1563 ORD AMENDING ORDINANCE NO 1074 ORDINANCE NO 1202 ORDINANCE NO 1508ORDIlVANCE NO. 1563 . AN OR,DINANCE AMENDING ORDINANCE NO. 1074, ORI?INANCE NO. 1202, AND ORDINANCE NO. 1508; PROVIDING FOR A PERMIT FOR THE INSTALLATION OF A SEPTIC TANK WITHIN THE CITY OF PARIS, TEXAS; PROVIDING FOR THE CONSTRUCTION ACCORDING TO PLANS AND SPECIFICATIONS; PROVIDING FOR INSPECTION; AND PROVIDING FOR THE VIOLATION OF SAID OR.DINANCE OR ANY SEC- TION THE RE OF. PA RIS: BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF Section 1. That no person, firm or corporation, their agents, servants or employees, shall insta.ll any septic tank within the corporate limits of the City of Paris, Texas, without the owner or contractor, and/or plumber having obta.'ined a permit to insta.ll the same from the Plumbing Inspector of the City of Paris, Texas. Section 2. That all septic ta,nks shall be of the following design: The minimum size tank to be used shall ha.ve at least 1 foot of air space above the flow line. The ta,nk, or ta,nks, shall be large enough to hold the sewage produced for a period of 48 hours to nhta.in the maxi- mum reduction in solids. The tank may be rectangular or round. For efficient operation in the use of recta.ngular ta,nks the length should be at least twice, but not over three times, as great as the width. The depth of the tank may vary, depending on local economic `and terrain conditions; however, the depth should be at least 30 inches to the flow line. The tank shall be constructed of corrosive-resista.nt, impervious material and strong enough to withsta,nd the soil and hydrosta,tic loads encountered. The pipe from the house to the tank shall be of case iron material and in sta,lled with watertight joints, and there shall be a cleanout connection on this line. Multiple compartments, or ta.nks in series, may be used if the economics of the installation make this procedure attractive to the owners. The compartments shall be connected at least 12 inches below the top of the liquid level, and the connection may be accomplished by using slots, plain-end pipes, or elbow joints. If multiple compartments or tanks in series are used, each com- partment or tank shall be not less than 125 gallon capacity,, and the first unit shall be as large or larger than the following units.' In the . absence of data regarding the quantity of sewage which will be produced per day, in case no special conditions exist, the sewage flow figures listed in Table No. 1 may be', used, I ~ TABLE I Gallons per day Type of Esta.blishment per person Home s 50 Hotels 75 Motels (without Kitchens) 40 Motelq or cottages with kitchens 50 Restaurants (per person served) 7 Trailer Parks with central bathhouse 35 Trailer Parks with individual baths 50 Camps with central bathhouses 50 Luxury Camps 75 Day Schools 15 Hospitals 150 Park Rest Stations 5 Park Bath Houses 10 Servicea Stations, (Per vehicle served) 10 If the service facilities such as garbage grinders, washing ma- chines, etc., are to be served, the design should be increased 50% for each such facility; that is, for a home without special facilities the de- sign basis would be 50 gallons per capita per day, and if a washing ma- chine or garbage grinder is to be used the design would be 75 gallons per capita per day, and if a washing machine and garbage grinder are installed the design basis would be 100 gallons per capita, per day. The tank inlet and outlet shall be protected from clogging by the scum by the use of either 'Teetz connections or baffles. The 'Tee" or baffles , shall extend 12 inches below the liquid surface, and if the baffle is used it shall extend 6 inches or more above the liquid surface. PIain-end pipe may be used if baffles are provided. If 'Tees"ake used the inlet 'Tee't shall have the top plugged to prevent tank gases entering the house line, and thus escaping to the house plumbing. The outlet 'Tee" shall be screened at the tope with corrosion-resista.nt material to prevent scuxn overflow entering the effluent line. Elbow fitting will not be permitted. Section 3. All drainage field lines shall be designed and constructed after a percolation test has been made and approve'd by the Plumbing Inspector. The porosity of the soil shall be deterxnined by excavating a hole one foot square and of a depth equal to that at which it is proposed to lay the tile drain. The hole to be filled with water to insure thorough moistening of the soil and allow the water to seep away. Then while the bottom of the hole is still moist, fill to a depth of six inches and observe the time required for the water level to fall one inch. The approximate length of tile required per person based upon a trench 12 inches wide and a sewage flow of fifty gallons per capita per day, is given as follows: TABLE II Time for water to fall 1 inch in Minute s 2 3 4 5 10 15 30 60 Over 60 Approximate length in feet of 4" tile in 1 foot-wide trench for 50 gallons per day 25 30 35 40 50 65 90 120 Unsuita,ble The minimum length of open joinx drainage tile shall not be less than 150 feet, even though soil tests indicate fewer feet of drainage field would suffice. The effluent main from the septic tank shall be not less than 4-inch ti3;e , and it shall be a watertight line with a fall of 1 inch per 100 feet. The open joint laterals shall be laid on a grade of 1 inch fall per 100 feet, and each lateral shall not exceed 50 feet. The open joint lines shall be laid on top of a bed of gravel not less than 4 inches thick, and the gravel cover shall be not less than 2 inches over the tile. The 1-foot joints of the tile shall be laid with opening 1/4 inch between tiles, and the upper half of the joints shall be covered with a tar paper or other ma- terial which will prevent soil silting into the pipe and thus closing it. The gravel used in drainage trenches shall pass a screen h.aving 2 1/2- inch opening but be reta.ined on a screen having 1/2-inch openings. For accuracy of grades, the levels should be checked by an experienced operator using a farm level or better. instrument, and this requirement is especially importa,nt for insta.llations which exceed 150 feet of open joint drainage tile. The lateral trenches shall be at leasti 8 feet apart. If the site and equipment are conducive to the use of trenches which are wider than 1 foot, the installation will be accepta.ble provided the laterals are kept spaced in accordance with Table No. III. TABLE IIT Width of Gravel-filled Trench 12 inches 18 inches 24 inches Over 24 inches Minimum spacing between laterals 8 feet 10 feet 12 feet 5 time s trench width The laterals are spaced in accordance with the flow to minimize the overlapping of zones of influence. The length of tota.l absorption trench may be decreased provided the tota.l square foota,ge of trench bottom is not decreased below that de- termined by using the percolation test and interpreting the results in accordanee with Table No. II above. Section 4. That no person, firm or cornoration, their agents, servants or employees, shall ever cover any drainage system until same has been inspected by and approved by the Plumbing Tnspector. Section 5. No person, firm or corporation, their agents, servants or employees, shall ever install a septic ta,nk closer than 50 feet to a water well, and shall never install any drainage field lines which are closer to a water well than 150 feet. Section 6. Upon the appli,cation for a permit for the insta,llation of any septic tank, a fee of $3. 00 will be charged for the inspection by the City Plumbing Inspector, which inspection will include the witness of the percolation test and the insta,llation of the complete septic ta,nk. Section That any person, firm or corporation who shall fail to comply with, or shall violate any of the provisions of this ordinance, shall be deemed guilty of a misdemeanor, and upon conviction thereof, ahall be fined in any sum not exceeding Two Hundred ($200. 00) Dollars- for each offense, and each day that any person, firm or corporation shall mainta.in upon premises owned, occupied or controlled by them, a condi- tion that is in violation of any provision of this ordinance, shall be deemed a separate offense. Section 8. All ordinances and parts of ordinances in conflict herewith are hereby repealed. Section 9. The effective date of this ordinance shall be the 28th day of September, A. D., 1961. Passed and adopted this llth day of September, A. D., 1961. C. ATTEST: " Mayor City Clerk APPROVED AS O FORM: . I~c~L