My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
09 Casa Bonita Apartments
City-of-Paris
>
City Council
>
Agenda Packets
>
2001-2010
>
2008
>
02 February
>
2008 02-11
>
09 Casa Bonita Apartments
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2012 1:42:29 PM
Creation date
2/8/2008 4:38:59 PM
Metadata
Fields
Template:
AGENDA
Item Number
09
AGENDA - Type
MISCELLANEOUS
Description
Discussion of Casa Bonita Apts. & funding options for demolition.
AGENDA - Date
2/11/2008
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLM REPORT SUMMARY <br />~ Catas Laboratorias <br />~ 613 S. Bois D'Arc <br />Fomey, Texas 75126 (972) 5644723 <br />I Client: <br />Brady Environmental Services, Inc. <br />P%Iect: <br />City of Paris; Old Casa Bonita Apartments <br />Project No: <br />6239 LS01 <br />Identification: <br />Asbestos, Bulk Sample Analysis <br />Test Method: <br />Polarized Light Microscopy/Dispersion Staining (PLM/DS) <br />EPA Method 600/R-93/116 <br />NVLAP Lab No. 200569-0 <br />TDH Licenso No. 30-0287 <br />Lab Job No.: PLM-01256 <br />Report Date: 6/19/2006 <br />Sample Date: 6/13/2006 <br />Page 1 of 3 <br />On 6/15/2006, eighteen (18) bulk samples were submitte~ by Mr. David Gable of Brady Environmenta! Services, Inc. for asbestos analysis by PLM/DS. <br />Copies of the lab data sheets are atiached: additional information may be found therein. '~'}~e resulu are summarized below: <br />Lab <br />Sample No. <br />Client Sample Description/Location <br />Field I.D. <br />Asbestos Content <br />CL058727 <br />A 1 White 12" X 12" Floor Tile wBlack Mastic - Throughout BuildinB A <br />Detected - Tan Mastic <br />hrysotile - Floor Tile <br />CL058728 <br />A 2 White 12" X 12" Floor Tile wBlack Mastic - Throughout Buildin A <br />B <br />tile - Black Mastic <br />fnehrysoDetect <br />ed - Tan Mastic <br />CL058729 <br />A3 White 12" X 12" Floor Tile wBlack Mastic - Throughout Buildin A <br />8 <br />rysotile - Floor Tile <br />rysotile - Black Mastic <br />None Detected - Tan Mastic <br />CL058730 <br />L058731 <br />L058732 <br />CL058733 <br />CL058734 <br />CL058735 <br />CL058736 <br />CL058737 <br />CL058738 <br />CL058739 <br />CL058740 <br />B 1 Sheetrock / Joint Compound - Throughout Building A <br />2 Sheetrock / Joint Compound - Throughout Building A <br />3 Sheetrock / Joint Compound - Throughout Building A <br />C1 Wall Textuce - Throughout Building A <br />C2 Wall Texture - Throughout Building A <br />C3 Wall Texture - Throughout Building A <br />D1 Black Wall Insulation - Throughout Building A <br />D2 Black Wall Insulation - Throughout Building A <br />D3 Black Wall Insulation - Throughout Building A <br />El Grey Ceiling Insulation - 1'hroughout Building A <br />E2 Grey Ceiling Insulafion - Throughout Building A <br />3% Chrysodle - Floor Tile <br />5% Chrysotile - Black Mastic <br />o <br />2 /o Chrysotile - Joint Compound <br />None Detected - Paper <br />None Detected - Wallboard Material <br />o <br />2 /o Chrysodle - Joint Compound <br />None Detected - Paper <br />None Detected . Wallboard Material <br />2% Chrysotile - Joint Compound <br />None Detected - Paper <br />None Detected - Wa(Iboard Material <br />2% Chrysotile <br />o <br />2 /o ChrysoNle <br />, <br />2 /o Chrysotile <br />None Detected <br />None Detected <br />Nooe Detected <br />None Detected <br />None Detected <br />CL058741 <br />E3 Grey Ceiling Insularion - Throughout Building A <br />None Detected <br />7hese samples were analyzed by layers. The overall percent asbestos for the semple is reported when rolevant. The EPA considers a material W be aslxstos containing <br />only if it corrcains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing <br />Materials (RACM) - materials that are friable or may become friable - be further analyzed by point counting when t}x nsults indicate less thsn ten percent asbestos by <br />CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not ye reprpduced <br />except in full. <br />__T <br />
The URL can be used to link to this page
Your browser does not support the video tag.