Amend Section 903.2.4.2, Group F-1 distilled spirits, to read as follows: <br />903.2.4.2 Group F-1 distilled spirits. An automatic sprinkler system shall be <br />provided throughout a Group F-1 fire area used for the manufacture of distilled <br />spirits involving more than 120 gallons of distilled spirits C>16% alcohol) in the <br />fire area at any one time. <br />Amend Section 903.2.9.3, Group S-1 distilled spirits or wine, to read as follows: <br />903.2.9.3 Group S-1 distilled spirits or wine. An automatic sprinkler system <br />shall be provided throughout a Group S-1 fire area used for the bulk storage of <br />distilled spirits or wine involving more than 120 gallons of distilled spirits or wine <br />C>16% alcohol) in the fire area at any one time. <br />Add Section 903.2.9.5, Self-service storage facility, to read as follows: <br />903.2.9.5 Self -Service Storage Facility. An automatic sprinkler system shall be <br />installed throughout all self-service storage facilities. <br />Exception: Self-service storage facilities with fire area not exceeding 2,500 sq. ft. <br />and not greater than one story above grade plane where all storage spaces are <br />accessed directly from the exterior. <br />Amend Section 903.2.11 and 903.2.11.3 and add 903.2.11.7, 903.2.11.8, and 903.2.11.9 <br />asfollows: <br />903.2.11.3 Buildings 35 feet or more in height. An automatic sprinkler system <br />shall be installed throughout buildings that have one or more stories, other than <br />penthouses in compliance with Section 1510 of the International Building Code. <br />located 35 feet (10668 mm) or more above the lowest level of fire department <br />vehicle access, measured to the finished floor. <br />903.2.11.7 High -Piled Combustible Storage. For any building with a clear <br />height exceeding 12 feet (3587mm), see Chapter 32 to determine if those <br />provisions apply. <br />903.2.11.8 Spray Booths and Rooms. New and existing spray booths and <br />spraying rooms shall be protected by an approved automatic fire -extinguishing <br />system. <br />903.2.11.9 Buildings Over 6.000 sq. ft. An automatic sprinkler system shall <br />be installed throughout all buildings where a fire area with a building area 6,000 <br />sq. ft. or greater and in all existing buildings that are enlarged to be 6,000 sq. ft. or <br />greater without an approved firewall as defined by section 706. <br />11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.