My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06 - MINUTES FROM VARIOUS BOARDS, COMMISSIONS, AND COMMITTEES
City-of-Paris
>
City Council
>
Agenda Packets
>
2011-2020
>
2016
>
10 OCTOBER
>
10/24/2016
>
06 - MINUTES FROM VARIOUS BOARDS, COMMISSIONS, AND COMMITTEES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2016 1:38:29 PM
Creation date
10/20/2016 1:20:56 PM
Metadata
Fields
Template:
AGENDA
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEXAS STATE FIRE MARSHAL'S OFFICE <br />FIRE SAFETY INSPECTION REPORT <br />FACILITY <br />INSPECTION NUMBER <br />DATE OF INSPECTION <br />INSPECTOR <br />1St National Bank <br />David J. Alarid <br />8004 Two Coves Drive <br />Austin, Texas 78730 <br />512- 476 -6900 <br />Lamar County <br />Physical Address: 104 Bonham, Paris, Texas 75460 <br />Email address: dalarid(Daustin.rr.com <br />1 sr National Bank <br />RRO 15800A <br />August 26, 2016 <br />Scott McAnallen <br />The State Fire Marshal's Office received a complaint about the safety of the 15t National Bank <br />building in Paris, Texas. A consultation was conducted and enforcement of noted violations <br />was transferred to the City of Paris Fire Marshal. <br />One building was inspected with the following violations noted in accordance with NFPA 1, Fire <br />Code and NFPA 101, Life Safety Code. <br />The 151 National Bank is a six story high rise structure with a basement and a mechanical <br />penthouse. It is classified as mixed occupancy with new assembly and new apartment <br />occupancies. Fire protection features are limited to portable fire extinguishers. The building is <br />equipped with illumined exit signs and emergency lighting units. <br />Note: There has not been any renovation of the building to be able to assess if the new <br />occupancy would meet code. Correction of the following violations are required to meet <br />minimum code requirements, however during renovations other violations could be noted. <br />VIOLATION 1 <br />The building does not have the required fire sprinkler system. <br />NFPA 1, Fire Code, Chapter 13.3.2.17.1 and 13.3.2.26.1 <br />VIOLATION 2 <br />The building does not have the required fire alarm system. <br />NFPA 1, Fire Code, Chapter 13.7.2.11.1 <br />Inspection Number RRO15800A Page 1 of 5 <br />Revised 12/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.