2060 RES CITY COUNCIL AT REGULAR MEETING ON 8TH DAY OF SEPTEMBER 1980 APROVED ADVERTISEMENT FOR BIDS
City-of-Paris
>
City Clerk
>
Resolutions
>
1889-2010
>
1930-1999
>
1980-1989
>
1980
>
2060 RES CITY COUNCIL AT REGULAR MEETING ON 8TH DAY OF SEPTEMBER 1980 APROVED ADVERTISEMENT FOR BIDS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2017 9:05:14 AM
Creation date
7/27/2012 4:35:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - Date
10/13/1980
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TECHNICAL SFECIFICATIONS <br />FOR <br />FIBERGLASS FUEL STOf2AGE TANK <br />PART I GENEf2AL <br />1.01 RELATED FdQRK <br />A. Cast-in-place, 3000 P.S.I. 12-inch Concrete Floor. <br />B. Eye - Bolts shall be 12-inch with 6-inch in concrete, see Plan. <br />C. Other related work - excavation, ballast material, backfill, <br />steel pipe outlets for vent, filler and dispersing system. <br />1.02 QUALITY ASSURANCE <br />A. Acceptahle Manufacturers: Owens-Corning "Fiberglas" or like <br />items. <br />B. Governing Standards: <br />1. Proposed ASTM Standard Draft No. ld, dated September 15, 1977. <br />2. Underwriters I,aboratories, Tr,c. (U.L. ) <br />File M H 7991 dated October 13, 1965. <br />For storage of flammable liquids as updated under U.L. <br />Follow-up Service in letter of January 15, 1976. <br />3. National Fire Protection Association (NFPA 30) Flammable and <br />Combustible Liquids Code and (NFPA 31) Standard for In- <br />stallation of oil burning eguipment. <br />PART II PRODUCTS <br />2.01 Fiberglass-reinforced polyester underground storage tank. <br />A. Loading Conditions - Tank shall meet the following design criteria: <br />1. External hydrostatic pressure: Buried in ground with 3" of <br />overburden over top of tank, or as shown on Plans. The hole <br />fully flooded and a safety factor of 2:1 against general <br />buckling. <br />2. Internal Loads: Tank shall withstand 3-5 P.S.I. Air Pressure <br />Test with a 5 to 1 safety facter.. Test prior to installation, <br />Since the design conditions to t.est for leakage. <br />3. Tank shall be designed to snpport accessory equipment such as <br />Urap Tubes etc. when installed according to manufacturer's <br />r.ecommendations. <br />TS-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.