My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
25-REHABILITATION OF THE EAST ELEVATED STORAGE TANK
City-of-Paris
>
City Council
>
Agenda Packets
>
2011-2020
>
2012
>
05 May
>
05.14.12
>
25-REHABILITATION OF THE EAST ELEVATED STORAGE TANK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2012 3:29:04 PM
Creation date
5/11/2012 6:34:32 PM
Metadata
Fields
Template:
CITY CLERK
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
holidays with a low voltage wet sponge detector in accordance with NACE <br />SP0188. Holidays shall be marked and reworked until no further holidays <br />appear. After all holiday checking is complete, the point of ground <br />connection shall be carefully coated. <br />Each coat shall be s ra ed on in accordance with the manufacturer's <br />recommendations. Rolling interior paint is not permitted. The type of spray <br />nozzle, the fluid pressure at the gun, the distance from the gun to the surface <br />being painted and the speed of travel of the gun shall be as recommended by <br />the manufacturer. Thinning shall be done as recommended. All paint in the <br />fluid pot and lines shall be cleaned out with thinner before application of the <br />paint is begun. The thinner may be used also for cleaning the painting <br />equipment at the end of each day's operations. <br />Each coat shall be dry to touch before the next coat is applied. Follow the <br />manufacturer's directions explicitly. <br />The Contractor is cautioned that small amounts of paint are intoxicating and <br />large amounts tend to be toxic. The Contractor shall make provisions to keep <br />the tank well ventilated during the spraying and drying operation to protect <br />the personnel and to facilitate drying of the coating by solvent evaporation. <br />During the actual spraying operations, all personnel within the tank shall be <br />furnished with either an appropriate respirator or source of external air such <br />as a compressed air line to a sandblasting head mask. At least two (2) men <br />shall be in the tank during spraying operations. <br />C. Exterior Area Surface Preparation & Coating: <br />(1) The work covered by this part of the specifications includes painting the <br />entire exterior surface area of the tank. It also includes painting any <br />steel outside the tank such as vents, hatches, steel retaining rings, <br />exposed yard piping and all other items outside the tank. Data Plates <br />shall NOT be painted over. The Contractor shall furnish all materials <br />required for the painting and shall install them in accordance with the <br />manufacturer's written direction and these specifications. <br />(2) The existing exterior coating system contains rg eater than 1% lead by <br />weight. A laboratory analysis of the coatings is provided at the end of <br />this document in the Appendix. Containment and lead abatement is <br />required during the exterior abrasive blasting operations. See Technical <br />Specification No. 35 - Lead Abatement (TS 35) in this document for <br />containment and lead abatement requirements. Containment must be <br />SW - 8 <br />- 439 <br />