Laserfiche WebLink
<br /> <br /> <br /> Fungal-Biological Hazard Remediation Protocol Irerracon <br /> Grand Theater ® 21 Lamar Street, Paris, Texas <br /> April 11, 2011 ■ Terracon Project No. 94117645 <br /> <br /> 7.0 VENTILATION <br /> <br /> a) The first floor lobby remediation work area will be ventilated with the previously <br /> established ventilation system as defined for the ACM-LBP abatement as referenced <br /> in Scope of Work for Hazardous Materials Abatement, Terracon Project No. <br /> 94107645. Containment/critical barriers must remain in place until interim written <br /> notification of post remediation clearance has been received from the MAC. <br /> <br /> b) The second floor containment must be maintained at a negative pressure differential <br /> of 5 Pascal, or, 0.02 inches of water, with HEPA filtered negative air machines <br /> (NAMS) that are exhausted to the immediate outdoor environment. The containment <br /> should have a minimum of four (4) air changes per hour and shall be operated <br /> continuously for the duration of the project. The negative pressure differential will be <br /> <br /> continuously monitored with a manometer. The containment/critical barriers must <br /> remain in place until interim written notification of post remediation clearance has <br /> been received from the MAC. <br /> <br /> 8.0 PPE DURING FUNGAL REMEDIATION <br /> <br /> a) Workers will wear personal protective equipment consisting of, at a minimum, half <br /> face dual cartridge air purifying respirators with HEPA cartridges (N-100) and full <br /> body disposable coveralls while performing remedial work in the first floor lobby. <br /> <br /> b) Workers will wear PAPR in the second floor containment. <br /> <br /> It is the Contractor's responsibility to ensure that his employees are afforded the respiratory <br /> protection as required by the OSHA standard for respiratory protection (29 CFR 1910.134, <br /> December, 2008) or the respiratory protection requested by the employee. The Contractor <br /> shall ensure the workers are instructed and trained in the proper use, maintenance, and <br /> <br /> care of respiratory protection in accordance with Title 29 CFR 1910.134. Safety glasses, <br /> disposable coveralls, and work gloves must be worn while working in the contained areas. It <br /> is the contractor's responsibility to ensure that workers on scaffold platforms or working from <br /> ladders or other elevated platforms should be safe and secure from slipping or falling. <br /> <br /> 9.0 CLEANING/DECONTAMINATION <br /> <br /> Option 1-Mechanical Cleaning of Non-Porous and Semi-Porous Substrates <br /> <br /> Mechanical cleaning and decontamination procedures shall use HEPA vacuuming and wet <br /> wiping. Wet wiping should be performed with water amended with a non-ionic detergent. <br /> An appropriately labeled and EPA registered biocide may be used on non-porous or semi- <br /> porous substrates. A wire brush or other abrasive techniques will be required to clean non- <br /> <br /> <br /> 4 <br /> F' ..;SaCtrt >t r ~ ®E?rfs+:~tt'i-ertti ■ I ~c'It's~i:6 <br /> . c ~ <br /> [t1 C P 0 07/1 -10-12 <br /> - ,151 <br />