alleys, driveways or parking areas, LP -gas containers, regulators and piping shall be <br />protected in accordance with Section 312. <br />Amend Section 6109.13, Protection of containers, by deleting the exception to read as follows: <br />6109.13 Protection of containers. LP -gas containers shall be stored within a suitable <br />enclosure or otherwise protected against tampering. Vehicle impact protection shall be provided <br />as required by Section 6107.4. <br />Amend Ar: &ndixBFire-Flow„ ReauirementsforBuildings as ollows:. <br />Amend Table B105.2, Required Fire Flow for Buildings Other than One- and Two -Family Dwellings, <br />Group R-3 and R-4 Buildings and Townhouses, to amend footnote a. to read as follows: <br />a. The reduced fire -flow shall be not less than 1,500 gallons per minute. <br />(Reason: The minimum fire -flow of 1,500 gpm for other than one- and two- family dwellings has <br />existed since the 2000 edition of the IFC, as well as the Uniform Fire Code before that. Little <br />to no technical justification was provided for the proposed code change at the code hearings. The <br />board believes that the already -allowed 75 percent reduction in required fire -flow for the <br />provision of sprinkler protection is already a significant trade-off. The minimum 1,500 gpm is <br />not believed to be overly stringent for the vast majority of public water works systems in this <br />region, especially since it has existed as the requirement for so many years. Further, the <br />continued progression of trading off more and more requirements in the codes for the provision <br />