My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13 & 14 Building Code Updates (2)
City-of-Paris
>
City Council
>
Agenda Packets
>
2023
>
04 - APRIL
>
April 10
>
13 & 14 Building Code Updates (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 12:20:03 PM
Creation date
4/6/2023 10:36:35 AM
Metadata
Fields
Template:
AGENDA
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
competence necessary to inspect a particular type of construction requiring <br />special inspection. <br />HIGH-RISE BUILDING. A building with an occupied floor located more than 35 <br />feet (10668 mm) above the lowest level of fire department vehicle access. <br />Amend Section 303.1.3, Associated with Group E occupancies, to add the following <br />sentence: <br />303.1.3 Associated with Group E occupancies. A room or space used for <br />assembly purposes that is associated with a Group E occupancy is not considered <br />a separate occupancy, when applying the assembly requirements of Chapters 10 <br />and 11. <br />Amend Section 304.1, Business Group B, to add the following to the list of occupancies: <br />Fire stations <br />Police stations with detention facilities for 5 or less <br />Amend Section 307.1.1, Cleaning establishments, to add the following sentence to <br />Exception 4: <br />307.1.1 Cleaning establishments. [Text unchanged.] <br />Exceptions: <br />[Text of Exceptions 1-3 unchanged.[ <br />4. Cleaning establishments... [Text unchanged]... See also IFC Chapter 21, Dry <br />Cleaning Plant provisions. <br />Amend Section 403.1, Applicability, Exception 3, to read as follows: <br />403.1 Applicability. [Text unchanged. <br />Exceptions: <br />[Exceptions 1 and 2 unchanged.] <br />3. The open-air portion of a building [remainder unchanged] ... <br />Amend Section 403.3, Automatic Sprinkler System, to delete the exception: <br />Amend Section 403.3.2, Watersupply to requiredflre pumps, to read as follows: <br />[F] 403.3.2 Water supply to required fire pumps. In buildings that are more <br />than 120 feet (36.5 m) in building height, required fire pumps shall be supplied <br />by connections to no fewer than two water mains located in different streets. <br />Separate supply piping shall be provided between each connection to the water <br />
The URL can be used to link to this page
Your browser does not support the video tag.