17 Parr-Hull Preliminary PlatMEMORANDUM
TO:
FROM:
DATE:
Mayor and City Council
Planning and Zoning Commission
Shawn Napierk'~l,~
City Engineer~
October 3, 2002
SUBJECT: Preliminary Plat of Parr-Hull Medical Plaza and Commercial Center Unit
One
I have reviewed the preliminary plat of the above referenced addition. It appears that the plat
complies with the City of Paris subdivision regulations with the following exceptions and/or
additions.
4.
5.
6.
The engineer or surveyors name is needed on the preliminary plat.
A preliminary drainage plan is required, that shows proposed structures and
drainage-ways with acres by class to be drained for the preliminary plat and
master plat.
Show the building lines per the requested zoning.
A 10-foot utility easement is required along the West boundary line with U.S. 271
Right-of-Way.
Add a note on both plats that the developer shall install all sewer and water
services.
Remove the lift station and associated force main on the master plat. Submit a
preliminary plan to gravity flow the sewer to the outfall line adjacent to Stillhouse
Creek.
I recommend approval of the preliminary plat upon completion of the above items.
CCi
Michael E. Malone, City Manager
Larry W. Schenk, City Attorney
Steve Methven, Building Official