My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020-051 - Amendments to Section 7-18 of Article II Building Code Chapter 7 - Buildings and Building Regulations - Revise the Local Amendment sot the 2015 International Building Code and the 2015 International Residential Code
City-of-Paris
>
City Clerk
>
Ordinances
>
2011-2020
>
2020
>
2020-051 - Amendments to Section 7-18 of Article II Building Code Chapter 7 - Buildings and Building Regulations - Revise the Local Amendment sot the 2015 International Building Code and the 2015 International Residential Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2020 12:27:37 PM
Creation date
10/13/2020 12:23:55 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
provides personal care services. The occupants are capable of responding to an emergency situation <br />without physical assistance from staff. <br />Section 202, DEFINITIONS, shall be amended to amend the definition of ATRIUM to read as <br />follows: <br />ATRIUM. An opening connecting twe three or more stories... {Balance remains unchanged) <br />Section 202, DEFINITIONS, shall be amended to add the definition of REPAIR GARAGE to read as <br />follows: <br />REPAIR GARAGE. A building, structure or portion thereof used for servicing or repairing motor vehicles. <br />This occupancy shall also include garages involved in minor repair, modification and servicing of motor <br />vehicles for items such as lube changes, inspections, windshield repair or replacement, shocks, minor part <br />replacement and other such minor repairs. <br />Section 202, DEFINITIONS, shall be amended to amend the definition of SPECIAL INSPECTOR to <br />read as follows: <br />SPECIAL INSPECTOR. A qualified person employed or retained by an approved agency who shall prove <br />to the satisfaction_ of the registered desigwn . rofessional in resconslble charge and approved by the Building <br />Official as having the competence necessary to inspect a particular type of construction requiring special <br />inspection. <br />Section 202, DEFINITIONS, shall be amended to amend the definition of HIGH-RISE BUILDING to <br />read as follows: <br />HIGH-RISE BUILDING. A building with an occupied floor located more than 7-5 55 feet ( 22 860 mm) 16 764 mm <br />above the lowest level of fire department vehicle access. <br />Section 303.9.3, Associated with Group E Occupancies, shall be amended to read as follows: <br />303.1.3 Associated with Group E occupancies. A room or space used for assembly purposes that is <br />associated with a Group E occupancy is not considered a separate occupancy.- Except when applying the <br />assembly requirements of Chapter 10 and 11. <br />Section 304. 1, Business Group B, shall be amended to add the following to the list of <br />occupancies: <br />Fire stations <br />Police stations with detention facilities for 5 or less <br />Section 307.1.9, Uses other than Group H, shall be amended by amended subsection 4 to read as <br />follows: <br />4. Cleaning establishments that utilize combustible liquid solvents having a flash point of 140°F (60°C) or <br />higher in closed systems employing equipment listed by and approved testing agency, provided that this <br />occupancy is separated from all other areas of the building by 1 -hour fire barriers constructed in <br />accordance with Section 707 or 1 -hour horizontal assemblies constructed in accordance with Section 711 <br />or both. See also IFCmCha ter 21 Dry Cleaning _Plant provisions; <br />Section 403. 1, Applicability, shall be amended by amending Exception 3 to read as follows: <br />3. The 9p air portion of a building containing a Group A-5 occupancy in accordance with Section <br />303.6. <br />Section 403.3, Automatic Sprinkler System, shall be amended to delete Item 2 of the Exception.. <br />Section 403.3.2, Water supply to required fire pumps, shall be amended to read as follows: <br />[F] 403.3.2 Water supply to required fire pumps. In buildings that are more than 428120feet (36.5 mi <br />in building height, required fire pumps shall be supplied by connections to no fewer than two water mains <br />located in different streets. Separate supply piping shall be provided between each connection to the <br />2015 IBC <br />Amendments <br />
The URL can be used to link to this page
Your browser does not support the video tag.