Laserfiche WebLink
<br />',. <br /> <br />. , . <br />: ~.1 ' I : <br />:i I' <br /> <br />jilii:, <br />; '~I~. rl',. <br />!I".t <br />!.~~ . <br />" <br />~ I' <br />:,.!; <br />~' I ; i :;: <br />:lJ; <br />",.j, <br />P';\; <br />: ;:1 ~ \ <br />1::!1 <br />I: 'I' <br />.1-:. ,. <br />;:1:'1 <br />":\1:1' <br />.j'il <br />j:) .; <br />'tl!:, <br />.,,1 <br /> <br /> <br />HAYTER <br />ENGINEERING, INC. <br /> <br />4445 S.E. LOOP 286 <br />PARIS, TEXAS 75460 <br />(903) 785-0303 <br />~AX (903) 785-0308 <br /> <br />CONSULTANTS PLANNERS ENGINEERS <br /> <br />ATTACHMENT TO CHANGE ORDER ONE <br /> <br /> <br /> <br />1. Select fill under the c1arifier--$7,500.00 <br />2. Oil coolers for the spray field pumps--$3,338.00 <br />3. Level sensors for the sludge holding tanks--$3,360.00 <br />4. Ball check valves in the wetwells--$3,6I2.I5 <br />5. Plug valve in 4" line to the ATAD building--$2,106.80 <br />6. Pre-ATAD holding tank level indicator--$1,229.35 <br />7. Larger conduit at the wetwells--$443.38 <br />8. Thermal overloads for the 6 Flygt pumps for $517.50 <br />9. Networking cable for the two AT AD controllers--$990.00 <br /> <br />,', <br />" <br />~ . ' Ii . <br />Ul r ,r <br />itl 010 <br />IIIJ~.....,.", //1 <br />1',-' I <br />',ii " ' ~\:, <br />Ii' ,', Ft." <br />I . ' ...........E'-t '-t <br />I.' ,.~.'..~ fill zt:..A, ...;f~ '. <br />:1:" f: ~ \.*~ <br />i. ::.'. ' Mic'HAEl'N:'!riBBtfs~ <br />::' fi'''-65484:~7iJ <br />i," fA "'~"~f" ~t.l" I ~~a 1f <br />.,~~.~lst(o';~"~~'f <br />;' '~:IOHACt.!4f'P <br />;. \\'1ll,ttk."IIo."tt="'" <br />i. : <br /> <br />i:: l <br />1;,11 <br />i'I.:' <br />""\' <br /> <br />CHANGE ORDER TOTAL <br /> <br />$23,097.18 <br /> <br />ORIGINAL CONTRACT AMOUNT <br /> <br />$3,798,000.00 <br /> <br />NEW CONTRACT AMOUNT <br /> <br />$3,821,097.18 <br /> <br />i <br />! ~ <br /> <br />" , <br />i I ; <br />!'IM <br />. l~ ,. ~ J i <br />';:1\'\,' <br />Ii'" <br />I':' <br />; ;':(;' <br /> <br />'1,1 II <br />;(i <br /> <br />, i:: <br /> <br />An increase in contract time of 155 days will take the original contract completion date of <br />November 26, 1997 to May 1, 1998. This is justified by the unusual weather experienced by the <br />contractor that hampered construction during this time period, the time required to install the <br />above change order items, and delays brought on by the necessity of working with the staff of the <br />plant to keep operations on-going during construction (e.g.- testing the new spray field pumps <br />could not begin until the sludge disposal site was dry enough to dispose of sludge, the clarifiers <br />could not be taken out of service until the flow equalization facility had reached an acceptable <br />level, excavation for the new clarifier could not begin until TV Electric moved their poles and <br />lines, etc.). <br /> <br />! ,':+ <br />,"I'. <br /> <br />;;:C,i <br />I'; , <br />I;" ] <br />l; :~ i <br />:L" .Ii <br />: I <br />, ' <br />. . > <br />,(:\ <br />; ~ , I !1' <br />.',,:/1 <br />Ii'" <br />,: <br />II: <br />'J <br />i :.~ I <br />" <br />il :;: <br />, I' <br />I; I, <br />,!, <br /> <br /> <br />ORIGINAL CONTRACT COMPLETION DATE November 26,1997 <br /> <br />CHANGE ORDER TIME INCREASE <br /> <br />155 Days <br /> <br />i <br />~ ; <br />i /; <br />\ ",(\'" <br />1:li <br />, q 1 <br />I'll <br />il" <br />,:r. <br />I,. , <br />.I"i <br />,\\; <br />i,I,:, <br />/',1 <br />t\:, <br />:', <br /> <br />NEW CONTRACT COMPLETION DATE <br /> <br />May 1, 1998 <br />