Laserfiche WebLink
SSPC-Guide 12 <br />June 1, 1998 <br />Editorial Revisions November 1, 2004 <br />in case of abnormal operations of equipment, or (b) in <br />which hazardous concentrations of gases or vapors are <br />normally prevented by positive mechanical ventilation, <br />and which might become hazardous through failure or <br />abnormal operations of the ventilation equipment, or (c) <br />that is adjacent to a Class I, Division 1 locations and to <br />which hazardous concentrations of gases or vapors might <br />occasionally be communicated unless such communica- <br />tion is prevented by adequate positive pressure ventilation <br />from asource ofclean air, and effective safeguards against <br />ventilation failure are provided. <br />Class tl locations: Class II locations are those that are <br />hazardous because ofthe presence of combustible dust. Class <br />II locations include the following: <br />Class II, Division 1: AClass II, Division 1 location is a loca- <br />tion: (a) in which combustible dust is or may be in suspen- <br />sion in the air under normal operating conditions, in quanti- <br />ties sufficient to produce explosive or ignitable mixtures; <br />or (b) where mechanical failure or abnormal operation of <br />machinery or equipment might cause such explosive or <br />ignitable mixtures to be produced, and might also provide <br />a source of ignition through simultaneous failure of electric <br />equipment, operation of protection devices, or from other <br />causes, or (c) in which combustible dusts of an electricaliy <br />conductive nature may be present. <br />Class II, Division 2: A Class II, Division 2 location is a <br />location in which: (a) combustible dust will not normally <br />be in suspension in the air in quantities sufficient to <br />produce explosive or ignitable mixtures, and dust accumu- <br />lations are normally insufficient to interfere with the normal <br />operation of electrical equipment or other apparatus; <br />or (b) dust may be in suspension in the air as a result <br />of infrequent malfunctioning of handling or processing <br />equipment, and dust accumulations may be ignitable by <br />abnormal operation or failure of electrical equipment or <br />other apparatus. <br />Class III locations: Class III locations are those that are <br />hazardous because of the presence of easily ignitable fibers <br />or flyings (e.g., dust) but in which such fibers or flyings are <br />not likely to be in suspension in the air in quantities sufficient <br />to produce ignitable mixtures. Class III locations include the <br />following: <br />Class III, Division 1:ACIass III, Division 1 location is a loca- <br />tion in which easily ignitable fibers or materials producing <br />combustible flyings are handled, manufactured, or used. <br />Class III, Division 2: A Class III, Division 2 location is a <br />location in which easily ignitable fibers are stored or <br />handled, except in process of manufacture. <br />Note: The above definitions of hazardous (classified) loca- <br />tions are taken directly from 29 CFR 1926.449. Refer to the <br />OSHA standard for additional information and examples for <br />each classification. <br />Hazardous Atmosphere: An atmosphere that may <br />expose employees to the risk of death, incapacitation, impair- <br />ment of ability to self-rescue (that is, escape unaided from a <br />permit space), injury, or acute illness from one or more of the <br />following causes: (1) flammable gas, vapor, or mist in excess <br />of 10 percent of its lower flammable limit (LFL); (2) airborne <br />combustible dust at a concentration that meets or exceeds its <br />LFL; (3) atmospheric oxygen concentration below 19.5% or <br />above 23.5%; (4) atmospheric concentration of any substance <br />for which a dose or a permissible exposure limit is published <br />in subpart G, Occupational Health and Environmentai Control, <br />or in subpart Z, Toxic and Hazardous Substances, which could <br />result in employee exposure in excess of its dose or permis- <br />sible exposure limit; (5) any other atmospheric condition that is <br />immediately dangerous to life or health. NOTE: This definition is <br />taken directly from 29 CFR 1910.146. For the purposes of this <br />guide, onlythose considerations in selecting lighting dealing with <br />the concentrations of flammable vapors or combustible dusts <br />[items (1) and (2) above] are addressed. The reader is cautioned <br />to consider all other aspects of a hazardous atmosphere as <br />described above. <br />lower Flammable Limit: The lower limit of flammability of <br />a gas or vapor at ordinary ambient temperatures expressed in <br />percent of the gas or vapor in air by volume. Lower Flammable <br />Limit is synonymous with Lower Explosive Limit. <br />A.3 EVALUATION OF WORK SITES: Before any aspect <br />of an industrial painting project commences, the location must <br />be evaluated to determine whether a hazardous atmosphere <br />exists. This evaluation involves a thorough inspection of the <br />work location and often includes both a visual inspection and <br />monitoring for atmospheric hazards. <br />OSHA's permit-required confined space standard (29 CFR <br />1910.146) requires that employers test and monitor spaces with <br />instruments which detect all aspects of hazardous atmospheres <br />that may be encountered. OSHA has classified atmospheric <br />hazards into three categories: toxic; asphyxiating; and flam- <br />mable or explosive atmospheres. Monitoring tests are typi- <br />cally performed using a direct reading instrument which gives <br />an instantaneous assessment of the degree of atmospheric <br />hazard. <br />From a lighting perspective, the minimum required tests in <br />any suspect hazardous atmosphere include oxygen level, the <br />concentration of flammable gases or vapors, and the concentra- <br />tion of combustibie dust. <br />A.4 SURVEY CONSIDERATIONS: Initial testing for hazards <br />may not be enough. Periodic or continuous testing may be <br />req uired, as conditions can change and become hazardous during <br />the painting project. Conditions may also vary throughout a work <br />space. Concentrations of flammable gases and vapors may vary <br />depending on their physical characteristics (i.e., heavier gases <br />may tend to concentrate near the bottom of tightly sealed spaces <br />while light gases may concentrate near their emission source <br />or near the top of the space). With this in mind, a monitoring <br />strategy must be developed which takes into account both the <br />physical properties of potential atmospheric hazards and the <br />physical characteristics of the structure. The instrumentation <br />9-51 529 <br />