(2) Reduced pressure principle backflow prevention assemblies may be used if- <br />(A) the device is installed at a minimum of 12 inches above ground in a location <br />that will ensure that the assembly will not be submerged; and <br />(B) drainage is provided for any water that may be discharged through the <br />assembly relief valve. <br />(3) Pressure vacuum breakers may be used if. <br />(A) no back - pressure condition will occur; and <br />(B) the device is installed at a minimum of 12 inches above any downstream <br />piping and the highest downstream opening. Pop -up sprinklers are measured from <br />the retracted position from the top of the sprinkler. <br />(4) Atmospheric vacuum breakers may be used if: <br />(A) no back - pressure will be present; <br />(B) there are no shutoff valves downstream from the atmospheric vacuum <br />breaker; <br />(C) the device is installed at a minimum of six inches above any downstream <br />piping and the highest downstream opening. Pop -up sprinklers are measured from <br />the retracted position from the top of the sprinkler; <br />(D) there is no continuous pressure on the supply side of the atmospheric vacuum <br />breaker for more than 12 hours in any 24 -hour period; and <br />(E) a separate atmospheric vacuum breaker is installed on the discharge side of <br />each irrigation control valve, between the valve and all the emission devices that <br />the valve controls. <br />(c) If there are no conditions that present a health hazard, a double check valve backflow <br />prevention assembly may be used, and shall be installed in accordance with the manufacturer's <br />instructions. <br />If a double check valve is installed below ground: <br />(1) test cocks shall be plugged, except when the double check valve is being <br />tested; and <br />(2) test cock plugs shall be threaded, water - tight, and made of non - ferrous <br />material; and <br />(3) a Y -type strainer shall be installed on the inlet side of the double check valve; <br />and <br />(4) there shall be a minimum 6 inch clearance between any fill material and the <br />bottom of the double check valve to allow space for testing and repair; and <br />(5) there shall be space on the side of the double check valve to test and repair the <br />double check valve; and <br />(6) double check valve shall be 12 inches minimum below grade; and <br />(7) double check boxes shall be 18 inches minimum deep with a pea gravel base <br />at least 4 inches deep; and <br />(8) double check boxes shall not be placed with any public right of way and shall <br />be as near as possible to the water meter. <br />