09 Parr-Hull-Prelim PlatJNIT ~ LO( 4 MEMORANDUM TO: FROM: DATE: Mayor and City Council Planning and Zoning Commission Shawn Napier, P.~/~ City Engineer ~)1 ~ October 30, 2003 SUBJECT: Preliminary Plat of Parr-Hull Medical Plaza and Commercial Center Unit One I have reviewed the preliminary plat of the above referenced addition. It appears that the plat complies with the City of Paris subdivision regulations with the following exceptions and/or additions. When gravity sewer becomes available the owner of Lot 1 shall tie to the sewer line at the owners expense. Lot 1 will use the existing private force main that was installed with Murray's Mis-Q (now Garden Restaurant). The parmership that is developing Parr-Hull also owns the Garden Restaurant and force main. Lot 1 will be required to install the same horsepower pump that is at the Garden Restaurant. The development on Lot 1 will need to size the pump tank to accommodate expected water usage. I recommend approval of the preliminary plat upon completion of the above items. Michael E. Malone, City Manager Larry W. Schenk, City Attorney Steve Methven, Building Official David Wood, P.E., Landmark Consultants, Inc.