Amend Section 503.1, General, to add the following sentence: <br />503.1. General. [Existing text unchanged.] ...Where a building contains more <br />than one distinct type of construction, the building shall comply with the most <br />restrictive area, height, and stories, for the lesser type of construction or be <br />separated by fire walls, except as allowed in Section 510. <br />Amend Table 506.2, ALLOWABLEAREA FACTOR, to delete footnote i. <br />Amend Section 506.3.1, Minimum percentage of perimeter, to add the following <br />sentence: <br />506.3.1 Minimum percentage of perimeter. [Existing text unchanged.] ...In <br />order to be considered as accessible, if not in direct contact with a street or fire <br />lane, a minimum 10 -foot -wide pathway meeting fire department access from the <br />street or approved fire lane shall be provided. <br />Amend Section 708.4.2, Fireblocks and draftstops in combustible construction, <br />Exception 1, to read as follows: <br />708.4.2 Fireblocks and draftstops in combustible construction. [Body of text <br />unchanged.) <br />Exceptions: <br />Buildings equipped with an automatic sprinkler system installed <br />throughout in accordance with Section 903.3.1.1, or in accordance with <br />Section 903.3.1.2 provided that sprinkler protection is provided in the <br />space between the top of the fire partition and the underside of the <br />floor or roof sheathing, deck or slab above as required for systems <br />complying with Section 903.3.1.1. Portions of buildings containing <br />concealed spaces filled with noncombustible insulation as permitted <br />for sprinkler omission shall not apply to this exception for <br />draftstopping. <br />[Remaining Exceptions unchanged.[ <br />Amend Section 718.3, Draftstoppinginn floors, Exception, to read as follows: <br />718.3 Draftstopping in floors. [Body of text unchanged] <br />Exception: Buildings equipped throughout with an automatic sprinkler system in <br />accordance with Section 903.3.1.1. and provided that in combustible construction, <br />sprinkler protection is provided in the floor space. <br />
The URL can be used to link to this page
Your browser does not support the video tag.