Amend Section 306.5.1; change to read as follows: <br />306.5.1 Sloped Roofs. Where appliances, equipment, fans or other components that require <br />service are installed on a roof having a slope of 3 units vertical in 12 units horizontal (25 - <br />percent slope) or greater and having an edge more than 30 inches (762 mm) above grade <br />at such edge, a catwalk at least 16 inches in width with substantial cleats s Paced not more <br />than 16 inches a artshall be provided from the roof access to a level platform at the <br />appliance. The level platform shall be provided on each side of the appliance or equipment <br />to which access is required for service, repair or maintenance. The platform shall be not <br />less than 30 inches (762 mm) in any dimension and shall be provided with guards. The <br />guards shall extend not less than 42 inches (1067 mm) above the platform, shall be <br />constructed so as to prevent the passage of a 21 -inch -diameter (533 mm) sphere and shall <br />comply with the loading requirements for guards specified in the International Building <br />Code ... {remainder of text unchanged). <br />(u'e�,,i's��')n: .I c:issure m�i'�i�i�6�i��.;,'�� OCC. "55 ft.; raof pplia,lces. (...Icmsist'nt vvith1FGC,o <br />Amend Section 501.3; add an exception to read as follows: <br />501.3 Exhaust Discharge. The air removed by every mechanical exhaust system shall be <br />discharged outdoors at a point where it will not cause a public nuisance and not less than <br />the distances specified in Section 501.3.1. The air shall be discharged to a location from <br />which it cannot again be readily drawn in by a ventilating system. Air shall not be <br />exhausted into an attic, crawl space, or be directed onto walkways. <br />Exceptions: <br />1. Whole -house ventilation -type attic fans shall be permitted to discharge into the attic <br />space of dwelling units having private attics. <br />2. Commercial cooking recirculating systems. <br />3. Where installed in accordance with the manufacturer's instructions and where <br />mechanical or natural ventilation is otherwise provided in accordance with Chapter 4, <br />listed and labeled domestic ductless range hoods shall not be required to discharge <br />to the outdoors. <br />4. Toilet room exhaust ducts mav terminate in a warehouse_p.[__Lhop area when <br />infiltration of outside air isp1e, sent.„ <br />(' ii.. „ , „; %� i�,pnr. „. ., „.'.,r w^i ...u, . .^ �i.:,m a s�,ilheire . a large v4�.�)Iume tlot (.x,Jltsidde ili,vr is <br />