Laserfiche WebLink
commissioner by rule may supplement the building specifications in the plan of operation with the <br />structural provisions of the International Residential Code. Roofing materials satisfy the building <br />specifications in the plan of operation if those materials pass the UL Standard 997 or a <br />comparable test certified by the Board and are installed as required by the Board to promote the <br />wind resistance of the materials. A structure constructed, repaired, ar to which additions were <br />made before January 1, 1988, that is located in an area covered at the time by a building code <br />recognized by the Association shall be considered an insurable property for windstorm and hail <br />insurance from the Association without compliance with the inspection or approval requirements <br />of this Section or the plan of operation. A structure constructed, repaired, ar to which additions <br />were made before January 1, 1988, that is located in an area not covered by a building code <br />recognized by the Association shall be considered an insurable property for windstorm and hail <br />insurance from the Association without compliance with the inspection or approval requirements <br />of this Section or the plan of operation if that structure has been previously insured by a licensed <br />insurance company authorized to do business in this State and the risk is in essentially the same <br />condition as when previously insured, except for normal wear and tear, and without any structural <br />change other than a change made according to code. Evidence of previous insurance includes a <br />copy of a previous policy, copies of canceled [ya4icalled] checks or agenYs records that show <br />payments for previous policies, and a copy of the title to the shucture or mortgage company <br />records that show previous policies. After January 1, 2002, a person must submit an application <br />for windstorm inspection to the unit responsible for windstorm inspection at the deparhnent before <br />beginning to construct alter, remodel, enlarge, or repair a structure. Failure to submit a timely <br />application may result in a certificate of compliance not being issued unless plans and <br />calculations, testing information, manufacturer's installation instructions, or any other <br />documentation required by the commissioner is submitted to the unit responsible for windstorm <br />inspection at the department as may be requested in order to fulfill the requirements of this <br />section. The Board may appoint or employ qualified inspectors as defined in this Section to <br />perform any inspections required by this Section. <br />