sealed combustion, power -vent, unvented, or electric, the exhaust hood system <br />shall be permitted to exhaust up to 600 cubic feet per minute (0.28 m3 f s) without <br />providing makeup air. Exhaust hood systems capable of exhausting in excess of <br />600 cubic feet per minute (0.28 m3/s) shall be provided with a makeup air at a <br />rate approximately to the difference between the exhaust air rate and 600 cubic <br />feet per minute. <br />Amend Section M2005.2, Prohibited locations, to read as follows <br />M2005.2 Prohibited locations. Fuel -fired water heaters shall not be installed in <br />a room used as a storage closet. Water heaters located in a bedroom or bathroom <br />shall be installed in a sealed enclosure so that combustion air will not be taken <br />from the living space. Access to such enclosure may be from the bedroom or <br />bathroom when through a solid door, weather-stripped in accordance with the <br />exterior door air leakage requirements of the International Energy Conservation <br />Code and equipped with an approved self-closing device. Installation of direct: <br />vent water heaters within an enclosure is not required. <br />Amend Section G2415.2 0404.2,), CSST, to a second paragraph to read as follows: <br />G2415.2 (404.2) CSST. [Text unchanged.] <br />Both ends of each section of medium pressure gas piping shall identify its <br />operating gas pressure with an approved tag. The tags are to be composed of <br />aluminum or stainless steel and the following wording shall be stamped into the <br />tag. <br />"WARNING: 112 to 5 psi gas pressure - Do Not Remove" <br />Amend Section G2415.12 (404.12), Minimum burial depth, to read as follows: <br />G2415.12 (404.12) Minimum burial depth. Underground piping systems shall be <br />installed a minimum depth of 18 inches (457 mm) below grade [remainder of text <br />unchangedl. <br />Delete Section G2415.12.1 (404.12.1), Individual outdoor appliances, in its entirety <br />31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.