Laserfiche WebLink
Innovative approaches . . <br />trs � <br />ireese ..w Nichols <br />practical results <br />Timothy E. Campbell, P.E. <br />Electrical /SCADA <br />Years Experience: 12 <br />Registrations: Professional Engineer, Texa: <br />Education: B.S., Electrical Engineering, <br />:sZJ8 <br />1996 ( #81011) <br />Texas A &M University, 1990 <br />Mr. Campbell is experienced in electrical design; project management, coordination <br />of mechanical and electrical disciplines, and vulnerability assessments and <br />emergency operations planning. He has a background in design of electrical and <br />instrumentation for water treatment plants, wastewater treatment plants, and water <br />distribution. He is also skilled in the electrical design of commercial and industrial <br />facilities. <br />Project Experience: <br />Water System Vulnerability Assessments - Brown County WID #1 and the <br />Cities of Abilene, Beaumont, Carrollton, Denton, Corpus Christi, Garland, Irving, <br />Midlothian, Plano, North Richland Hills, San Angelo and Temple, Texas. Reviewed <br />Water Utility Vulnerability Assessments related to power instrumentation and SCADA. <br />Provided not only recommendations for physical improvements, but also operational <br />and procedure changes. <br />Wastewater Treatment Plant - City of Son Angelo, Texas - Design of plant <br />improvements including new headworks, odor control, digesters, sludge handling, <br />gravity belt thickener. The anaerobic digester gas was collected and used to feed the <br />boiler. <br />Wastewater Treatment Plant - City of Beaumont, Texas - Provided the electrical <br />design for the complete replacement of the electrical system for the plant. The <br />existing system was outdated and several portions were not operable due to the <br />extreme corrosion. A new looped primary feed system was installed that fed motor <br />control centers inside air- conditioned enclosures to protect them from the hydrogen <br />sulfide. The motor control centers and various electrical distribution equipment are <br />housed in temperature controlled, prefabricated, 304 stainless steel buildings to <br />protect the equipment from the corrosive environment. <br />Water Treatment Plant - City of Midland, Texas - Designed chemical feed <br />improvements, including chlorine storage and feed system. The $1.2 million <br />improvements included both chlorine and ammonia scrubber systems for the feed <br />and storage facilities. <br />Nitrate Treatment and Other Water System Improvements - City of Vernon, <br />Texas - Provided electrical and instrumentation design for the installation of the Ion <br />Exchange Treatment Plant, elevated storage tank, new well sites and chlorine <br />injection. This project included providing SCADA for the City, containing installation <br />of radio equipment for 34 well sites, and 12 sanitary sewer lift stations. <br />Water Treatment Plant - City of Beaumont, Texas - Designed plant expansion <br />including new filters, pulsators, and chemical feed. Plant capacity was increased to <br />14 MGD. <br />Water System Vulnerability Assessment and Emergency Response Plan <br />