My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13 Public Safety
City-of-Paris
>
City Council
>
Agenda Packets
>
2001-2010
>
2009
>
05 May
>
05-26-2009
>
13 Public Safety
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2012 8:29:00 AM
Creation date
5/21/2009 3:47:17 PM
Metadata
Fields
Template:
AGENDA
Item Number
13
AGENDA - Type
MISCELLANEOUS
Description
2006 Itn'l Building Codes
AGENDA - Date
5/26/2009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. Standpipe system tests where water will be flowed <br />external to the building shall not be conducted during <br />freezing conditions or during the day prior to expected <br />night time freezing conditions. <br />9. Contact the Fire Code Official for requests to remove <br />existing fire hose from Class II and III standpipe systems <br />where employees are not trained in the utilization of this <br />firefighting equipment. All standpipe hose valves must <br />remain in place and be provided with an approved cap and <br />chain when approval is given to remove hose by the Fire <br />Code Official. <br />Section 901.7, Systems out of service, shall be amended to replace the <br />first paragraph as follows: <br />Where a required fire protection system is out of service <br />or in the event of an excessive number of activations, the fire <br />department and the Fire Code Official shall be notified <br />immediately and, where required by the Fire Code Official, the <br />building shall either be evacuated or an approved fire watch <br />shall be provided for all occupants left unprotected by the shut <br />down until the fire protection system has been returned to <br />service. <br />Section 902.1, Definitions, shall be amended to add a sentence to the <br />definition of "Manual dry" under the "STANDPIPES, TYPES OF" <br />definition to read as follows: <br />The system must be supervised as specified in Section 905.2. <br />Section 903.1.2, Residential systems, shall be added to read as follows: <br />The installation of NFPA 13R sprinkler systems is <br />prohibited. Where such reference is found in this code, NFPA 13 <br />sprinkler system materials, design and installation shall be <br />installed instead on NFPA 13R. Sprinkler coverage of voids <br />between floors as required by NFPA 13 may be omitted when <br />replacing a NFPA 13R system. <br />Section 903.2, Where required, shall be amended to delete the <br />exception. <br />Section 903.2.8.3, Self-service storage facility, shall be added to read as <br />follows: <br />20 <br />~ C?C)G0) 7~; <br />