Laserfiche WebLink
1. Four stories or less above grade plane. <br />2. The floor level of the highest story is 35 feet (10668 mm) or less above the lowest level of <br />fire department vehicle access. <br />3. The floor level of the lowest story is 35 feet (10668 mm) or less below the lowest level of <br />fire department vehicle access. <br />{No change to remainder of section.} <br />Amend Section 903.3.1.2.2, Corridors and balconies, to read as follows: <br />903.3.1.2.2 Corridors and balconies. Sprinkler protection shall be provided in all corridors and <br />for all balconies. <br />{Delete the rest of this section.} <br />Delete existing Section 903.3.1.2.3, Garages and attics, and replace with the following: <br />903.3.1.2.3 Attached garages and attics. Sprinkler protection is required in attached garages, <br />and in the following attic spaces: <br />1. Attics that are used or intended for living purposes or storage shall be protected by <br />an automatic sprinkler system. <br />2. Where fuel -fired equipment is installed in an unsprinklered attic, not less than one quick - <br />response intermediate temperature sprinkler shall be installed above the equipment. <br />3. Attic spaces of buildings that are two or more stories in height above grade plane or above <br />the lowest level of fire department vehicle access. <br />4. Group R-4, Condition 2 occupancy attics not required by Item 1 or 3 to have sprinklers <br />shall comply with one of the following: <br />4.1. Provide automatic sprinkler system protection. <br />4.2. Provide a heat detection system throughout the attic that is arranged to activate the <br />building fire alarm system. <br />4.3. Construct the attic using noncombustible materials. <br />4.4. Construct the attic using fire -retardant -treated wood complying with Section 2303.2 of <br />the International Building Code. <br />4.5. Fill the attic with noncombustible insulation. <br />Amend Section 903.3.1.3, NFPA 13D sprinkler systems, to read as follows: <br />903.3.1.3 NFPA 13D Sprinkler Systems. Automatic sprinkler systems installed in one- and two- <br />family dwellings; Group R-3; Group R-4, Condition 1; and townhouses shall be permitted to <br />be installed throughout in accordance with NFPA 13D or in accordance with state law. <br />Add Section 903.3.1.4., Freeze protection; 903.3.1.4.1, Attics; and 903.3.1.4.2, Heat trace/insulation; <br />to read as follows: <br />903.3.1.4 Freeze protection. Freeze protection systems for automatic fire sprinkler systems <br />shall be in accordance with the requirements of the applicable referenced NFPA standard and this <br />section. <br />