2009-055-RES-Master plan for Paris Wastewater treatment plantRESOLUTION NO. 2009-055
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF PARIS, TEXAS,
ACCEPTING THE PROPOSAL OF HAYTER ENGINEERING, INC. FOR
EIVGINEERING SERVICES TO DEVELOP A MASTER PLAN FOR THE CITY
OF PARIS WASTEWATER TREATMENT PLANT AND AUTHORIZING THE
EXECUTION OF AN ENGINEERING SERVICES AGREEMENT; MAKING
OTHER FINDINGS AND PROVISIONS RELATED TO THE SUBJECT; AND
DECLARIIVG AN EFFECTIVE DATE.
WHEREAS, on September 17, 2008, the City Council of the City of Paris, Texas,
passed City Ordinance No. 2008-029 authorizing the funding for the development of a
master plan for the City of Paris waste water treatment facility; and,
WHEREAS, the City has received a proposal from Hayter Engineering, Inc. to
provide engineering services to develop a master plan for the City of Paris Wastewater
Treatment Plant, for an amount not to exceed $59,785.00, as described in the proposal
attached here to as Exhibit A; and
WHEREAS, it is deemed appropriate that the proposal of Hayter Engineering, Inc. to
provide engineering services for plans and specifications for these projects be approved
and the City Manager be authorized and directed to negotiate and execute on behalf of the
City of Paris a professional services agreement with Hayter Engineering, Inc. in a form
substantially similar to the form attached hereto as Exhibit B.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
PARIS, TEXAS:
Section 1. That the findings set out in the preamble to this resolution are hereby in
all things approved.
Section 2. That the proposal of Hayter Engineering for engineering services for the
development of a Master Plan for the City of Paris Wastewater Treatment Plant for an
amount not to exceed $59,785.00, be, and the same is hereby accepted.
Section 3. That the City Manager be, and he is hereby authorized and directed to
negotiate and execute on behalf of the City of Paris an Engineering Services Agreement
with Hayter Engineering, Inc. for plans and specifications for the above referenced water,
sewer and roadway replacement projects, under the terms and conditions and in a form
approved by the City Attorney.
Section 4. That this resolution shall be effective from and after its date of passage.
PASSED AND APPROVED this 26th day of May, 2009.
~a~nh
sse Jam Freelen, Mayor
ATTEST:
nice Ellis, City Clerk
APPROVED AS TO FORM:
~~2 -
W. Kent McIlya C' Attorney
WASTEWATER TREATMENT PLANT
PLANNING PROPOSAL
for THE CITY OF PARIS
March 2009
N HAYTER
ENGINEERING, INC.
CONSULTANTS PLANNERS ENGINEERS
4445 S.E. LOOP 286
PARiS, TEXAS 75460
sos) 7as-o~
E X H I B I T~ Q ~AX (903) 785-0308
' HAYTER
' ENGINEERING, INC.
CONSULTANTS PLANNERS ENGINEERS
~
'
4445 S.E. LOOP 286
PARIS, TEXAS 75460
(903) 785-0303
FAX (903) 785-0308
March 30, 2009
Mr. Shawn Napier, P.E.
City Engineer
City of Paris -
P.O. Box 9037
Paris, TX 75461
Re: Wastewater Treatment Plant Planning Proposal ,
Dear Mr. Napier:
This letter provides our proposal for professional engineering services in the development of a
master plan for the City's wastewater treatment facility. We appreciate the confidence that you
have shown in our firm in selecting us for this contract negotiation, and we look forward to
workirig with you for a successful project.
The information which follows contains our proposed scope of services, resumes for key
individuals, our certificate of liability insurance, and a proposed fee. Should you require any
further information please let me know.
Sincerely,
GINEERING, INC.
R. Reeves H
President
Enclosures
E.
Service Since 1957 1
TBPE F-000315
SCOPE OF SERVICES
~ The completed plan will be presented as a bound, written report which will identify the current
wastewater treatment capabilities and future treatment needs of the City, and develop location
and design parameters for expanded facilities. The report will include necessary maps and
~ drawings in multiple copies as needed. The project will begin in April of 2009, and the finished
report will be delivered by April, 2010. Presentations to the Council or staff will be included as
~ necessary. The plan will include information as follows:
~
1. Introduction.
2. Community Settin . A description of Paris and Lamar County, to include data which may
tion would include
f
l i
~
orma
n
be of use in developing new treatment facilities. Typica
soils information, air and
ical data
limatolo
l
,
g
ceup, c
historical growth trends, industrial ina
~
water quality, and base mapping.
Existin Treatment Facilities. This section would include a history of the plant. The
3
US Army
th
'
~
.
e
s as
existing treatment plant was deeded to the City in the 1950
lant was upgraded in 1971 and in the 1980's. The
The
M
p
axey.
decommissioned Camp
it was originally for a secondary treatment limit, which has been enhanced
'
~
s perm
City
over the years as environmental constraints increase. Historical influent data will be
timate for the strength of the waste
tabulated to show trends and to develop a consistent es
ld be tabulated to show the range of
which must be treated. Historical effluent data wou
eatment
t
in
i
om
ro
t
p
~
r
st
g
flows and the efficacy of the ex
whi h
curret standards,
r
de
will allo~'
f each u
analyzed to show the capacity o
identification of "weak links" in the current process.
~
lift station also dates tothe City's acquisition of the plant from the US Army.
The master
This section of the report would include overflow and outage history, as well as
~
nance history on the existing facility, and a condition analysis.
t
i
e
n
ma
f observations from interview with the
Finally, this section would include a summary o
~
current operating staff.
~
4. Future service area and population• This section of the report will develop future
in particular utilizing wark done by the Pat Mayse Study
estimates
ti
l
,
on
a
popu
ulation and water demands. Consideration will be given to the
o
ture
f
f
p
p
u
or
Committee
City's historic growth trends to develop an idea of the future wastewater treatment service
,
area.
~ 5. Physioaraphic relationship of the lp nt to the service area. The existing treatment plant
owes its location to its original development by the US Army to serve Camp Maxey.
~
2
0
Subsequently the plant was transferred to the City of Paris for a nominal sum, which
made it cost-effective to construct the original 5-mile outfall main from the City to the
plant. The plant location has remained the same since the outfall main and lift station
were existing. The master lift station is now in need of serious rehabilitation and/or
replacement, and the existing plant site is substantially occupied by existing structures. It
may be feasible to move the plant closer to the community, or further down Pine Creek.
This section would explore the pros and cons of relocating the plant to different areas
considering the ultimate service area developed earlier in the report.
6. Future influent stren th. City staff collects data regarding the strength, quantity, and
various constituents of the incoming wastewater. An industrial pretreatment ordinance
penalizes industries which contribute waste which differs significantly from the normal
domestic waste. The report would develop a recommendation for the future wastewater
quality which should be used for design of the treatment facilities.
7. Future ep rmit trends. In the late 1970's when the plant was originally developed, the
TCEQ permit required approximately 85% reduction in BOD and TSS parameters. In
subsequent permits these limits were tightened to require 90% removal, and then 95%
removal, of the BOD. In addition to the original parameters the State now limits ammonia
nitrogen in the discharge_ as well as pH and dissolved oxygen. This portion of the report
would involve contact with the TCEQ permit team to determine any future permit
parameters which may need to be considered in the treatment process.
8. Overview of site alternatives. In this section the scenarios which appear lilcely after
consideration of paragraphs 1 through 7 would be compared. These may include a)
remodeling the existing plant; b) construct a new plant at the existing site; c) construct a
new plant downstream along Pine Creek; d) construct a new plant in some other drainage
basin; e) sludge disposal needs; and 0 power requirements for each alternative and access
during flooding.
9. Once site alternatives have been evaluated, process alternatives will be evaluated. It is
likely that the City will remain with some variation of an "activated sludge" process, but
the various types can involve different pretreatment options, tankage aeration systems,
and other options. A series of alternatives would be considered both for the wastewater
itself, and for sludge processing. Preliminary layouts for each of these alternatives would
be developed, together with life-cycle cost projections.
All of the above would be compiled into a written report with illustrations as necessary. The
draft report would be reviewed with the plant staff and be amplified or revised as necessary to
address their concerns. The draft report would be reviewed with the City Council and a final
report would be developed.
~
~
R. Reeves Hayter, P.E., R.P.L.S.
President, Hayter Engineering, Inc.
Texas Registration 440334
Education
B.S.E. Civil Engineering Duke University, 1971
Registrations
Professional Engineer, 1976, Texas
Professional Engineer, 1976, Oklahoma
Professional Engineer, 1976, Missouri
Professional Engineer, 1976, Arkansas
Professional Engineer, 1976, New Mexico (inactive)
Professional Engineer, 1976, Louisiana (inactive)
Registered Professional Land Surveyor, 1980, Texas
Memberships
National Society of Professional Engineers
Texas Society of Professional Engineers
American Society of Civil Engineers
Water Environment Federation
American Water Works Association
Southern Building Code Congress
Experience
Mr. Hayter has 35 years experience in surveying, consulting, planning, design, testing,
construction review, operations and environmental reviews for a broad cross-section of civil
works. Prior to his association with Hayter Engineering, he served as an assistant City engineer
and as project representative for an ENR 500 engineering design firm. Mr. Hayter became
associated with Hayter Engineering in 1976, and, since 1986, has served as President of the firm.
Among his prior projects are:
WASTEWATER FACILITIES
► Wastewater Treatment Facility Expansion, City of Bonham, Texas
► Wastewater Treatment Facility, City of Tioga, Texas
► Stormwater Equalization Basin, City of Commerce, Texas
► Wastewater Chlorination/Dechlorination Facilities, City of Paris, Texas
► 15" Powder Creek Interceptor Facilities, City of Bonham, Texas
► Wastewater Collection System Rehabilitation, City of Trenton, Texas
► Class A Autothermal Sludge Digestion Facilities, City of Paris, Texas
► Wastewater Treatment Facility Expansion, City of Cooper, Texas
4
7
m
I
AIRPORT DEVELOPMENT PROJECTS
► Coinmerce Municipal Airport-Runway and apron improvements.
► Cox Field, Paris, Texas - T-Hangar Aprons
► Cox Field, Paris, Texas - Taxiway Design
► Jones Field, Bonham, Texas - Aviation easements, airport layout planning
► Cox Field, Paris, Texas - Runway and taxiway reconstruction, navaids,
iighting improvements; airport layout plan
DRAINAGE PLANNING AND DESIGN
► Master Drainage Plan, City of Paris, Texas
► Comprehensive Plan - Stormwater Drainage, City of Bonham, Texas
► Master Drainage Plan, City of DeKalb, Texas
► Master Drainage Plan, Stillhouse Estates, Paris, Texas
► Master Drainage Plan, City of Reno, Texas
► Drainage Facilities Design, Mirabeau Center Project, City of Paris, Texas
► Drainage Facilities Design, Pine Mill Road Project, City of Paris, Texas
► Plum Street Stormwater Detention Basin, City of Paris, Texas
STREETS ROADS - SIDEWALKS
► Urban Renewal, St. Joseph, Missouri
► Airpark Avenue, Greenville EDC, Texas
► 7th Southwest Project, City of Paris. Texas
► Pine Mill Road Improvements, Lamar County, Texas
► Oak Creek Addition, Phase VII, Paris, Texas
► Townwood Estates, Paris, Texas
► Pecan Street Extension, City of Bonham, Texas
► City of Clarlcsville, 1992 TDHCA Street Improvements, Texas
► Silo Road, Bonham, Texas
BRIDGES
► Mustang Creek, City of Deport, Texas
► Pig Branch, City of Bonham, Texas
► BRINSAP, approximately 800 bridges in Missouri and Texas
5
WATER FACILITIES
► LCWSD 1998-99 Improvements, Elevated Storage and Transmission
Mains
► Water Treatment Facilities, City of Cooper, Texas
► 4 Million gallon Center Street Storage, City of Paris, Texas
► Elevated storage facilities, City of Bonham, Texas
► Elevated storage facilities, Lamar County Water Supply District
(10 tanks total)
► Deep water well, City of Trenton, Texas
► Deep water well, City of Wolfe City, Texas
► Comprehensive Water Supply Plan, City of Reno, Texas
► Dam rehabilitation, Big Creelc Reservoir, City of Cooper, Texas
► Elevated Storage Facilities, Sharon WSC
► Elevated Storage Facilities, Bright Star-Salem WSC
► Elevated Storage Facilities, City of Tioga, Texas
COMMERCIAL/INSTITUTIONAL DEVELOPMENT
► Applebee's Restaurant, Paris, Texas
► Lamar Crossing Shopping Center, Paris, Texas
► Kennedy Ford-Lincoln Dealership, Paris, Texas
► Commerce High School, Commerce, Texas
► Burger King, Bonham, Texas
► Mirabeau Square Shopping Center Expansion, Paris, Texas
► Holiday Inn Express and Comfort Suites, Paris, Texas
► IHOP Restaurant, Mt. Pleasant, Texas
► Brentwood Terrace Nursing Facility, Paris, Texas
6
Michael N. Tibbets, P.E.
Hayter Engineering, Inc.
Edztcation
B.S.C.E., Civil Engineering
M.S.C.E., Civil Engineering
Texas A& M University, 1983
Texas A& M University, 1986
Registrations
Professional Engineer, 1989, Texas
Memberships
National Society of Professional Engineers
Texas Society of Professional Engineers
Experiences
Mr. Tibbets has experience in planning, design and construction review for a variety of
civil works. Prior to his association with Hayter Engineering, he was the assistant to the City
Engineer for the City of Paris for four years, and a research assistant with the Texas Water
Resources Institute in College Station, Texas for 18 months. Mr. Tibbets has been associated
with Hayter Engineering since 1989. Among his prior projects are:
WASTEWATER FACILITIES
► City of Paris, Texas, Clarifier and Sludge Facility Expansion
► City of Reno, Texas, Wastewater Treatment Plant Expansion
► City of Arp, Texas, Wastewater Treatment Plant Expansion
► City of Arp, Texas, Wastewater Interceptor Mains
► City of Howe, Texas, Wastewater Collection System Rehab
► Oak Creelc Addition, Phase IV through VI, Paris, Texas
► City of Paris, Texas, 12`h S.E. Wastewater Collection Replacement
► City of Malakoff, Texas, Mitchum Street Sewer Line Extension; Lift
Station Replacement
► City of Trinidad, Texas, Urgent Need Sewer Line Replacement, Water and
Sewer System Improvements
► Jarvis Christian College, Hawkins, Texas, WWTP Chlorine Contact
Chamber
► City of Commerce, Texas, Screenings Conveyor/Compactor at WWTP
► City of Edgewood, Texas, WWTP Disk Aerator Replacement, Sludge
Drying Beds
► City of Paris, Texas, Sludge Disposal Project
► City of Paris, Texas, Southeast Force Main
► City of Avery, Texas, South Lift Station Replacement
► City of Cooper, Texas, Highway 24 Lift Station and Lines
► City of Commerce, Texas, Sludge Lagoon and WWTP Renovations
► City of Trinidad, Texas, Sewage System Improvements
► City of Malakoff, Texas Water and Wastewater System Improvements
7
► City of Avery, Texas, WWTP Improvements
► City of Annona, Texas, Lines and Lift Station on Old English Road
► City of Annona, Texas, Lines and Lift Station, 2001 ORCA project
► Ennis Tag and Label, Ennis, Texas, Lines and Lift Station
► City of Detroit, Texas, Wastewater Treatment Plant Renovation
► Rivercrest ISD, Bogata, Texas WWTP troubleshooting / recommendations
► City of Commerce, Texas, Valve Replacement at the WWTP master lift
station
► City of Comrnerce, Texas, Wastewater Collection System Improveinents
PAVING DESIGN
► Oalc Creek Phase V, Paris, Texas
► City of Paris, Texas, Asphaltic Overlay Program
► City of Clarksville, Texas, 1994 Street Paving Improvements
► City of Clarksville, Texas, 1997 Paving and Drainage Project
► Paris Housing Authority, Paris, Texas
► City of Trinidad Economic Development Corporation, Trinidad, Texas,
Paving and Drainage Improvements
DRAINAGE PLANNING AND DESIGN
► Master Drainage Plan, Oak Creek Addition, Paris, Texas
► Drainage Facilities Design, Oak Creek Addition, Paris, Texas
► Stormwater Detention Basin, Stillhouse Estates, Paris, Teaas
► Drainage Facilities Design, Townwood Estates, Paris, Texas
► City of Paris, Texas, 24th SE Drainage Project
► Drainage Facilities Design, Main Street, City of Farmersville, Texas
► McGrew Creek Floodplain Analysis, City of Greenville, Texas
► Cumby ISD, Cumby, Texas, 24" storm sewer for new high school
► City of Van Alstyne, Texas, Greywood Heights Paving and Drainage
Iinprovements
► City of Edgewood, Texas, ORCA Paving and Drainage Iinprovements
► Lone Oak ISD, Lone Oak, Texas, Paving and Drainage Improvements
► Detroit ISD, Detroit, Texas, New High School Gymnasium Paving and
Drainage Improvements
BRIDGE INSPECTION
► 1996 Atlanta District, On-System
► 1994 Atlanta District, On-System
► 1994 Paris District, Off-System
► 1990 Hunt and Rains Counties
► 1991 Lamar and Red River Counties
8
WATER FACILITIES
► Gity of Wolfe City, Texas, Water Treatment Facilities Renovation
► City of Wolfe City, Texas, Water Treatment Improvements
► City of Commerce, Texas, Water Treatment Plant Expansion
► South Franklin WSC, Mt. Vernon, TeYas, Water Treatment Plant, Lines,
Standpipes
► City of Star Harbor, Malakoff, Texas, Water Treatment Plant, Lines,
Standpipe
► City of Trinidad, Trinidad, Texas, Water Treatment Plant, Disinfection
System Modifications
► City of Malakoff, Texas, Water Treatment Plant, Raw Water Pump
Station, Lines
► Nevada WSC, Nevada, Texas, Pump Station
► Gafford Chapel WSC, Sulphur Springs, Texas, Lines, Pump Station
► City of Arp, Texas, Lines, Pump Station ll Water
► City of Commerce, Texas, Hwy 24 Water Line Relocation, Hwy
Line
► City of Paris, Texas, Center Street Pumping Facilities
► City of Wolfe City, Texas, Water Distribution Improvements
► City of Emory, Texas, Water Distribution Improvements
► City of Paris, Texas, Center Street 18" Water Line
► Disinfection Contact Time Analyses for Bonham, Cooper, SFWSC, Wolfe
City, Emory, Commerce, Community WSC, West Tawalconi, Star Harbor,
Trinidad, Golden WSC, Edgewood, Malakoff, and Point, Texas
► Chloramine disinfection conversion for Bonham, Cooper, Wolfe City,
Emory, Commerce, Trinidad, and Edgewood, Texas
► City of Josephine, Texas, Elevated Storage Tanlc
► City of Cooper, Texas, Elevated Storage Tank
► City of Edgewood, Texas, Elevated Storage Tank
► South Franklin WSC, Mt. Vernon, Texas, Elevated Storage Tank
► City Van Alstyne, Texas, CGMA Point of Take and Distribution System
Improvements
► MJC WSC, Pattonville, Texas, ORCA Water System Improvements
► City of Wolfe City, Texas, City Reservoir Dam Rehabilitation
Water Treatment Seminars:
New Disinfection By-Product Rule and Surface Water Treatment
Rule: Operational Issues and Treatment Strategies
Drinlcing Water Teleconference
Water Treatment Plant Taste and Odor AWWA teleconference
Alternative Disinfection Choices for the Future teleconference
Membrane Technology Conference San Antonio
Emerging Treatment Technologies
November 1999
August 2000
November 2000
March 2001
March 2001
November 2002
9
WATER AND WASTEWATER PROJECTS
► Farmersville 1990 TDHCA
► Avery 1996 TDHCA
► Trinidad 1996 TDHCA
► Paris Housing Authority 1994
Publications
"Optimum Reservoir Operation for Flood Control and Conservation Purposes", Technical
Report 137, Texas Water Resources Institute, 1985, Wurbs, Cabezas, Tibbets; "Seasonal Rule
Curve Operation", ASCE Symposium, Engineering Hydrology Proceedings, August 1987,
Wurbs and Tibbets and State-of-the-Art Review and Annotated Bibliographv of Svstems
Analysis Techniques Applied to Reservoir Operation, Texas Water Resources Institute,
Technical Report 136, 1985, Wurbs, Cabezas, Tibbets, Roy, Feasibility of Seasonal
Multipurpose Reservoir Operation in Texas, Texas A&M University, May 1986.
10
Michael J. Donnan, P.E.
Hayter Engineering, Inc.
Educatiosz
B.S.C.E., Civil Engineering, Virginia Military Institute, 1980
Registrations
Professional Engineer, 1988, Texas
Meinberships
National Society of Professional Engineers
Texas Society of Professional Engineers
AmeTican Society of Professional Engineers
Experiences
Mr. Donnan has some 25 years experience in consulting, planning, design, construction
review, bridge inspection, operations and environmental reviews for a wide range of civil works.
Prior to his association with Hayter Engineering, Inc., he served as an officer in the U.S. Army
Corps of Engineers. Mr. Donnan became associated with Hayter Engineering, Inc. in 1983, and,
since 1988 has served as a Project Manager. Among his prior projects are:
WASTEWATER FACILITIES
► Wastewater Treatment Facility Expansion, City of Emory, Texas
► Wastewater Treatment Facilities Improvement, City of Point, Texas
► South Wastewater Interceptor Replacement, City of Bonham, Texas
► Wastewater Collection System Improvements, City of Trenton, Texas
► Wastewater Collection System Improvements, City of DeKalb, Texas
► Southwest Interceptor and Lift Station, City of Cooper, Texas
► Wastewater Collection Replacement Lines S.E. Lift Station, City of Paris,
Texas
► Stormwater Holding Pond, City of Commerce, Texas
► Stormwater Holding Pond and Return Pumping Facilities, City of Trenton,
Texas
► Wastewater Collection System Improvements, City of Commerce, Texas
► Wastewater Collection System Improvements, City of Deport, Texas
► Wastewater Collection System Improvements, City of Blossom, Texas
► Wastewater Collection System Improvements, City of Emory, Texas
► Wastewater Collection System Iinprovements, City of Cooper, Texas
► Wastewater Collection System Improvements and Lift Station, City of
Edgewood, Texas
11
► Wastewater Lift Stations, City of Emory, Texas
► Manhole Rehabilitation, City of DeKalb, Texas
► Wastewater Treatment Facilities, City of East Tawakoni, Texas
► Force Main Replacement, City of East Tawakoni, Texas
► Lift Station, Force Main, and Gravity Sewer, Trenton ISD, Texas
► Wastewater Treatment Facilities, City of Winnsboro, Texas
MASTER PLAN
► City of East Tawakoni, 2000
► City of DeKalb, 2002
► Golden Water Supply Corporation, 1998
► City of Trenton, 2007
DRAINAGE PLANNING AND DESIGN
► Master Drainage Plan, City of Edgewood, Texas
► Master Drainage Plan, City of Point, Texas
► Durham Homes Drainage Improvements, City of Commerce, Texas
WATER FACILITIES
► 1998-99 LCWSD Water Improvements - Pumping Facilities
► Water Treatment and Pumping Facilities, City of Emory, Texas
► Deep Water Well, Lake Fork Water Supply Corporation, Texas
► Deep Water Well, City of Alba, Texas
► Water Transmission Main, City of Alba, Texas
► Booster Pumping Facility and 1 Million Ground Storage Tank, Lamar
County Water Supply District, Texas
► 36" Raw Water Transmission Main, City of Paris, TeYas
► Water Treatment Plant Improvements, City of Bonham, Texas
► 150,000 Gallon Elevated Tank, City of Blossom, Texas
► 150,000 Gallon Elevated Tank, City of Emory, Texas
► 75,000 Gallon Elevated Tank and Transmission Main, City of Arp, Texas
► Raw Water Pump Station, City of Edgewood, Texas
► Raw Water Transmission main, City of Edgewood, Texas
► Water Distribution System Improvements, City of Deport, Texas
► Water Distribution System Improvements, City of Farmersville, Texas
► Water Distribution System Improvements, City of Emory, Texas
► Water Distribution System Improvements, City of Reno, Texas
► Deep Water Well, Hickory Creek S.U.D
► Transmission Main Improvements, Hiclcory Creek S.U.D.
► 75,000 Gallon Elevated Tank, Hickory Creek S.U.D.
► Master Plan, Golden Water Supply Corporation
► Deep Water Well, Golden WSC, Texas
► Pump Station Improvements, Lamar County Water Supply District
12
► Water Treatment and Pumping Facilities, City of Point, Texas
► Water Distribution System Improvements, City of DeKalb, Texas
► Water Distribution System Improvements, City of East Tawakoni, TeYas
► Water Distribution System Improvements, City of Commerce, Texas
► Water Distribution System Improvements, City of Bonham, Texas
► Water Distribution System Improvements, Golden WSC, Texas
► Water Distribution System Improvements, Winnsboro, Texas
► Water Distribution System Improvements, Trenton, Texas
► Pumping Facilities Improvements, Bright Star-Salem SUD, Texas
► Pumping & Storage Facilities Improvements, Golden WSC, Texas
► WTP Clearwell Replacement, City of Point, Texas
► 150,000 Gallon Elevated Tanlc & Transmission Main, City of East
Tawakoni, Texas
► Transmission Main Improvements, Lamar County WSD, Texas
► 0.5 Million Gallon Ground Storage Tanic, Lamar County WSD, Texas
► Water Distribution System Improvements, City of Winnsboro, Texas
STREET AND ROAD PAVING
► Paving and Drainage Improvements, City of Avery, Texas
► Paving and Drainage Improvements, City of Deport, Texas
► Paving and Drainage Improvements, City of DeKalb, Texas
► Paving and Drainage Improvements, City of Roxton, Texas
► Paving and Drainage Improvements, City of Cooper, Texas
► Paving and Drainage Improvements, Meadow Addition, City of DeKalb,
Texas
► Paving and Drainage Improvements, City of Commerce, Texas
► Paving and Drainage Improvements, City of Trenton, Texas
► Paving and Drainage - New Paris High School, Paris, Texas
TRANSPORTATION ENHANCEMENT PROJECTS
► Heritage Square Sidewalk Replacement, City of Cooper, Texas
► Downtown Sidewalk Beautification, City of Paris, Texas
► Trail de Paris, City of Paris, Texas
13
DATE (1'A~Orf"T7
cA,~► 8/14/2008
CERTIFICATE OF CERTIFICATE S UED AS A MA7TNR HE'CERT FA~ATE
' ONLY AND CONFERS NO RIGHTS UPO
AMENDEXTEND C'R
~ rSER
W
srunaon ~aeurance Ageacy, LLP HOLDER. THIS CERTIFICATE DOES NOT
eeway, Suite 220 ALTER THE COVERAGE AFFORDED BY THE POLIEIES BELO
s24o NpIC#
1212 INSURERS AFFORDING COVERAGE 37885
INSURERA XL S ecialt Ineurance Coan
INSURER B:
ineering, Znc.
INSURER C:
4445 S. E. Loop 286 INSURERD: I
paria TX 75460 INSURERE:
S OF INSURANCE LISTED BELOW ~VE BEEN ISSCTD TO THE INSURED NAMED ABOVE FOR 7HE P R~S, Y PERIOD INDICATED. NOT~N~THSTANDIN CERTIFICATE
SUCH
COVERAGES AND CO DITIONS OF ~ OR
OR OTHER DOCUMEN7 WITH RESPECT TO WHIC ~CLUSIONS
THE POLICIE
ANY REQUIREMENT, TERM OR CONDITION OF ANY CONT
MAY LIC ESTAGGREG TE L M TS SHOWN RDED MAYB AVE BEEN RIEDUCED SY PAID CLAIMS. SUBJECT TO ALL THE ~~MiTs
pOLICY
O
..,~o nnn•t pOLiGY NUMBER EFFECTIVE POLICY EXPIRATION FACH OCCURRENCE S
ERAL LIABILITY
COMMERCIAL GENERAL LIABIIITY
7 CLAIMS MADE 0 OCCUR
LIMIT APPLIES PER:
AUTOMOBILE LIABIUTY
ANY AUTO
ALL OWNED AUTOS
SCHEDULED AU705
HIRED AUTOS
NON-OWNED AUTOS
GARAGE LIA6ILITY
ANY AUTO
~ EXCESSlUMORELLA LIABILITY
I OCCUR ~ CLAIMS MADE
H DEDUCTIBLE
RETENTION S
WORKERS COMPENSATION AND
EMPLOYERS' UABILITY
PECUTIVE
ANY FFICERlMEMER EXCLUDED7
O
f~ F OTHER Profaesional Liab.
It
I
MED EXP (M one person)
PERSONAL 8 ADV INJURY S
IGENERALAGGREGATE s
I oanni iCTS - COMPfOP AGG $
dent)
LS ED SINGLE I.IMIT S
INJURY 5
son)
INJURY S
cident)
RTY ~AMAGE _
cident)
ONLY • EA ACCIDENT S
EA ACC S
R THAN
ONLY: AGG S
S
DPR9613828 8/10/2008 I 8/10/2009
.L. EACH ACCIOENT s
:.L. Dl_g~E _ EA EMPlOYE $
_.L. DISEASE - POIICY LIMIT S
$2,000,000 Per Claim/
Annual Agg=egate
DESCRIPTION OF OPERAT10N5 ! LOCAT10N5/ VEHICLES I EXCLUSIONS ADDED 8Y ENDORSEMENT 1 SPECIAL PROVISIONS
The claime mada profeaaional liability coverage ie tha total aggregate limit for all claime
preeented within the annual policy period and is aubject to a deductible.
I CH
L:
Mastar Certificata
:ANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLJCIES BE CANCELLED BEFORE TME E%P~~n~
10 DAYS W~~N
pq7E THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL o $HALL
N071CE TO T1iE CER7IFICATE NOLDER NAMED TO THE LEFT, BUT FAILURE TO DD 5
IMPOSE NO OBUGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR
AUTHORIZED REPRESENTA7NE
O ACORD CORPORATION 1988
~ ACORD 25 (2001108)
Page 1 of 2
DATE (MMlDDIYWI)
ACORD,. CERTIFICATE OF LtABILITY INSURANCE 8/14/2008
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION
RODUCER ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE
McLaughlin Brunaon Ineurance Ageacy, LLP HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR
660o LBJ Freeway, Suite 220 ALTER THE COVERAGE AFFORDED BY THE POLIEIES BELOW.
Dallas TX 75240 '
(214) 503-1212 INSURERS AFFORDING COVERAGE NAIC #
, INSURERA: XL S ecialt Ineurance Com an 37885
VSURED
Eiayter Hagineering, Znc. INSURERB:
INSURER C:
4445 S. E. Loop 286 INSURER~:
Parie TX 75460 INSURER E:
. . . . TA AIl111.1!_
.vvr.rcr+vca - - -
THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED A
MAY PERTARN, THE INSURANCE A~FORDED BY THE PO~ CIE3 DE~CR~BED HEREIN S SUB ECT TO ALL THE~ E M'S, EXCLUSIONS AND CO D T ONS OF SUCH
POLICIES. AGGREGAT E U M I T S S H O W N M A Y H A V E B E E N R EDUCED BY PAID pLA'MY EFFECTIVE POUCY EXPIRATION uMirs _
GENERAL LIABILITY
COMMERCIAL GENERAL LIABILITY
CLAIMS MADE F-IOCGUR
GEN'L AGGREGATE lIM1T APPLIES PER:
I POUCY n JEG LOC
AUTOMOHILE LIA8ILITY
ANY AUTO
ALL OWNED AUTOS
SCHEDULED AUTOS
HIRED AUTOS
NON-0WNED AUTOS
~ CLAIMS MADE
FDEDUCTIBLE A LIABILITY
RETENTION S ~IAIU-
S COMPENSATION AND E.L. EACH ACCIDEN7 S
ERS' LIABILITY
MPLOYE S
PRIETORIPARTNER/EXECUTiVE E.l. DISEASE - EA E
/MEMBER EXCLUDED7
suibe under E.L. OISEASE - POLICY LIMIT S
PROVISIONSbelow g/10/2008 B/10/2009 $2,000,000 Pflr Claim/
Profeseional Liab. DPR9613828 Annual Aggregate
EL
DESCRIPTION OF OPERA710N5 f LOCATION51 VEHICLES 1 EXCLUSIONS ADDED BY ENDORSEMENT / SPECIAL PHOVISlONS
The
presented ewimade thin Ptheeannual 1policy liability for all claima
. u..'n-`~...'. Ea~occurencs a
PREMISES
MED EXP (M one person)
S
PERSONAL & ADV INJURY
S
GENERALAGGREGATE
$
, • RRODUCTS•COMPIOPAGG
$
COMBINED SINGLE LIMIT
j
(Ea accident)
BODILY INJURY
S
(Per person)
BODILY INJURY
t
(Per accident)
PROPERTY DAMAGE
S
(Per accidenl)
AUTO ONLY - EA ACCIDENT
3
07HER THAN EA ACC
E
I AUTO ONLY: AGG
S
S
5
b
CERTIFiCAT
~:ANCELLATION
SHOULD ANY OF 7HE ABOVE DESCRIBED POUCIES BE CANCELLED BEFORE THE EXPIRATION
DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAY$ WRITTEN
NOTICE TO THE CERTFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO 00 50 SHALL
IMPOSE NO OBUGATION OR LIABILM OF ANY KIND UPON 7HE INSURER, ITS AGENTS OR
REPRESENTATIVES.
AUTHORIZED REPRESENTATiVE
r- ----r-
O ACORD CORPORATION 1988
Master Certificate
ACORD 25 (2001105)
Fee Proposal
SERVICE
FEE
$458.00
tion
t
$2,104.00
Setting
nity
$g,998.00
3
Exsng Treatment Facilities s
ti
$3 p20.00
4
Future service area and population
relationship of the plant to the service area
hi
$2,517.00
0
5
c
Physiograp
$1,903.0
6
Future influent data (design loading)
$1,219.00
7
Future permit trends
$lq 39g.00
8
Overview of site alternatives
$21,368.00
9
Process alternatives SUBTOTAL
$55,985.00
Reimbursable expenses $3,800.00
GRAND TOTAL $59,785•00
L~
1-
I
15
■
AGREEMENT FOR PROFESSIONAL SERVICES
This AGREEMENT is entered into by the City of Paris, a home-rule municipal corporation
hereinafter called " CITY," and HAYTER ENGINEERING, INC., a Texas corporation, acting herein
through a duly authorized officer, herein called "ENGINEER," because OWNER desires
ENGINEER'S services in connection with engineering services for a Master Wastewater Treatment
Plan.
WITNESSETH:
For the mutual promises and benefits herein described, the parties agree as follows:
1. Term of AGREEMENT: This AGREEMENT shall become effective on the day it is
executed, and shall continue in effect thereafter until the services provided for herein have
been performed, or until terminated as provided herein.
2. Services to be Performed bv ENGINEER: Engineer sha11 diligently and timely perform the
services described in the Scope of Services attached hereto and incorporated herein by
reference as Exhibit A. OWNER may request additional services of any type normally
rendered by ENGINEER. These will be called "Additional Services," and compensation shall
be determined as per Section 3(b) hereof.
Basic services during the construction period, if any such services are included in this
AGREEMENT, are understood to be for the time of completion initially specified in the
corresponding construction contract, and services beyond that time, including services as
expert witness or assisting in litigation, or services due to failure of the CONTRACTOR to
complete on time, will be deemed additional services.
3. Compensation of ENGINEER: Owner shall pay ENGINEER as follows:
(a) Master Wastewater Treatment Plan completed per Exhibit A and Scope -
Compensation of ENGINEER shall be per Exhibit B Fees.
(b) CITY shall pay ENGINEER for additional services requested by OWNER, at the
hourly rates on Exhibit C hereto, plus reimbursable expenses.
(c) ENGINEER may submit monthly statements for basic and additional services. These
will be based upon ENGINEER' S estimate of services completed at the time, and
OWNER shall make prompt payments. If OWNER fails to pay ENGINEER within
sixty (60) calendar days of the receipt of ENGINEER' S statement, the amounts due
ENGINEER shall increase at the rate of one percent (1 a month. ENGINEER may,
after giving seven (7) days written notice to OWNER, suspend services until paid.
EXHIBIT a
(d) In the event of termination by OWNER, ENGINEER shall be entitled to payment for
services rendered through receipt of termination notice.
(e) "Reimbursable expenses" include, but aze not limited to, long distance telephone,
postage, equipment, expendables, mileage, subcontractors or special consultants,
freight, testing fees, copies, and blueprints. Where special consultants or
subcontractors are used as additional services, the ENGINEER' S reimbursement
shall include a service charge equal to 5% of the subcontractor's invoice amount.
4. Services to be Performed bp OWNER: OWNER sha11: (i) designate a specific person as
OWNER's representative; (ii) provide ENGINEER with any previous studies, reports, data,
budget constraints, special OWNER requirements, or other pertinent information known to
OWNER; (iii) ensure access for the ENGINEER to properties necessary for performance of
the ENGINEER' S work; (iv) provide legal, accounting, or insurance consultants, financial
advisors or other similar specialists as required for the project; (v) make prompt payments in
response to ENGINEER' S statements; and (vi) respond in a timely fashion to requests from
the ENGINEER. ENGINEER is entitled to rely upon and use, without independent
verification and without liability, all information and services provided by OWNER or
OWNER's appointees, or with respect to buried utilities, the utility providing service in the
project area.
5. Termination: The obligation to provide further services under this AGREEMENT may be
terminated by either party upon ten (10) calendar days written notice, in the event of
substantial failure by the other party to perform in accordance with the terms hereof.
6. Reuse of Documents: All documents prepared by ENGINEER are instruments of service for
the specific project contemplated under this AGREEMENT. They are not intended for reuse
on extensions of that proj ect, or on any other proj ect. Any reuse without written verification
or adaptation by ENGINEER for the specific purpose intended will be at OWNER's sole risk
and without liability to ENGINEER.
7. Notices: Any notices to be given hereunder by either party to the other may be effected
either by personal delivery, in writing, or by registered or certified mail.
8. Sole Parties and Entire AGREEMENT: This AGREEMENT shall not create any rights or
benefits to anyone except the OWNER and ENGINEER, and contains the entire agreement
between the parties. Oral modifications to this agreement shall have no force or effect.
9. Texas Law to Applv; Successors; Construction: This AGREEMENT shall be construed
under and in accordance with the laws of the State of Texas. It shall be binding upon, and
inure to the benefit of, the parties hereto and their representatives, successors and assigns.
Should any provisions in this AGREEMENT later be held invalid, illegal or unenforceable,
they shall be deemed void, and this AGREEMENT shall be construed as if such provision
had never been contained herein.
2
10. Other Provisions: The parties hereto further agree as follows:
(a) Indemnification. ENGINEER shall release, defend, indemnify and hold CITY and
its officers, agents and employees harmless from and against all damager, injuries
(including death), claims, property damages (including loss of use), losses, demands,
suits, judgments and costs, including reasonable attorney's fees and expenses, in any
way arising out of, related to, or resulting from the services provided by ENGINEER
and to the extent caused by the negligent act or omission or intentional wrongful act
or omission of ENGINEER, its officers, agents, employees, subcontractors, licensees,
invitees or any other third parties for whom Engineer is legally responsible
(hereinafter "Claims"). ENGINEER is expressly required to defend CITY against all
such Claims.
In its sole discretion, CITY shall have the right to approve defense counsel to be
retained by ENGINEER in fulfilling its obligation hereunder to defend and indemnify
CITY unless such right is expressly waived by CITY in writing. CITY reserves the
right to provide a portion or all of its own defense; however, CITY is under no
obligation to do so. Any such action by CITY is not to be construed as a waiver of
Engineer's obligation to defend CITY or as a waiver of ENGINEER's obligation to
indemnify CITY pursuant to this Agreement. ENGINEER shall retain CITY
approved defense counsel within seven (7) business days of CITY's written notice
that CITY is invoking its right to indemnification under this Agreement. If
ENGINEER fails to retain counsel within such time period, CITY shall have the right
to retain defense counsel on its own behalf, and ENGINEER shall be liable for all
costs incurred by CITY.
(b) Any opinion of the probable construction cost prepared by the ENGINEER represents
only his judgment as a design professional and is supplied for the general guidance of
the OWNER. Since the ENGINEER has no control over the cost of labor and
material, or many other factors, the ENGINEER does not imply nor guarantee the
accuracy of such opinions. If the OWNER elects to redesign or rebid the project to
reduce costs, ENGINEER' S services for such rebidding or redesign shall be
additional services.
(c) The ENGINEER has not been retained or compensated to provide design and
construction review services relating to any construction contractor's safety
precautions or to means, methods, techniques, sequences, or procedures required for
the contractor to perform his work, but not relating to the final or completed
structure. The ENGINEER does not in any manner guarantee the performance of the
construction contractors.
(d) ENGINEER will strive to perform services hereunder in a manner consistent with
that level of care and skill ordinarily exercised by members of the profession
currently practicing in the same locality under similar conditions. No other
3
representation, express or implied, and no warranty or guarantee is included or
intended in this AGREEMENT, or in any report, opinion, document, or otherwise.
(e) Delivery of Electronic Files - In accepting and utilizing any drawings, reports and
data on any form of electron media from the ENGINEER, Owner agrees that such
files are instruments of service of the ENGINEER, solely for this particular Project.
The Owner agrees not to reuse these electronic files for any purpose other than of the
Proj ect. The Owner agrees to waive all claims against the ENGINEER resulting from
any unauthorized changes to or reuse of the electronic files for any other project.
Electronic files furnished by either party shall be subject to an acceptance period of
sixty (60) days. After the acceptance period, the electronic files shall be deemed to be
accepted and neither party shall have any obligation to correct errors or maintain
electronic files.
In the event of a conflict between the hard-copy construction documents and record
drawings prepared by the ENGINEER and the electronic files, the signed and sealed
hard-copy construction documents shall govern.
In addition, the OWNER agrees, to the fullest extent permitted by law, to indemnify
and hold harmless the ENGINEER, its officers, directors, employees and
subconsultants against all damages, liabilities or costs, including reasonable
attorneys' fees and defense costs,.
(f) Independent Contractor. ENGINEER covenants and agrees that ENGINEER is an
independent contractor and not an officer, agent, servant or employee of CITY; that
ENGINEER shall have exclusive control of and exclusive right to control the details
of the work performed hereunder and all persons performing same, and shall be
responsible for the acts and omissions of its officers, agents, employees, contractors,
subcontractors and consultants; that the doctrine of respondeat superior shall not
apply as between CITY and ENGINEER, its officers, agents, employees, contractors,
subcontractors and consultants, and nothing herein shall be construed as creating a
partnership or joint enterprise between CITY and ENGINEER.
(g) No Assignment. ENGINEER covenants and agrees that during the term of this
agreement, the services to be provided hereunder remain the sole responsibility of
ENGINEER, and that ENGINEER shall not during the term of this agreement assign,
subcontract, or in any other way authorize or retain other parties to provide such
services without the express written consent of CITY.
(h) Venue. The parties agree that the laws of the State of Texas shall govern this
Agreement, and that all aspects of this Agreement are performable in Lamar
County, Texas. Exclusive venue for any claim or lawsuit arising out of or related
to this Agreement shall lie in Lamar County, Texas.
4
11. Amendments to this contract shall be in writing, and be signed by the appropriate authorized
parties for both OWNER and ENGINEER.
IN WITNESS WHEREOF, the parties, having read and understood this AGREEMENT, have
executed such in duplicate copies, each of which shall have full dignity and force as an original, on
the 26th day of May , 2009.
ENGINEER: HAYTER ENGINEERING, INC. OWNER: CITY OF PARIS
By:
By:
Kevin Carruth, City Manager
ATTEST:
(Corporate Seal)
ATTEST:
Janice Ellis, City Clerk
(Seal)
5
Exhibit A
SCOPE OF SERVICES
The completed plan will be presented as a bound, written report which will identify the current
wastewater treatment capabilities and future treatment needs of the City, and develop location
and design parameters for expanded facilities. The report will include necessary maps and
drawings in multiple copies as needed. The project will begin in April of 2009, and the finished
report will be delivered by April, 2010. Presentations to the Council or staff will be included as
necessary.
The plan will include information as follows:
1. Introduction.
2. Communitv Settin . A description of Paris and Lamar County, to include data which may
be of use in developing new treatment facilities. Typical information would include
historical growth trends, industrial makeup, climatological data, soils information, air and
water quality, and base mapping.
3. Existing Treatment Facilities. This section would include a history of the plant. The
existing treatment plant was deeded to the City in the 1950's as the US Army
decommissioned Camp Maxey. The plant was upgraded in 1971 and in the 1980's. The
City's permit was originally for a secondary treatment limit, which has been enhanced
over the years as environmental constraints increase. Historical influent data will be
tabulated to show trends and to develop a consistent estimate for the strength of the waste
which must be treated. Historical effluent data would be tabulated to show the range of
flows and the efficacy of the existing treatment process. The plant components would be
analyzed to show the capacity of each under current standards, which will allow
identification of "weak links" in the current process.
The master lift station also dates to the City's acquisition of the plant from the US Army.
This section of the report would include overflow and outage history, as well as
maintenance history on the existing facility, and a condition analysis.
Finally, this section would include a summary of observations from interview with the
current operating staff.
1
4. Future service area and population. This section of the report will develop future
population estimates, in particular utilizing work done by the Pat Mayse Study
Committee for future population and water demands. Consideration will be given to the
City's historic growth trends to develop an idea of the future wastewater treatment service
area.
5. Physiographic relationship of the plant to the service area. The existing treatment plant
owes its location to its original development by the US Army to serve Camp Maxey.
Subsequently the plant was transferred to the City of Paris for a nominal sum, which
made it cost-effective to construct the original 5-mile outfall main from the City to the
plant. The plant location has remained the same since the outfall main and lift station
were existing. The master lift station is now in need of serious rehabilitation and/or
replacement, and the existing plant site is substantially occupied by existing structures. It
may be feasible to move the plant closer to the community, or further down Pine Creek.
This section would explore the pros and cons of relocating the plant to different areas
considering the ultimate service area developed earlier in the report.
6. Future influent stren h. City staff collects data regarding the strength, quantity, and
various constituents of the incoming wastewater. An industrial pretreatment ordinance
penalizes industries which contribute waste which differs significantly from the normal
domestic waste. The report would develop a recommendation for the future wastewater
quality which should be used for design of the treatment facilities.
7. Future permit trends. In the late 1970's when the plant was originally developed, the
TCEQ permit required approximately 85% reduction in BOD and TSS parameters. In
subsequent permits these limits were tightened to require 90% removal, and then 95%
removal, of the BOD. In addition to the original parameters the State now limits ammonia
nitrogen in the discharge as well as pH and dissolved oxygen. This portion of the report
would involve contact with the TCEQ permit team to determine any future permit
parameters which may need to be considered in the treatment process.
8. Overview of site alternatives. In this section the scenarios which appear likely after
consideration of paragraphs 1 through 7 would be compared. These may include a)
remodeling the existing plant; b) construct a new plant at the existing site; c) construct a
new plant downstream along Pine Creek; d) construct a new plant in some other drainage
basin; e) sludge disposal needs; and f) power requirements for each alternative and access
during flooding.
9. Once site alternatives have been evaluated, process alternatives will be evaluated. It is
likely that the City will remain with some variation of an "activated sludge" process, but
the various types can involve different pretreatment options, tankage aeration systems,
and other options. A series of alternatives would be considered both for the wastewater
itself, and far sludge processing. Preliminary layouts for each of these alternatives would
be developed, together with life-cycle cost projections.
2
All of the above would be compiled into a written report with illustrations as necessary. The
draft report would be reviewed with the plant staff and be amplified or revised as necessary to
address their concerns. The draft report would be reviewed with the City Council and a final
report would be developed.
3
Exhibit B
Fee Proposal
SERVICE
FEE
Introduction
$45 8.00
Community Setting
$2,104.00
Existing Treatment Facilities
$8,998.00
Future service area and population
$3,020.00
Physiographic relationship of the plant to the service area
$2,517.00
Future influent data (design loading)
$1,903.00
Future permit trends
$1,219.00
Overview of site alternatives
$14,398.00
Process alternatives
$21,368.00
1
2
3
4
5
6
7
8
9
SUBTOTAL $55,985.00
Reimbursable expenses $3,800.00
GRAND TOTAL $59,785.00
4
EXHIBIT C
Schedule of Per Diem Rates
March 2009
Personnel Hourly Rates
Principals
140.00
Project Managers
115.00
Project Engineer
80.00
Intern Engineers
75.00
Senior Technicians
68.00
CAD Technician
45.00
Draftsmen
27.00
Administrative Assistant
42.00
Environmentalist
50.00
On-Site Observer
45.00
Surveyor
85.00
Survey Technician
40.00
Survey Crew - 2 Man Party
85.00
Survey Crew - 3 Man Party
125.00
This Schedule of hourly rates may be modified by the ENGINEER at his discretion. Time billed for