My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13 Public Safety
City-of-Paris
>
City Council
>
Agenda Packets
>
2001-2010
>
2009
>
05 May
>
05-26-2009
>
13 Public Safety
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2012 8:29:00 AM
Creation date
5/21/2009 3:47:17 PM
Metadata
Fields
Template:
AGENDA
Item Number
13
AGENDA - Type
MISCELLANEOUS
Description
2006 Itn'l Building Codes
AGENDA - Date
5/26/2009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
central station upon tampering. <br />Section 906.1, Where required, shall be amended to read as follows: <br />Portable fire extinguishers shall be installed in the following <br />locations: <br />1. In Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. <br />2. Within 30 feet (9,144 mm) of commercial cooking <br />equipment. <br />3. In areas where flammable or combustible liquids are <br />stored, used or dispensed. <br />4. On each floor of structures under construction, except <br />Group R-3 occupancies, in accordance with Section 1415.1. <br />5. Where required by the sections indicated in Table 906.1. <br />6. Special-hazard areas, including but not limited to <br />laboratories, computer rooms, and generator rooms where <br />required by the Fire Code Official. <br />Section 907.1.3, Design Standards, shall be added to read as follows: <br />All alarm systems, new or replacement, serving 20 or more <br />alarm actuating devices shall be addressable fire detection <br />systems. Alarm systems serving more than 40 smoke detectors <br />or more than 100 total alarm activating devices shall be analog <br />intelligent addressable fire detection systems. <br />Exception: Existing systems need not comply unless the <br />total building remodel or expansion initiated after the <br />effective date of this code, as adopted, exceeds 30% of the <br />building. When cumulative building remodel or expansion <br />exceeds 50% of the building must comply within 18 <br />months of permit application. <br />Section 907.2.1, Group A, shall be amended to read as follows: <br />A manual fire alarm system shall be installed in Group A <br />occupancies having an occupant load of 300 or more persons or <br />more than 100 persons above or below the lowest level of exit <br />discharge. Portions of Group E occupancies occupied for <br />25 <br />- i>000'7 7, <br />
The URL can be used to link to this page
Your browser does not support the video tag.