Laserfiche WebLink
Section 1020.1 Construction shall be amended by adding Exception 6 to read as follows: <br />1020.1 Construction. ... <br />Exceptions: <br />6. In group B occupancies, corridor walls and ceilings need not be of fire - resistive construction <br />within a single tenant space when the space is eauipped with approved automatic smoke - <br />detection within the corridor. The actuation of any detector shall activate self - annunciating <br />alarms audible in all areas within the corridor. Smoke detectors shall be connected to an <br />approved automatic fire alarm system where such system is provided. <br />Section 1029.1.1.1, Spaces under grandstands and bleachers shall be deleted in its entirety. <br />Section 1101.1 Scope, shall be amended by adding the following exception to read as follows: <br />follows: <br />1101.1 Scope: ... <br />Exception: Components of projects regulated by and registered with Architectural Barriers <br />Division of Texas Department of Licensing and Regulation shall be deemed to be incompliance <br />with the requirements of this chapter. <br />Section 1203. 1, General, shall be amended to read as follows: <br />1203.1 General. Buildings shall be provided with natural ventilation in accordance with Section 1203.4, <br />or mechanical ventilation in accordance with the International Mechanical Code. <br />Where air infiltration rate in a dwelling unit is less than 5 air changes or less per hour when tested <br />with a blower door at a pressure 0.2 inch w.c. (50 Pa) in accordance with Section 402.4.1.2 of the <br />International Energy Conservation Code, the dwelling unit shall be ventilated by mechanical means in <br />accordance with Section 403 of the International Mechanical Code. <br />Table 1505. 1, Minimum Roof Covering Classification For Types of Construction shall be amended <br />to delete footnote c in its entirety and to replace footnote b to read as follows: <br />b. Non - classified roof coverings shall be permitted on buildings of U occupancies having not more than <br />120 sq. ft. of protected roof area. When exceeding 120 sq. ft. of protected roof area, buildings of U <br />occupancies may use non -rated non - combustible roof coverings. <br />s. [delete] <br />Section 1505.7, Special purpose roofs, shall be deleted in its entirety. <br />Section 1511. 1, General, shall be amended to read as follows, with the text of the Exception to <br />remain unchanged: <br />1511.1 General. Materials and methods of applications used for recovering or replacing an existing roof <br />covering shall comply with the requirements of Chapter 15. All individual replacement shingles or shakes <br />shall be in compliance with the rating required by Table 1505.1. <br />{Text of the Exceptions remain unchanged.} <br />Section 1704.2, Special inspections and tests, is amended to read as follows: <br />1704.2 Special inspections and tests. Where application is made to the Building Official for construction <br />as specified in Section 105, the owner or the owner's authorized agent, or the registered design <br />professional in responsible charge, other than the contractor, shall employ one or more approved <br />13 2015 IBC Amendments <br />