Laserfiche WebLink
.. .. „.�� i�„ „. �::u,i... ,., ,pm �w, •„. t iry .� m. •” .III.` i::,m �. ,.,I, �. .�� ., a„u ;ym, �lilYrr �il',w �Nde” <br />�u":::��,i,� ��:���.:w���.� ���:.�..,�n���".,,���.m� w������.�� �:���u��:���., ��:°�u��°;�,,:...m. �. ����� �:��Ir..:.:�.�p� �.u�����m.� I.... .. <br />7. ., ) <br />Add Section 604.3.2 and 604.3.2.1: <br />604.3.2 Failure to correct electrical hazards; service disconnection. <br />Where an electrical system hazard identified under Section 604.3 or 604.3.1 is not repaired, <br />corrected, or otherwise mitigated within the time period specified by the code official, or <br />where such condition poses an immediate threat to life, safety, or property, the code <br />official is authorized to order the disconnection of electrical service to the structure until <br />such hazard has been corrected and approved. <br />Conditions warranting disconnection may include, but are not limited to: <br />1. Exposed, damaged, or deteriorated wiring creating shock or fire hazards; <br />2. Electrical systems or equipment damaged by water exposure and not properly repaired <br />or replaced; <br />3. Improper or unsafe electrical installations; <br />4. Overloaded circuits or inadequate service creating fire risk; <br />5. Tampering with electrical equipment, meters, or service; <br />6. Any condition determined by the code official to present an imminent danger to <br />occupants or the structure. <br />Disconnection of electrical service shall be coordinated with the serving utility provider. <br />Restoration of service shall not occur until the hazardous condition has been corrected, <br />inspected, and approved by the code official and, where applicable, the utility provider. <br />604.3.2.1 Emergency disconnection authority: <br />Where an imminent hazard exists, the code official may order immediate disconnection <br />without prior notice. <br />;m <br />(Reason: <br />"m w;m ., .,,,i .„,'^s /ft properq, y, enf6rcerypent <br />o .wl,,, 'W VJwi5cIC Wnie"t,l. immlecl.i,'td <br />si,:,rvice, vd�er ;w ul1W conditions e,xi. t or am m 4 f ° rrec P,I J. inclucfing those, r+ wl inti g <br />Amend Section 605.2 to read as follows: <br />605.2 Receptacles. <br />Every habitable space in a dwelling shall contain not less than two separate and remote <br />receptacle outlets. E <br />Feeeptaele 9F a Fereeptaele with a gFOUna fa .i+ U*+ inteFFUpteF. Every bathroom shall <br />contain not less than one receptacle. Any new bathroom receptacle outlet shall have <br />