Laserfiche WebLink
Scope of Work - Asbestos Abatement <br />Grand Theatre o 21 Lamar Avenue, Paris, I exas <br />April 14, 2011 e Terracon Project No. 94107645 <br />Irerracon <br />The CONTRACTOR shall mainfain a(I records required by TDSHS Texas Asbesias <br />Healrh Proteciion Rules Section 295.62 Operations: Recordkeeping <br />COPVTRACTOR parking and disposal dumpsfier areas will be as designafed by the <br />OWNER. The CONTRACTOR will keep work and parking areas clean. <br />Prior to any asbestos abatement activities the CONTRACTOR wifl provide a licensed <br />electrician to provide power lock-out and tag-out of all circuits to be affected by the <br />asbestos abatement activities. Lock-out/Tag-out musi meet OSHA 1910.147 <br />requirements. All electrical circuits in the regulated and/or contained area shafl have <br />ground-fault interrupter (GFCI) units installed. <br />Exhaust negative pressure ventilation system to outside of building. <br />The CONTRACTOR shall be responsible for installing hard barriers in any window <br />openings utilized for exhaust of negative pressure and shall ensure that the building can <br />be secured between work periods. If necessary, a hard barrier decontamination unit <br />shall be constructed at the site to ensure buiâ–ºding security. <br />The CONTRACTOR shall arrange the use of on-site toilet facilities with the OWNER or <br />provide temporary self-contained toilet units for use by CONTRACTOR'S personnel <br />throughout the duration of abatement activities. <br />The CONTRACTOR shali install one fire extinguisher in the work area for each 1,000 <br />square feet of work area or fraction thereof. Additional fire extinguishers shall be <br />installed in the Equipment Room and Clean Room of the decontamination unit. <br />The CONTRACTOR shall conduct a safety meeting for CONTRACTOR'S employees <br />with emphasis on operation of fire extinguishers and emergency exits in case of fire. <br />CONTRACTOR shall have posted emergency phone numbers for the fire department <br />and police. <br />CONTRACTOR shall store a minimum of volatile substances on the job site and in fire <br />resistant containers only. <br />6.0 PRODUCTS <br />Amended Water: Provide water to which a surfactant has been added. Use a mixture of <br />surfactant and water which results in wetting of the ACM and retardation of fiber release <br />during disturbance of the material. ~ <br />Disposal Baqs: Provide as a minimurn, individual, G mil ihick, leal<-fight, 7ured <br />pol~~ethylene bags. I J I_I <br />