<br />HAYTER
<br />ENGINEERING, INC.
<br />
<br />4445 S.E. LOOP 286
<br />PARIS, TEXAS 75460
<br />(903) 785-0303
<br />~AX (903) 785-0308
<br />
<br />CONSULTANTS PLANNERS ENGINEERS
<br />
<br />ATTACHMENT TO CHANGE ORDER ONE
<br />
<br />
<br />
<br />1. Select fill under the c1arifier--$7,500.00
<br />2. Oil coolers for the spray field pumps--$3,338.00
<br />3. Level sensors for the sludge holding tanks--$3,360.00
<br />4. Ball check valves in the wetwells--$3,6I2.I5
<br />5. Plug valve in 4" line to the ATAD building--$2,106.80
<br />6. Pre-ATAD holding tank level indicator--$1,229.35
<br />7. Larger conduit at the wetwells--$443.38
<br />8. Thermal overloads for the 6 Flygt pumps for $517.50
<br />9. Networking cable for the two AT AD controllers--$990.00
<br />
<br />,',
<br />"
<br />~ . ' Ii .
<br />Ul r ,r
<br />itl 010
<br />IIIJ~.....,.", //1
<br />1',-' I
<br />',ii " ' ~\:,
<br />Ii' ,', Ft."
<br />I . ' ...........E'-t '-t
<br />I.' ,.~.'..~ fill zt:..A, ...;f~ '.
<br />:1:" f: ~ \.*~
<br />i. ::.'. ' Mic'HAEl'N:'!riBBtfs~
<br />::' fi'''-65484:~7iJ
<br />i," fA "'~"~f" ~t.l" I ~~a 1f
<br />.,~~.~lst(o';~"~~'f
<br />;' '~:IOHACt.!4f'P
<br />;. \\'1ll,ttk."IIo."tt="'"
<br />i. :
<br />
<br />i:: l
<br />1;,11
<br />i'I.:'
<br />""\'
<br />
<br />CHANGE ORDER TOTAL
<br />
<br />$23,097.18
<br />
<br />ORIGINAL CONTRACT AMOUNT
<br />
<br />$3,798,000.00
<br />
<br />NEW CONTRACT AMOUNT
<br />
<br />$3,821,097.18
<br />
<br />i
<br />! ~
<br />
<br />" ,
<br />i I ;
<br />!'IM
<br />. l~ ,. ~ J i
<br />';:1\'\,'
<br />Ii'"
<br />I':'
<br />; ;':(;'
<br />
<br />'1,1 II
<br />;(i
<br />
<br />, i::
<br />
<br />An increase in contract time of 155 days will take the original contract completion date of
<br />November 26, 1997 to May 1, 1998. This is justified by the unusual weather experienced by the
<br />contractor that hampered construction during this time period, the time required to install the
<br />above change order items, and delays brought on by the necessity of working with the staff of the
<br />plant to keep operations on-going during construction (e.g.- testing the new spray field pumps
<br />could not begin until the sludge disposal site was dry enough to dispose of sludge, the clarifiers
<br />could not be taken out of service until the flow equalization facility had reached an acceptable
<br />level, excavation for the new clarifier could not begin until TV Electric moved their poles and
<br />lines, etc.).
<br />
<br />! ,':+
<br />,"I'.
<br />
<br />;;:C,i
<br />I'; ,
<br />I;" ]
<br />l; :~ i
<br />:L" .Ii
<br />: I
<br />, '
<br />. . >
<br />,(:\
<br />; ~ , I !1'
<br />.',,:/1
<br />Ii'"
<br />,:
<br />II:
<br />'J
<br />i :.~ I
<br />"
<br />il :;:
<br />, I'
<br />I; I,
<br />,!,
<br />
<br />
<br />ORIGINAL CONTRACT COMPLETION DATE November 26,1997
<br />
<br />CHANGE ORDER TIME INCREASE
<br />
<br />155 Days
<br />
<br />i
<br />~ ;
<br />i /;
<br />\ ",(\'"
<br />1:li
<br />, q 1
<br />I'll
<br />il"
<br />,:r.
<br />I,. ,
<br />.I"i
<br />,\\;
<br />i,I,:,
<br />/',1
<br />t\:,
<br />:',
<br />
<br />NEW CONTRACT COMPLETION DATE