SSPC-Guide 12 <br />June 1, 1998 <br />Editorial Revisions November 1, 2004 <br />7.1 ALL LOCATIONS <br />7.1.1 All lighting equipment must be durable and designed <br />for the intended work environment. <br />7.1.2 Portable lamps and fixtures should be encased in <br />a nonconductive, shatterproof material, which serves as an <br />electrical insulator providing additional protection from elec- <br />trical shock, abrasion, and corrosion resistance. Lamps and <br />fixtures should also be equipped with substantial guards to <br />prevent contact with personnel, containment materials, etc. <br />7.1.3 Use only heavily insulated cable with an abrasive <br />resistant casing, at least gage 14/2 SO AWG or heavier and <br />designed for hard or extra-hard usage, per NFPA 70 (e.g., <br />types S, ST, SO, STO). <br />into the specific electrical line supplying the power to the light <br />fixture. <br />8. Proper Use and Maintenance of Lighting <br />Equipment <br />8.1 LIGHTING FIXTURES <br />8.1.1 All lighting systems should be removed from the <br />direct spray of paint, abrasives, or other materials. Impacts <br />of air flow patterns from any ventilation system in operation <br />should also beconsidered. Paint overspray with accumulations <br />on fixtures reduces the amount of light emitted and restricts <br />heat dispersement of the light, which may cause premature <br />failure or overheating. <br />7.1.4 Use of white light is recommended, as it is closest to <br />natural light. White light does not visually distort the surface <br />being worked on or being inspected. Lighting equipment <br />capable of providing white light should be selected for task <br />specific lighting where practical. <br />7.2 NONHAZARDOUS, WET LOCATIONS: All lighting <br />fixtures having an electrical supply service greaterthan 12 volts <br />must be properly grounded, have ground fault circuit interrupter <br />(GFCI) protection, or have an integrated circuit breaker wired <br />8.1.2 Do not tape over the lens or cover areas designed <br />for heat dispersement, as this may cause severe damage to <br />the fixture and significantly reduces bulb life. <br />8.1.3 Do not drop or drag lighting fixtures. <br />8.2 POWER CORDS AND CONNECTORS <br />8.2.1 Periodically inspect GFCis, plugs, integrated circuit <br />breakers, and power cords, as well as all power cord connections. <br />TABLE 1 <br />WORK AREA ILLUMINATION REGIUIRMENTS IN FOOT CANDLES' <br />Minimum Recommended <br />General Work Area2 10 20 <br />Task specific - surtace preparation and coating application3 20 50 <br />Task specific - inspection 50 200 <br />Based upon levels of illumination recommended for sample occupational tasks in ANSI/IES RP 7. <br />The level of illumination throughout a work area, measured at various locations on the horizontal work-plane, at least 6 feet (2 m) <br />from the nearest light sources. (See Section 6.1). An illumination level of 20 foot candles is recommended for corridors, scaffolds, <br />and other walking surfaces. <br />The level of illumination for pertorming specific visual tasks (i.e., surface preparation, coating application, and inspection) measured <br />at the work surface in conjunction with the intended light source (See Section 6.1) <br />TABLE 2 <br />MAXIMUM LUMINANCE RATIOS' <br />Between task and adjacent darker surroundings2 <br />Between task and adjacent lighter surroundings <br />5 to 13 <br />1 to 5 <br />' Maximum luminance ratios recommended are based upon areas (indoor or outdoor) where it is completely impractical to control <br />reflectances and difficult to alter environmental conditions. <br />2 The eyes function more efticientlly and comfortably when the illumination levels within the work environments are not too different from <br />those of the seeing task. <br />3 Based upon maximum luminance ratios trom ANSI/IES RP 7 <br />52 <br />9-49 <br />