19 Public Safety Adoption of 2006 IFC
City-of-Paris
>
City Council
>
Agenda Packets
>
2001-2010
>
2009
>
05 May
>
05-11-2009
>
19 Public Safety Adoption of 2006 IFC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2012 8:24:24 AM
Creation date
5/8/2009 5:30:07 PM
Metadata
Fields
Template:
AGENDA
Item Number
19
AGENDA - Type
MISCELLANEOUS
Description
1994 Standard Fire Code
AGENDA - Date
5/11/2009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(50) Section 903.1.2 shall be added to read as follows: <br />903.1.2 Residential systems. The installation of NFPA 13R <br />sprinkler systems is prohibited. Where such reference is found <br />in this code, NFPA 13 sprinkler system materials, design and <br />installation shall be installed instead on NFPA 13R. Sprinkler <br />coverage of voids between floors as required by NFPA 13 may <br />be omitted when replacing a NFPA 13R system. <br />(51) Section 903.2 shall be amended to delete the exception. <br />(52) Section 903.2.8.3 shall be added to read as follows: <br />Section 903.2.8.3 Self-service storage facility. An automatic <br />sprinkler system shall be installed throughout all self-service <br />storage facilities. <br />Exception: One-story self-service storage facilities that <br />have no interior corridors, with a one-hour fire barrier <br />separation wall installed between every storage compartment. <br />(53) Sections 903.2.10.3, 903.2.10.4, 903.2.10.5, 903.2.10.6 and <br />903.2.10.7 shall be amended to read as follows: <br />903.2.10.3 Buildings more than 35 feet in height. An <br />automatic sprinkler system shall be installed throughout <br />buildings with a floor level, other than penthouses in <br />compliance with Section 1509 of the International Building <br />Code, that is located 35 feet (10 668mm) or more above the <br />lowest level of fire department vehicle access. <br />Exception: <br />Open parking structures in compliance with Section 406.3 of <br />the International Building Code. <br />903.2.10.4 High-Piled Combustible Storage. For any building <br />with a clear height exceeding 12 feet (4572 mm), see Chapter <br />23 to determine if those provisions apply. <br />903.2.10.5 Spray Booths and Rooms. Spray booths and <br />spraying rooms installed, constructed, or remodeled after the <br />adoption of this code shall be protected by an approved <br />automatic fire-extinguishing system. <br />21 <br />~ 000185 <br />