<br />SECTION 2 <br /> <br />CONTROL STATIONS <br /> <br />Six UHF control stations ~Jith omni directional antenna systems <br />shall be furnished. Three stations shall be local control, two <br />stations shall be DC remote control and one station shall be <br />tone remote control. <br /> <br />'l'he tone remote control station will be installed at the PAris <br />Police Dept. and interfaced to a ComCenter Console. A highly <br />reliable (mininum 100 m.p.h. wind survival) 5 dB gain omni <br />directional Lase station antenna, side mount, and 45 feet of <br />LDF4-S0 heliax cable , connectors and jumper kit is required. <br /> <br />A DC remote control station shall be installed.in the Emergency <br />Operations Center at the City Hall and interfaced to existing <br />reIaote controls. A 5 db antenna as above with sufficent LDF4-S0 <br />Heliax cable, connectors and mounting hardware to mount at the <br />35 ft. level on the tower on the roof of City Hall are required. <br /> <br />A DC re~ote centrol station shall be installed at the Water Treatment <br />Plant at Lake Crook and interfaced with existing rrnnote control. <br />This station will also have 12 volt DC battery Lackup capability. <br />A 5db omni antenna as aLove with sufficcnt 1df4-50 Heliax cable <br />and connectors shall Le installed on the roof of the building. <br /> <br />A local control station shalf Le' installed at Public Work~ Offices <br />on I.. Hickory ~trcet and interfaced with exis ting local control <br />desk set and :nicrophone speaker combinations. A SdD omni antenna <br />\1;i th sufficcnt LD1'4-50 ltcliux cuble emu connccto:a.., shall Le roof mounteu <br />near present VIlF antenna. <br /> <br />l~ locnl control station shall Lc installed at the Hastewater Treatment <br />Plant on US I!v,ly 271 North of Paris. A 5 ub oInni antenna \d th sufficent <br />LDF4-S0 Iieliax Cable and connectors will be installed above roof <br />level. <br /> <br />A local control station shall be installed at the City of Paris <br />An~aal Shelter on CleDent Rd. a 3 db omni direction antenna <br />with RGO/U coaxial cable and connectors shall be installed above <br />roof level. <br /> <br />The radio sets shall be a compact, reliable state of the art <br />technically advanced UHF FM two way radio. Units must be vlideband, <br />synthesized, PC programmable, rugged, minimum two channel capability <br />for repeater & talkaround operation, prograw~able tone & digital <br />coded squelch, microprocessor controlled for RF and coded squelch <br />frequencies. 'l'he stations will be fully operational for local <br />control as well as rer:\ote control \-,here specified. Stations shall <br />havc;Phogran~able carrier control timer to prevent system tie-ups. <br /> <br />. ... J ' <br />