Laserfiche WebLink
<br />. , <br />}l\ <br />~. <br />MEMORANDUM ,. <br /> <br />TO: <br /> <br />Mayor and City Council <br />Planning and Zoning Commission <br /> <br />Shawn Napier, P.E f\ <br />City Engineer / Di j r o,PubJic Works <br /> <br />July 6, 2006 <br /> <br />FROM: <br /> <br />DATE: <br /> <br />SUBJECT: Master Plat for The Hills Subdivision <br /> <br />I have reviewed the master plat of the above referenced addition. It appears that the master plat <br />complies with the City of Paris subdivision regulations with the following exception. <br /> <br />1. Provide a contact person for the developer. <br />2. Label all Right-of-Ways (ROW) that are not 50-feet wide. <br />3. Show all proposed storm sewer and drainage structures. <br />4. All drainage areas that point discharge off site will require an off-site drainage easement <br />from the adjacent property owner. <br />5. Provide a column in the Drainage Data table that tells the termination point of all the <br />drainage areas. <br />6. Provide more details on proposed inlets locations and sizes. <br />7. Clearly define the drainage areas and remove the phasing information. <br />8. Provide a second sheet for everything but drainage with no contours. <br />9. In the General Notes #5 add "a minimum" in front of 25-foot. <br /> <br />I recommend approval of the master plat upon completion of the above items. <br /> <br />cc: Tony N. Williams, City Manager <br />Lisa Wright, Director of Community Development <br />Brandon Chaney, P.E., R.P.L.S., Chaney Engineering, Inc. <br />Wayne Brown <br /> <br />r- <br />