of installation and connection, joints, penetrations, and continuity of any element, <br />component, or system in the building <br />Amend Section 802.5.1, Minimum requirement, to read as follows: <br />802.5.1 Minimum requirement. Every portion of open -sided walking surfaces, <br />including mezzanines, equipment platforms, aisles, stairs, ramps, and landings <br />that is more than 30 inches (762 mm) above the floor or grade below and is not <br />provided with guards, or those in which the existing guards are judged to be in <br />danger of collapsing, shall be provided with guards. <br />Amend Section 803.1, Scope, by adding the following sentence: <br />Section 803.1 Scope. [Text unchanged.] ... For the purpose of fire <br />sprinkler protection and fire alarm requirements included in this section, the <br />work area shall be extended to include at least the entire tenant space or spaces <br />bounded by walls capable of resisting the passage of smoke containing the subject <br />work area, and if the work area includes a corridor, hallway, or other exit access, <br />then such corridor, hallway, or other exit access shall be protected in its entirety <br />on that particular floor level. <br />Amend the Exceptions in Section 803.2.6, Supervision, by deleting Exceptions 1-4 and <br />adding the following Exception: <br />Section 803.2.6 Supervision. [Text unchanged.] <br />[Exceptions 1-5 deleted.[ <br />Exception: Supervision is not required where the Fire Code does not require such <br />for new construction. <br />Amend Section 803.3, Standpipes, to read as follows: <br />803.3 Standpipes. Refer to Section 1103.6 of the Fire Code for retroactive <br />standpipe requirements. <br />[Delete rest of Section 803.3.] <br />Amend Section 804.2, General, by deleting Exception 1. <br />42 <br />
The URL can be used to link to this page
Your browser does not support the video tag.