Loading...
14-Deliberate and possibly act on an Ordinance of the City Council of the City of Paris amending Sections 7-16 and 7-18 of Article IICITY COUNCIL AGENDA ITEM BRIEFING SHEET Submittal Date: Originating Department: Presented By: Agenda Item No.: 08/19/10 Planning & Zoning Shawn Napier, P.E., Director of Council Date: Commission Engineering, Planning and 14. 08/23/10 Develo ment RECOMMENDED MOTION: [NOT AN ACTION ITEM - FIRST READING] IF SUPERMAJORITY RULE INVOKED - Move to approve an ordinance amending Sections 7-16 and 7-18 of Article II, Building Code, Chapter 7, Buildings and Building Regulations of the Code of Ordinance of the City of Paris, Texas to adopt the 2006 International Building Code, the 2006 International Existing Building Code, 2006 International Residential Code, and the 2008 National Electrical Code, as amended herein as the Official Building, Residential, Existing Building and Electrical Codes. POLICY ISSUE(S): Public Safety BACKGROUND: Although the City has never formally adopted the 2003 International Building Code (IBC), we have been following it because it was mandated by the State of Texas. The IBC contains fire code provisions, some of which conflict with the City's adopted 1994 Standard Fire Code. This and other deficiencies and inconsistencies in our codes makes it difficult for builders to know what the City's expectations are, potentially adds unnecessary costs to projects, and can lead to buildings that are not as safe as they can be. Recognizing the need to modernize the code and improve safety, staff began researching and developing an updated fire code and ardinance in 2007. On August 24, 2009, Council appointed a Building and Fire Code Review Committee comprised of local builders, electrical contractors, Council Members, and city staff and charged them with reviewing the 2006 International Fire Code, Chapter 12 of the Code of Ordinances, and 2006 International building codes, with local amendments recommended by city staf£ The Committee completed their review on August 10, 2010, and recommends adoption of the changes as detailed in the accompanying ordinance. During the Committee's review, the Committee's scope expanded to include the 2008 National Electric Code and the 2006 International Existing Building Code. The Committee declined to review the 2006 International Residential Code (IRC), deferring to city staff to make recommendations to Council. The IRC brings uniformity to construction of one- and two- family dwellings and townhouses up to three stories high and brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. The accompanying handout details the major changes from the 2003 IRC to the 2006 IRBC. A deficiency with the current permitting process concerns establishing the value of the building project, utilized to determine the cost of certain permits. The current process relies upon the person applying for the permit list the project cost and requires no documentation to support the claimed value. Section 108 of the 2006 IBC states "If, in the opinion of the building official, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can show detailed estimates to meet the approval of the building official." Under the authority granted by Section 108, staff will use the International Code Council (ICC) Building Valuation Data (BVD) sheet (updated every six months), which includes square foot prices based on building types and occupancy and is a national standard. After talking to local businesses and contractors, the local construction prices for commercial projects appear to be 15% lower and the residential projects are 26% lower than the BVD for Paris. Consequently, staff will determine building project values based on the BVD standard but modified to account for the local market unless the applicant can provide documentation supporting a lower project value. City of Paris Revised 2/04/08 95 BOARD/COMMISSION RECOMMENDATION: The Fire and Building Code Review Committee recommended adopting all of the codes above with the exception of the International Residential Code, to which they deferred to city staff. EXHIBITS: Ordinance; 2006 International Residential Code changes; Building Valuation Data; Project valuation com arisons ACTION: BUDGET INFO: ❑ Financial Report ❑ Minute Order Expense $ ❑ Department Report ❑ Resolution gudgeted Amt. $ ❑ Presentation Z Ordinance y"j'D Actual $ ❑ Public Hearing ❑ Other Acct. Name Acct. Number FISCAL NOTES: REVIEWED AND APPROVED BY: Z Administrarion Z City Clerk Z Community Development ❑ EMS/IT ❑ Finance ❑ Fire ❑ Municipal Court Z Legal ❑ Library ❑ Police Z Eng./Public Works ❑ Utilities City of Paris 96 Revised 2/04/08 DRAFT attorney\ordwork\current\Amend Sec 7-16 Adopt Bldg & Electrical Codes ORDINANCE 1V0. AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF PARIS, TEXAS, AMENDING SECTIONS 7-16 AND 7-18 OF ARTICLE II, BUILDING CODE, CHAPTER 7, BUILDINGS AND BUILDING REGULATIONS OF THE CODE OF ORDIIVANCES OF THE CITY OF PARIS, TEXAS TO ADOPT THE 2006 INTERNATIONAL BUILDING CODE, THE 2006 INTERNATIONAL EXISTING BUILDING CODE, 2006 INTERNATIONAL RESIDENTIAL CODE, AND THE 2008 1VATIONAL ELECTRICAL CODE, AS AMEIVDED HEREIN AS THE OFFICIAL BUILDING, RESIDENTIAL, EXISTING BUILDING AND ELECTRICAL CODES FOR ALL CONSTRUCTION WITHIIV THE CITY OF PARIS, TEXAS; MAKING OTHER FINDINGS AND PROVISIONS RELATED TO THE SUBJECT; PROVIDING A REPEALER CLAUSE, A SEVERABILITY CLAUSE, A SAVINGS CLAUSE, A PENALTY CLAUSE; AND DECLARING AN EFFECTIVE DATE. WHEREAS, the City of Paris has not conducted a full review and update of its building, residential, fire and electrical codes in more than ten years and many of its codes are in need of revision and updating; and, WHEREAS, new and updated building, fire, residential and electrical codes are necessary to properly regulate and govern the conditions and maintenance of all property, buildings and structures; by providing the standards for supplied utilities and facilities and other physical things and conditions essential to ensure that structures are safe, sanitary and fit for occupation and use; and the condemnation of buildings and structures unfit for human occupancy and use and the demolition of such structures in the City of Paris; and, WHEREAS, the Director of Engineering, Planning and Development hereby recommends the 2006 International Building Code, 3rd Printing July 2007, the 2006 International Existing Building Code, 2°d Printing March 2008, the 2006 International Residential Code, 3rd Printing March 2007, and the 2008 National Electrical Code, as amended, as the best uniform building and electrical codes to provide uniform guidelines and regulations for all property, buildings and structures by providing the standards for supplied utilities and facilities and other physical things and conditions essential to ensure that structures are safe, sanitary and fit for occupation and use in the City of Paris, Texas; and, WHEREAS, on August 24, 2009 the City Council of the City of Paris formed a Building and Fire Code Review Committee made up of local builders, electrical contractors, City Council members and City Staff to review new building and fire codes proposed by the City Engineer, City Fire Chief and Fire Marshall; and, WHEREAS, the Building and Fire Code Review Committee has reviewed and considered the new building, existing building, fire and electrical codes and amendments as set out herein and recommends that they be approved by the City Council; and, 97 WHEREAS, the City Council deems it to be in the best interest of the City of Paris and its citizens to adopt the 2006 International Building Code, 2006 International Existing Building Code, 2006 International Residential Code and 2008 National Electrical Code as amended with local amendments as set out below. 1VOW, THEREFORE, BE IT RESOLVED BY THE CITY COUIVCIL OF THE CITY OF PARIS, TEXAS: Section 1. That the findings set out in the preamble to this ordinance are hereby in all things approved. Section 2. That Article II, Section 7-16 of the Code of Ordinances of the City of Paris shall be and is hereby amended to read as follows: "Sec. 7-16. Building Codes - Adoption (a) For purposes of this Section, the following definitions shall apply: (1) International Residential Code shall mean the 2006 International Residential Code, including any and all amendments, revisions or revised additions to the 2006 International Residential Code. (2) National Electrical Code shall mean the 2008 National Electrical Code published by the IVational Fire Protection Association, including any and all amendments, revisions or revised additions to the 2008 National Electrical Code adopted. (3) Building Code shall mean the 2006 International Building Code for, including any and all amendments or revisions thereto adopted. (4) Existing Building Code shall mean the 2006 International Existing Building Code for, including any and all amendments or revisions thereto adopted. (b) In conformance with Subchapter G, Chapter 214, Sections 214.211 through 214.214 of the Texas Local Government Code, the 2006 International Building Code shall be and is hereafter adopted as the Municipal Building Code for the Ciry of Paris. The 2006 International Building Code shall apply to the conditions and maintenance of all property, buildings and structures; by providing the standards for supplied utilities and facilities and other physical things and conditions essential to ensure that structures are safe, sanitary and fit for occupation and use; and the condemnation of buildings and structures unfit for human occupancy and use and the demolition of such structures in the City of Paris. The City Council may establish procedures to adopt local amendments to the 2006 International Building Code and for the administration and enforcement of the International Residential Code. 98 (c) In conformance with Subchapter G, Chapter 214, Sections 214.211 through 214.214 of the Texas Local Government Code, the 2006 International Existing Building Code shall be and is hereafter adopted as the Municipal Existing Building Code for the City of Paris. The 2006 International Existing Building Code shall apply to the repair, alteration, change of occupancy, addition and relocation of existing buildings, including historic buildings, in the City of Paris. The City Council may establish procedures to adopt local amendments to the 2006 International Existing Building Code and for the administration and enforcement of the International Existing Building Code. (d) In conformance with Subchapter G, Chapter 214, Sections 214.211 through 214.214 of the Texas Local Government Code, the 2006 International Residential Code shall be and is hereafter adopted as the Municipal Residential Building Code for the City of Paris. The 2006 International Residential Code shall apply to all construction, alteration, remodeling, enlargement, and repair of residential structures in the City of Paris. The City Council may establish procedures to adopt local amendments to the International Residential Code and for the administration and enforcement of the International Residential Code. The International Residential Code shall not apply to the installation and maintenance of electrical wiring and related components. (e) In conformance with Subchapter G, Chapter 214, Sections 214.211 through 214.213 of the Texas Local Government Code, the 2008 National Electrical Code shall be and is hereafter adopted as the Municipal Electrical Construction Code for the City of Paris. The 2008 National Electrical Code shall apply to all electrical construction applications within the City of Paris. The City Council may establish procedures to adopt local amendments to the National Electrical Code and for the administration and enforcement of the National Electrical Code. (o Copies of the 2006 International Building Code, 2006 International Existing Building Code, 2006 International Residential Code, and the 2008 National Electrical Code will be maintained on file in the Office of the City Engineering, Planning and Development Department and the City Public Library, and the provisions thereof shall be controlling as set out herein in the construction of all buildings and other structures within the corporate limits of the city of Paris, Texas." Section 3. That Article II, Section 7-18 of the Code of Ordinances of the City of Paris shall be and is hereby amended to read as follows: -99 "Sec. 7-18. Same - Amendments. The codes adopted by Section 7-16 are hereby amended as set out in this section: The 2006 International Building Code, the 2006 International Existing Building Code and the 2006 International Residential Building Codes are amended as follows: Section 113 Violations Section 113.4 Violation penalties, is hereby amended to read as follows: A person who shall violate a provision of this Code or who fails to comply herewith or with any of the requirements hereof, or who shall erect, construct, alter or repair, or who has erected, constructed, altered or repaired a building or structure in violation of a detailed statement or plan submitted and approved hereunder, or of a permit or certificate issued hereunder, shall be guilty of a misdemeanor and, upon conviction, shall be fined in any sum not to exceed two thousand dollars ($2,000.00) for violations affecting fire safety, zoning or public health and sanitation and not exceeding five hundred dollars ($500.00) per violation in all other cases; and each and every day's continuance of any violation of the provisions of this Code shall constitute and be deemed a separate offense. The 2006 International Building Code is amended as follows: AppendixA, Employee Qualifications, is deleted. Appendix H, Signs, is deleted. Appendix K, ICC Electrical Code, is deleted." Section 4. That all provisions of the ordinances of the City of Paris, Texas in conflict with the provisions of this ordinance are hereby repealed, and all other provisions of the ordinances of the City of Paris not in conflict with the provisions of this ordinance shall remain in full force and effect. Section 5. That the repeal of any ordinance or part of ordinances affected by the enactment of this ordinance shall not be construed as abandoning any action now pending under or by virtue of such ordinance or as discontinuing, abating, modifying, or altering any penalty accruing or to accrue, or as affecting any rights of the municipality under any section or provisions of any ordinance at the time of passage of this ordinance. Section 6. That it is the intention of the City Council of the City of Paris that this ordinance, and every provision hereof, shall be considered severable, and the invalidity or partial invalidity of any section, clause, or provisions of this ordinance shall not affect the validity of any other portion of this ordinance. Section 7. That any person violating any provision of this ordinance shall be guilty of a Misdemeanor, and upon conviction, shall be subject to a fine in accordance with provisions of Sec. 1-6 of Chapter One of the City of Paris Code of Ordinances, and each and every day's continuance 100 of any violation of the above-enumerated sections shall constitute and be deemed a separate offense. Section 8. That by a supermajority vote of ayes and nays, the City Council voted to suspend the rule requiring two readings before adoption of this ordinance. Section 9. That this ordinance shall become effective from and after its passage of the first reading and publication as required by law. PASSED AND ADOPTED on first and final reading this 23rd day of August, 2010. Will Biard, Mayor ATTEST: Janice Ellis, City Clerk APPROVED AS TO FORM: W. Kent McIlyar, City Attorney 101 2006 international Residential Code° The City of Paris is proposing to adopt the 2006 International Residential Code. This handout will summarize the major changes in the 2006 IRC compared to the 2003 IRC. 1. Table R301.5 now requires the design live load on the bottom chord of engineered roof trusses to be 20 psf instead of the typical 10 psf when there are two or more adjacent trusses with the same web configuration capable of containing a rectangle 42 inches high or greater by 24" wide or greater, measured between the top of the bottom chord and bottom of any truss member; and provided that the attic area is accessible by a pull down stairway or framed opening in accordance with Section R807.1, and the truss has bottom chord pitch less than 2: 12. This may result in some trusses being designed for bottom chord loads differently than other trusses. It is the responsibility of builder to verify this before the frame inspection (before trusses are set). 2. Section R302.1 and Table R302.1 now requires that the minimum fire separation distance (distance from the exterior wall to the property line) shall be 5 feet in order for the exterior wall to be non fire-resistance rated. If the exterior wall is closer than 5' to the property line, it will need to be one hour fire-resistance rated (fire rated wall assembly tested from both sides). Projections, such as eaves or soffits, shall not extend more than 12" into the area where openings are prohibited (i.e. no closer than 2 feet to the property line); and these projections shall be one hour fire-resistance rated on the underside with no openings (i.e. no soffit vents). In the first printing of the 2006 IRC there is a discrepancy in the wording of Section R302.1 and the dimensions shown in table R302.1. The wording in the text is correct and the dimension in Table R302.1 showing 4 feet for minimum fire separation distance for projections should be 2 feet. This will be changed by errata from ICC. Penetrations in walls that are closer than 5' to property line will need to be protected in accordance with Section R317.3. This will include such items as electrical boxes for light fixtures, gas pipe entries, hose bibbs, etc. Openings in walls located from 3' to 5' from the property line are restricted to 25% maximum of the wall area and allowed to be unprotected. Openings in walls less than 3' from the property line are prohibited. The City of Paris, subdivision set back requirements will not allow a residence to be built in closer than 5' from the lot line. Therefore, this change will not affect residential building projects. 3. 2003 Section R303.6.1 required the control for the mandatory stairway illumination to be accessible at the top and bottom of the stairway without traversing any steps. 2006 Section R303.6.1 deletes the language about not having to traverse any stairs and clarifies that wall switches are only required at top and bottom floor levels when the stair has six or more risers. This now corresponds with the National Electrical Code. 4. Section R308.4, exception #4 has been reworded to clarify that approved safety glazing shall be provided in a wall that is perpendicular to the plane of a door if the 102 door swings towards this wall. This will now match the requirements in the IBC. 5. New Section R310.5 clarifies that when an emergency escape window (for bedroom or sleeping room) is located under a deck or porch the window shall be able to be fully opened and a path not less than 36" high shall be provided to a yard or court. This is a life safety issue. 6. Section R311.4.3 was changed to clarify requirements for landings at exterior doors. The major change in this section is that door landing slopes are now regulated. They will need to have a slope that does not exceed 2%. This applies to any exterior door. 7. Section R319.1.5 now requires that glued-laminated timbers exposed to the weather and not properly protected by a roof, eave, or similar covering be pressure treated with preservative, or be manufactured from naturally durable or preservative-treated wood. 8. Section R323 was added to give guidance on requirements for elevators and platform lifts. This gives us direction to ASME A17-1(the elevator code). 9. Section R408.3 now gives direction for "unvented" craw) spaces. 10. Section R613.2 now requires that where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located. Glazing between the floor and 24 inches shall be fixed or have openings through which a 4 inch diameter sphere cannot pass. This will also apply to windows that are directly above a basement window well. 11. Section R702.4.2 now requires the use of cement, fiber cement, or glass mat gypsum backers behind wall tile in tub and shower areas and behind wall panels in shower areas. Moisture resistant drywall (green board) is no longer acceptable in these areas. 12. Section R703.4 now requires that, in areas where the basic wind speed is 110 mph or higher, attachment of exterior siding meet the component and cladding loads specified in Table R301.2(2), adjusted for height and exposure in accordance with Table R301.2(3). The contractor shall verify the fastening requirements with the manufacturer for all wall coverings. This will not affect the City of Paris, as we are not in the areas addressed in Table R301.2(2). 13. Table 703.4 now requires approved water resistive barriers behind all siding materials. 14. Chapter 11(Energy Efficiency) has been revised in its entirety. Please also see the handout for the 2006 Energy Codes. One of the bigger changes is that Table N1102.1 will require the exterior wall insulation to be R-19 or R-13 with an R-5 insulated sheathing covering the exterior. There is an exception that allows the R-5 to be reduced to R-2 if structural sheathing covers more than 25% of the exterior. This will effectively not allow a 2 X 4 wall with the typical R-13 unless there is additional R-2 or 143 R-5 insulated sheathing added. Instaliing R-15 within the wall without the insulated Sheathing will not be approved since the intent is to have the insulated sheathing completely cover the entire wali framing. This applies for buildings using the prescriptive method of compliance. Builders will be able to use the performance method of compliance if they choose. This could consist of using a Home Energy Rating Service (HERS), which will check the overall performance of the house including appliances, insulation, and tightness of house. The HERS contractors also typically do blower door tests for the house and an air test to check for leakage in the ductwork. These tests are performed by approved third party companies and complete documentation shall be submitted to the Building Division. These are the Department of Energy requirements for energy efficiency. When builders complete a RESCHECK this information will be required as a minimum standard. 104 The International Code Council is pleased to provide the following Building Valuation Data (BVD) for its members. The BVD will be updated at six-month intervals, with the next update in August 2010. ICC strongly recommends that all jurisdictions and other interested parties actively evaluate and assess the impact of this BVD table before utilizing it in their current code enforcement related activities. The BVD tabie provides the "average" construction costs per square foot, which can be used in determining permit fees for a jurisdiction. Permit fee schedules are addressed in Section 109.2 of the 2009 International Building Code (IBC) whereas Section 109.3 addresses building permit valuations. The permit fees can be established by using the BVD table and a Permit Fee Multiplier, which is based on the total construction value within the jurisdiction for the past year. The Square Foot Construction Cost table presents factors that reflect relative value of one construction classification/occupancy group to another so that more expensive construction is assessed greater permit fees than less expensive construction. ICC has developed this data to aid jurisdictions in determining permit fees. It is important to note that while this BVD table does determine an estimated value of a building (i.e., Gross Area x Square Foot Construction Cost), this data is only intended to assist jurisdictions in determining their permit fees. This data table is not intended to be used as an estimating guide because the data only reflects average costs and is not representative of specific construction. This degree of precision is sufficient for the intended purpose, which is to help establish permit fees so as to fund code compliance activities. This BVD table provides jurisdictions with a simpfified way to determine the estimated value of a building that does not rely on the permit applicant to determine the cost of construction. Therefore, the bidding process for a particular job and other associated factors do not affect the value of a building for determining the permit fee. Whether a specific project is bid at a cost above or below the computed value of construction does not affect the permit fee because the cost of related code enforcement activities is not directly affected by the bid process and results. Building Valuation The following building valuation data represents average valuations for most buildings. In conjunction with IBC Section 109.3, this data is offered as an aid for the building official to determine if the permit valuation is underestimated. Again it should be noted that, when using this data, these are "average" costs based on typical construction methods for each occupancy group and type of construction. The average costs include foundation work, structural and nonstructural building components, electrical, plumbing, mechanical and interior finish material. The data is a national average and does not take into account any regional cost differences. As such, the use of Regional Cost Modifiers is subject to the authority having jurisdiction. Permit Fee Multiplier Determine the Permit Fee Multiplier: 1. Based on historical records, determine the total annual construction value which has occurred within the jurisdiction for the past year. Determine the percentage of the building department budget expected to be provided by building permit revenue. Permit Fee Multiplier = Total Annual Construction Value Bldg. Dept. Budget x Example The building department operates on a$300,000 budget, and it expects to cover 75 percent of that from building permit fees. The total annual construction value which occurred within the jurisdiction in the previous year is $30,000,000. Permit Fee Multiplier = $300,000 x 75% = 0.0075 Permit Fee $30,000,000 The permit fee is determined using the building gross area, the Square Foot Construction Cost and the Permit Fee Multiplier. Permit Fee = Gross Area x Square Foot Construction Cost x Permit Fee Multiplier Example Type of Construction: IIB Area: 1 st story= 8,000 sq. ft. 2nd story = 8,000 sq. ft. Height: 2 stories Permit Fee Multiplier = 0.0075 Use Group: B 1. Gross area: Business = 2 stories x 8,000 sq. ft. = 16,000 sq. ft. 2. Square Foot Construction Cost: B/IIB = $140.34/sq. ft. 3. Permit Fee: Business = 16,000 sq. ft. x$140.34/sq. ft x 0.0075 _ $16,841 10 5 Building Valuation Data - February 2010 Important Points The BVD is not intended to apply to alterations or repairs to existing buildings. Because the scope of alterations or repairs to an existing building varies so greatly, the Square Foot Construction Costs table does not reflect accurate values for that purpose. However, the Square Foot Construction Costs table can be used to determine the cost of an addition that is basically a stand-alone building which happens to be attached to an existing building. In the case of such additions, the only alterations to the existing building would involve the attachment of the addition to the existing building and the openings between the addition and the existing building. • For purposes of establishing the Permit Fee Multiplier, the estimated total annual construction value for a given time period (1 year) is the sum of each building's value (Gross Area x Square Foot Construction Cost) for that time period (e.g.> 1 year). The Square Foot Construction Cost does not include the price of the land on which the building is built. The Square Foot Construction Cost takes into account everything from foundation work to the roof structure and coverings but does not include the price of the land. The cost of the land does not affect the cost of related code enforcement activities and is not inciuded in the Square Foot Construction Cost. Square Foot Construction Costs a, b. d I Grou 2009 International Buildin Code 1A 1B 2A 2B 3A 3B 4 SA 5B A-1 Assembl , theaters, with sta e 204.81 197.86 192.77 184.35 172.91 168.11 177.81 158.10 151.39 A-1 Assembl , theaters, without sta e 187.37 180.42 175.33 166.91 155.51 150.71 160.37 140.70 133.99 A-2 Assembl , ni htclubs 155.74 151.36 147.50 141.90 133.46 129.73 136.94 121.02 116.96 A-2 Assembl , restaurants, bars ban uet halls 154.74 150.36 145.50 140.90 131.46 128.73 135.94 119.02 115.96 A-3 Assembl churches 189.22 182.27 177.18 168.76 157.33 152.53 162.22 142.51 135.80 A-3 Assembl , eneral, communit halls, libraries, museums 158.87 151.92 145.83 138.41 125.97 122.17 131.88 111.16 105.45 A-4 Assembl , arenas 186.37 179.42 173.33 165.91 153.51 149.71 159.37 138.70 132.99 B Business 158.40 152.65 147.57 140.34 127.30 122.71 134.52 111.91 106.66 E Educational 171.53 165.59 160.55 153.20 141.88 134.72 147.92 123.99 119.32 F-1 Facto and industrial, moderate hazard 93.92 89.61 84.47 81.69 73.14 69.92 78.41 60.23 56.97 F-2 Facto and industrial, low hazard 92.92 88.61 84.47 80.69 73.14 68.92 77.41 60.23 55.97 H-1 Hi h Hazard ex losives 88.02 83.71 79.57 75.79 68.42 64.20 72.51 55.51 N.P. H234 Hi h Hazard 88.02 83.71 79.57 75.79 68.42 64.20 72.51 55.51 51.25 H-5 HPM 158.40 152.65 147.57 140.34 127.30 122.71 134.52 111.91 106.66 1-1 Institutional, su ervised environment 159.09 153.50 148.95 142.51 130.74 127.30 138.80 117.44 112.84 I-2 Institutional, hos itals 266.39 260.64 255.56 248.33 234.50 N.P. 242.51 219.11 N.P. I-2 Institutional, nursin homes 185.59 179.83 174.76 167.53 154.81 N.P. 161.71 139.41 N.P. 1-3 Institutional, restrained 180.47 174.72 169.64 162.41 150.60 145.01 156.59 135.20 127.96 1-4 Institutional, da care facilities 159.09 153.50 148.95 142.51 130.74 127.30 138.80 117.44 112.84 M Mercantile 115.80 111.42 106.56 101.96 93.15 90.42 97.00 80.71 77.65 R-1 Residential, hotels 160.44 154.84 150.29 143.85 132.24 128.80 140.31 118.95 114.35 R-2 Residential, multi le famil 134.26 128.66 124.11 117.67 106.72 103.28 114.78 93.42 88.82 R-3 Residential, one- and two-famil 124.88 121.41 118.43 115.31 111.07 108.19 113.40 104.09 97.95 R-4 Residential, care/assisted livin facilities 159.09 153.50 148.95 142.51 130.74 127.30 138.80 117.44 112.84 S-1 Stora e, moderate hazard 87.02 82.71 77.57 74.79 66.42 63.20 71.51 53.51 50.25 S-2 Stora e, low hazard 86.02 81.71 77.57 73.79 66.42 62.20 70.51 53.51 49.25 U Utilit , miscellaneous 68.13 64.29 60.15 56.88 50.70 47.41 54.03 39.33 37.47 a. Private Garages use Utility, miscellaneous b. Unfinished basements (all use group) _$15.00 per sq. ft. c. For shell only buildings deduct 20 percent d. N.P. = not permitted 1OF Project Valuation Comparisons Submitted Actual Fee Avg. Paris Proposed Sample Location Sq. Ft. Valuation Charged ICC Valuation Valuation Fee . • 41 4/sq.ft.; Average Paris • 111 Ray's Place-609 N Main 2400 $70,000.00 $345.00 $336,816.00 $288,000.00 $1,029.00 Dollar General-2300 N. Main 9014 $329,380.00 $1,153.14 $1,265,024.76 $1,081,680.00 $2,828.36 Armstrong McCall-3060 Lamar Ave 3650 $333,786.00 $1,166.35 $512,241.00 $438,000.00 $1,479.00 Sandwhic Etc.-3070 Lamar Ave 4200 $210,000.00 $795.00 $589,428.00 $504,000.00 $1,673.00 Residential • A • Paris • : 11 Pshigoda 4 Plex 4307 $225,000.00 $840.00 $496,640.17 $366,095.00 $1,263.29 5100 Amherst Court 3016 $210,000.00 $795.00 $347,774.96 $256,360.00 $934.08 200 44th SW 1968 $90,000.00 $425.00 $226,930.08 $167,280.00 $666.84 Total Commercial & Residential Fees ~ ~ . ~ > $5,519.49 $9,873.57 107